4. The mounting surface should be 

perpendicular to the horizontal line 

as shown in the figure below. 

Please install the inverter vertically 

or tilted back ≤15° to facilitate the 

heat dissipation of the machine. 

Do not tilt the inverter forward, 

horizontally, upside down, lean 

back too much, or install it 

sideways.

1. Place the hanging plate at the wall installation point, adjust the angle with a horizontal 

ruler, and mark with a marker pen

2. Punch holes with a impact drill and install expansion bolts. The user needs to prepare 

the expansion bolt by himself, and it is recommended to use M8 x 60 stainless steel 

explosion expansion bolt.

3. Fixed hanging plate. Clean the hole, impact the expansion bolt into the hole with a 

rubber hammer, use a wrench to tighten the nut to fix the tail of the bolt, then remove the 

nut, spring pad and flat pad, and then lock the wall hanging plate fixation to the wall 

surface, with the tightening torque of 13Nm.