9 Trouble-shooting
Message
Possible cause
Solution
▪
«UX/EXX»
▪
Disruption in the
power supply.
▸ Acknowledge the error message by
touching «OK».
▸ Switch the power supply off for about
1 minute.
▸ Switch the power supply back on.
▸ If the error appears again, note down
the error message in full along with
the serial number (SN) of the appli-
ance (see page 59).
▸ Disconnect from the power supply.
▸ Contact Customer Services.
▪
«E69/A1»
▪
Temperature must
drop below 300 °C
▸ Allow the appliance to cool down.
▸ Acknowledge the error message by
touching «OK».
–
Appliance is ready for operation
again.
▪
«E24/A1» in
pyrolytic appli-
ances
▪
Door status detection
failed.
▸ Push in the door status detection
device next to the locking hook and
keep it pressed.
–
The following appears in the dis-
play: «OK».
▸ Press «OK».
▸ Push in the lever of the door status
detection device for 15 seconds. Dur-
ing these 15 seconds, the locking
hook will move.
9.2
Other possible problems
Problem
Possible cause
Solution
▪
Appliance is
not working
▪
A household fuse or
circuit breaker has
tripped.
▸ Change the fuse.
▸ Reset the circuit breaker.
▪
The fuse or circuit
breaker keeps blow-
ing.
▸ Call Customer Services.
▪
Interruption in the
power supply.
▸ Check the power supply.
▪
Demo mode is
switched on.
The demo mode can only be switched
off with the security code.
▸ Contact Customer Services.
▪
Appliance is faulty.
▸ Contact Customer Services.