4. The mounting surface should be
perpendicular to the horizontal line
as shown in the figure below.
Please install the inverter vertically
or tilted back ≤15° to facilitate the
heat dissipation of the machine.
Do not tilt the inverter forward,
horizontally, upside down, lean
back too much, or install it
sideways.
1. Place the hanging plate at the wall installation point, adjust the angle with a horizontal
ruler, and mark with a marker pen
2. Punch holes with a impact drill and install expansion bolts. The user needs to prepare
the expansion bolt by himself, and it is recommended to use M8 x 60 stainless steel
explosion expansion bolt.
3. Fixed hanging plate. Clean the hole, impact the expansion bolt into the hole with a
rubber hammer, use a wrench to tighten the nut to fix the tail of the bolt, then remove the
nut, spring pad and flat pad, and then lock the wall hanging plate fixation to the wall
surface, with the tightening torque of 13Nm.
INVERTER INSTALLATION