Installation instructions
«Front loader» washing machine
One-family household
1064372-11
19/10/2022
1064372-11
6
Setting up the water inlet
Local water authority regulations must be observed.
Any old water supply and drain hoses must always be replaced with new hoses.
Only cold water G¾” permitted, possible pressure range: 0.1–1.0 MPa (1–10 bar).
The appliance must not be connected to a mixer tap or a continuous flow boiler!
Preferred alignment for Aquastop valve block
1
(sound-optimized install-
ation):
▸
Tap seal seat must be clean and flat.
▸
Install hose without kinking or twisting it.
▸
Check the seal.
1
Plumbing in
When installing the drain hose, protect it against damage and kinks!
Drainage into fixed upright outflow pipe
▸
Fit drain hose
2
using hose clamp
1
and rubber connection piece
3
.
▸
Shorten drain hose
2
to necessary length.
▸
Mount hose support
4
near but not to the appliance – e.g. on a wall or
hook.
▸
Do not exceed the maximum pumping height (≤1200)!
≤120
0
≥350
4
2
1
2
3
ø 28,0
ø 21,5
1500
Drainage into a bath tub or sink, etc.
▸
Fit drain hose
2
using hose clamp
1
and rubber connection piece
3
.
▸
Drain hose
2
must not be shortened!
▸
Mount hose support
4
near but not to the appliance – e.g. on a wall or
hook.
▸
Fix hose end with hose support
4
.
▸
Do not exceed the maximum pumping height (≤700)!
≤700
2
4
Positioning and levelling the appliance
To ensure fault-free operation, the appliance must stand level with all 4 feet firmly on the installation plate and not
wobble.
▸
Roughly adjust the height of the front and rear adjuster feet using
socket wrench (size 10). Height adjustment: ≤14 mm (1.5 mm per
turn)
▸
Use a spirit level
1
to level the appliance.
▸
Slide the appliance onto the installation plate.
▸
Finely adjust the height of the front adjuster feet.
▸
Use a spirit level
1
to level the appliance.
▸
The appliance must not wobble!