background image

3 Operating the appliance

3.4 

Power level

▸ Touch the 

 button.

The next highest power level switches on. 

▸ Touch the 

 button.

The next lowest power level switches on.

The corresponding power level appears in the display.

The intensive power level cannot be selected using the 

 button.

3.5 

Intensive level

The intensive power level can run for 6 minutes. It is used for short bursts of intensive ex-
traction of cooking fumes and smells, e.g. when searing meat. The intensive power level
then switches back to the previously selected power level or switches the appliance off.

Switching on

▸ Touch the 

 button.

The appliance switches the intensive power level on for 6 minutes.

HI

 and the time remaining alternate in the display.

If another power level had been running beforehand, then the appliance will automat-
ically revert to this power level after 6 minutes has elapsed.

If no power level had been running when the intensive level was selected, the appli-
ance will switch off after 6 minutes.

Ending before time

▸ While the intensive power level is active, touch the 

 button.

The intensive level switches off before time.

The appliance switches back to the previously selected power level or switches off.

3.6 

After-running time

The purpose of the after-running time function is to remove any lingering smells after
cooking. The appliance continues to run at the power level set for 30 minutes and then
switches off automatically.

Switching on

▸ Switch the appliance on and touch the 

 or 

 button repeatedly until the desired

power level is reached.

▸ Touch the 

 button.

The after-running time function switches on and the corresponding power level ap-
pears in the display.

A dot in the display flashes once a second when the after-running time function is
active.

Ending before time

▸ Touch the 

 button again to end the after-running time function.

The after-running time function ends.

The appliance switches back to the previously selected power level.

▸ Touch the 

 button.

The appliance switches off.

11

Summary of Contents for 62019

Page 1: ...Operating instructions DIQS10 DWQS6 DWQS7 DWQS9 Range hood...

Page 2: ...a correspond to the technical standard of the appliance at the time these operating instructions went to press The right to make technical modifications for the purpose of the further development of t...

Page 3: ...for the first time 10 3 2 Switching the appliance on off 10 3 3 Illumination 10 3 4 Power level 11 3 5 Intensive level 11 3 6 After running time 11 3 7 CleanAir 12 3 8 Saturation indicator alarm 12 3...

Page 4: ...d 8 and above and by persons with reduced physical sensory or mental capabilities or lack of experi ence and or knowledge provided they are supervised or have been instructed on the safe use of the ap...

Page 5: ...d from the mains power supply to avoid pos sible electric shock When replacing a light bulb the maximum wattage rating of replaceable light bulbs must be visible This appliance is intended for use in...

Page 6: ...use The appliance is designed for use in the home for extracting cooking fumes and smells from above the cooking sur face Any repairs modifications or manipula tions to the appliance especially any el...

Page 7: ...p frying appliance could overheat and catch fire Constantly monitor the temperature of the cooking oil keeping it below the temperature at which it can catch fire Change the cooking oil regularly dirt...

Page 8: ...ith activated charcoal filter A fan extracts cooking fumes and smells from above the cooking surface The air is passed through the metal grease filter and activated charcoal filter grease particles an...

Page 9: ...ity illumination Display field 03 Power level 1 3 HI Intensive level FC Switch between extraction recirculation mode alarm for activated char coal filter on off 24 CleanAir function active FF Reset sa...

Page 10: ...s activated Setting up the appliance for use in the extraction mode Switch the appliance and the illumination off Hold the button depressed for 5 seconds FC appears in the display with a dot that flas...

Page 11: ...running when the intensive level was selected the appli ance will switch off after 6 minutes Ending before time While the intensive power level is active touch the button The intensive level switches...

Page 12: ...m Metal grease filters After 100 operating hours FG appears in the display when the appliance is switched off The saturation level has been reached and the metal grease filters must be cleaned Activat...

Page 13: ...h national regulations Activating the remote control Switch the appliance and the illumination off Hold the button on the appliance depressed for five seconds I R appears in the display with a dot tha...

Page 14: ...el Touch the button The next highest power level switches on Touch the button The next lowest power level switches on Switching intensive level on off Touch the button The intensive level switches on...

Page 15: ...rior Grease and condensate water can build up on the inside around the metal grease filters Clean using a clean damp cloth and a mild detergent or a soft brush as needed then dry well using kitchen to...

Page 16: ...the metal grease filters to become slightly discoloured How ever this will not affect the functioning of the filters in any way 4 3 Standard activated charcoal filter The standard activated charcoal...

Page 17: ...lean the activated charcoal filter in the dishwasher at max 70 C Do not use de tergent Wash separately so that no food debris can become stuck to the activated charcoal filter If no dishwasher is avai...

Page 18: ...cannot be remedied please call Customer Services Before calling Customer Services Please note down the serial number for SN see iden tification plate under Technical data and what led to the fault Mal...

Page 19: ...Long life activated charcoal fil ters Standard activated charcoal filter Remote control 7 Technical data Electrical connection Accessing the identification plate Remove the metal grease filters The id...

Page 20: ...um speed intensive or boost excluded Qmax m3 h 580 580 Air flow at intensive or boost setting Qboost m3 h 700 700 Airborne acoustical A weighted Sound Power Emissions at minimum speed SPEmin dBA 52 52...

Page 21: ...ppliance from the mains With a fixed appliance this is to be carried out by a qualified electrician Then cut the mains cable off flush with the appliance 8 3 Disposal The crossed out wheeled bin symbo...

Page 22: ...With remote control 13 Initial set up 6 Intensive level 11 With remote control 14 M Model designation 2 Model number 2 O Operating and display elements 9 Operating the appliance 10 P Product fiche 21...

Page 23: ...register your appliance You will find them on the identification plate of your appliance My appliance information SN __________________________ Appliance ________________________________ Please have t...

Page 24: ...ion Low intensity illumination Display field 03 Power level 1 3 HI Intensive level FC Switch between extraction recirculation mode alarm for activated char coal filter on off 24 CleanAir function acti...