Setting
Item
L E D
state
Description
Default
Ring volume
3-rx
Set volume for call tone,rang from 0~9.
6
Speaker volume
4-Lx
Set volume for speaker,adjust the voice from
outdoor,rang from 0~9.
6
Microphone
volume
5-tx
Set volume for microphone,adjust the voice from
user,rang from 0~9.
6
Numbers of door
station
6-0x
Maximum 4 door stations can be selected,this
item is used to set the numbers of door station
that can be surveilled by indoor monitor.refer to
part 2 ->Entrance Monitoring.
1
Numbers of
indoor monitor
7-xx
Maximum 32 indoor monitors can be selected,this
item is used to set the numbers of indoor monitor
that can be selected to intercom.refer to part 2
->Intercom call.
04
Keypad sensitivity 8-sx
Rang from 0~2,The larger you set the value,the
stronger it will be,"0"-slow,"1"-normal,"2"-fast.
1
Slave adress
setting for monitor 9-dx
Rang from 0~3,"0"-master monitor,"1~3"-slave
monitor.
0
Restore to default
setting
9-FS
The restore to default function allows the user to
recover the settings to factory setting.Select "9-
FS" item on LED,then press Up button,"YES"will
be asked,press Up button again to restore the
settings to default.
-
4. Specification
●
Power Supply:
DC24V
●
Power Consumption:
standby 20mA,working 70mA
●
7 segment LED:
4 digits dynamic
●
Wiring:
2 wires, non-polarity
●
Dimension:
187(H)X97(W)X33(D)mm
The design and specifi cations can be changed without notice to the user. Right to interpret and copyright of this manual are preserved.