background image

Installation instructions

Built-in variants of gas hob
Dials

1014402-R05

14/08/2019

1014402-R05

7

Thread length

Thread length of gas connection on the appliance (external thread) 

So

 is 16 mm. If the thread

length of the on-site counterpart (internal thread) 

Si

 is longer than 17 mm, the front-end seal is no

longer guaranteed through the supplied green sealing ring H64006 with a height of 1.5 mm.

In this case, the yellow sealing ring 1030096 with a height 

h

 of 5 mm is to be used as it provides a

leak tight connection for on-site thread lengths of up to 20.5 mm.

Si

So

h

½-inch conical thread

If the gas connection has a conical thread, the transition piece and sealing ring must first be
screwed onto the appliance. The transition piece has a conical external thread R ½-inch in accord-
ance with ISO 7/11. In the case of a conical screw connection, the thread makes the seal, which is
why the thread must be sealed with hemp or Teflon tape.

After the gas has been connected, leak and function testing must be carried out by a registered gas fitter.

Conversion to another gas type

The appliance is set up for a certain gas type, which is also recorded on the identification plate. The appliance can be converted to an-
other type of gas using the nozzle sets supplied (others available as accessories). This requires the burner injector nozzles and the gas
tap bypass nozzles be changed.
All the nozzles are numbered to avoid any mix-up.
Always disconnect the appliance from the electricity and gas mains before changing the nozzles.

Changing the injector nozzles

Remove the pan supports and burners.

It is also necessary to remove the nozzle cover flap if the hob has a wok burner.

Remove central injector nozzles (using 7 mm socket wrench).

Remove horizontal injector nozzles in the wok burner using an open-end wrench.

Screw in the new injector nozzles (according to the table) as far as they will go.

It is necessary to put back the nozzle cover flap if the hob has a wok burner.

Changing the bypass nozzles

Pull all control knobs up and off.

Loosen all the screws in the burner plates (torx no. 10) and then remove the burner plates.

Remove the drawers or cabinet front to gain access from below.

Flush mounted

Surface mounted

A

Remove all the nuts from around the circumference of
the appliance (using 8 mm socket wrench).

A

Loosen any adjusting braces and lift gas hob up and out
of the cut-out.

B

Supporting the appliance tray with one hand, unscrew
the two knurled nuts in opposite corners.

B

Remove lateral screws from around the circumference
of the appliance (torx no. 20).

C

Let the appliance tray slide down and remove from the
kitchen cabinet.

C

Lift the base plate upwards and carefully remove from
the base.

Remove the springs and microswitch from the gas taps.

Remove the bypass nozzle from each gas tap and screw in the new nozzle as far as it will go.

Caution! The wok gas tap has two bypass nozzles, both of which must be changed.

Put back the microswitch and springs.

Summary of Contents for 31075 Series

Page 1: ...r low voltage installations and fire protection must be strictly observed All leak tests should be done with a soapy water solution Never use an open flame to check for leaks All leak tests should be...

Page 2: ...surface mounted combination of several hobs 1019199 Flush installation Designation Article no Steel angle set hob size 60 H63772 Designation Art no Instant adhesive for installation of the steel angle...

Page 3: ...face to the underside of the gas connection Ri Corner radii of appliance for base plate Ra Outer corner radii of cut out S Minimum distance between the top of the work surfaces and any drawer T Minimu...

Page 4: ...iance for base plate Ra Outer corner radii of cut out S Minimum distance between the top of the work surfaces and any drawer T Minimum distance between the cut out in the back and any drawer Installat...

Page 5: ...es with basic insulation must not be accessible Check old installa tions Refer to the identification plate for information on the required mains voltage current type and fuse protection The connection...

Page 6: ...meters above sea level a re duced performance must be expected Gas connection The gas connection and the conversion to another gas type must be carried out by an authorized installer 51 46 GAS641 51...

Page 7: ...ll the nozzles are numbered to avoid any mix up Always disconnect the appliance from the electricity and gas mains before changing the nozzles Changing the injector nozzles Remove the pan supports and...

Page 8: ...After the nozzles have been changed leak testing must be carried out and then the flame pattern checked in the min max position for each burner Nozzle table Change injector nozzles using a 7 inch sock...

Reviews: