background image

PRODUCT DESCRIPTION 
   

  The infrared (IR) controller is easy to connect and operate for the RGB Strip Light, with an advanced chip in it. 

It has various static colors and light patterns that allow you to set your favorite color and with dim control. 
 

TECHNICAL PARAMETERS 

Working temperature

 

-20-60

 

Supply voltage

 

12V

24V optional

 

0utput

 

3 channels

 

Connecting mode

 

common anode

 

 

Static power consumption 

<1W

 

Output current 

<2A(each channel) 

Output power 

12V:<72W,    24V:<144W 

 
DIRECTION FOR USE   

 

Connect the load wire at first, followed by the power wire. 

 

Operation: you will receive infrared remote control in front of infrared receiver to ensure that there is no 
barrier between the remote controller and receiver. 
The key-press functions are shown in the table as below (in accordance with the key position order):   

Brig 

Brightness - 

Off 

On 

Static red 

Static green 

Static blue 

Static white 

Static rose red 

Static light green 

Static sapphire blue 

3 color jumpy change 

Static dark yellow 

Static cyan blue 

Static violet and grey  3 color fade change 

Static Orange 

Static sky blue 

Static pink 

7 color fade change 

Static yellow 

Static cyan 

Static purple 

7 base color jumpy 

 

CONNECTION 

 
Application Circuit: 

 

 

SPECIAL REMARK 

This product has a special adjustable line sequence function (adjusting with BRG, GRB or RGB). If you discover that 
the light color with the remote control button is not matching, you can mobilize it using below steps:   

(a)

 

Ensure that the controller is connected properly. 

(b)

 

Press OFF button and then press SMOOTH. The light will FLASH once. 

(c)

 

Press ON button and check if the remote control button and the light color are matching. If not, repeat the 
above step (b), till you get the correct output. 

 

CAUTIONS 

1. Supply voltage of this product is DC12V~24V. Never connect to any other voltage.   
2. Before using the infrared remote, the insulating film should remove. 
3. Lead wire should be connected correctly according to grade that connecting diagram offers. 
4. This product is not to overload; 

Reviews: