If the terminal of the ward has a very low power and needs to be powered off, the terminal of the ward will
automatically upload one piece of low-voltage alarming command to the monitoring center number.
9.
9.
9.
9. Set
Set
Set
Set APN
APN
APN
APN Command
Command
Command
Command
Create
Create
Create
Create the
the
the
the SMS
SMS
SMS
SMS “
“
“
“802#APN
802#APN
802#APN
802#APN letters
letters
letters
letters or
or
or
or digits,
digits,
digits,
digits, 4-20
4-20
4-20
4-20 bits
bits
bits
bits #
#
#
# Log
Log
Log
Log user
user
user
user name
name
name
name letters
letters
letters
letters or
or
or
or digits
digits
digits
digits 4-20
4-20
4-20
4-20 bits
bits
bits
bits in
in
in
in #
#
#
#
Log
Log
Log
Log password
password
password
password letter
letter
letter
letter or
or
or
or digits
digits
digits
digits 4-20
4-20
4-20
4-20 bits
bits
bits
bits in
in
in
in #
#
#
# terminal
terminal
terminal
terminal password
password
password
password 4
4
4
4 bits
bits
bits
bits ##
##
##
##”
”
”
” and
and
and
and send
send
send
send it
it
it
it to
to
to
to the
the
the
the terminal;
terminal;
terminal;
terminal; after
after
after
after
executing
executing
executing
executing this
this
this
this command,
command,
command,
command, the
the
the
the terminal
terminal
terminal
terminal will
will
will
will automatically
automatically
automatically
automatically restart
restart
restart
restart and
and
and
and connect
connect
connect
connect to
to
to
to
GPRS with APN set.
Command example 1: #802#cmnet###0000##
#
#
#
#
Command example 2: #802#CCDLEN#QIUXIA.21#RX0000#0000##
After this command is executed, APN will be CCDLEN; the login user name is QIUXIA.21 and login
password is RX0000.
Note:
Note:
Note:
Note: The
The
The
The default
default
default
default APN
APN
APN
APN of
of
of
of this
this
this
this product
product
product
product is
is
is
is CMNET.
CMNET.
CMNET.
CMNET.
10.
10.
10.
10. Electronic
Electronic
Electronic
Electronic Fence
Fence
Fence
Fence Function
Function
Function
Function
(1)GPS
(1)GPS
(1)GPS
(1)GPS Fence
Fence
Fence
Fence Function
Function
Function
Function
The guardian may log into the system, click the custom deviation setup in the user system manager, enter
the deviation setup interface, choose the longitude and latitude of the center point to be set as fence. Click the
mouse in the Google map, then reading page will display the electronic fence with longitude and latitude set.
Set fence format: # command number (751) # fence radius # sampling interval # longitude # latitude #
user password ##.
For example: #751#500#5#22.5442N#113.91E#0000##
After the setup is successful, the setting mobile phone will receive a piece of config ok command. Then,
when the ward leaves this area, the terminal will send the alarming information of being out of the fence to the
center number.
(2)GSM
(2)GSM
(2)GSM
(2)GSM Fence
Fence
Fence
Fence Function
Function
Function
Function
The ward may send # command number (740) user password 4 digits ## command to set the GSM
fence. After the setup is successful, the terminal will return the message of CONFIG OK to the setting
mobile phone, or the message of PASSWORD ER if the password is wrong.
For example:
#740#0000##
Description of GSM fence: The terminal reads the GSM base station information, including that the main
base station and the adjacent base stations. Take the first four digits and keep them in the module. If the
base station has many data with different first digits, they all must be saved. And initiate the protection
status. In the state of protection, the module will read the data of all base stations (1-7) once every 5
minutes, and take the first 4 digits to compare with the protection data. If all the first 4 digits of the data of
all base station are consistent with the existing data, then dial or send alarming messages to the user
according to the alarming setup.
For example: #740#0000##. After the fence is set, the terminal will alarm in the case where it is moved
about 3-5km out of the fence.
(3)
(3)
(3)
(3) Fence
Fence
Fence
Fence Reading
Reading
Reading
Reading Function
Function
Function
Function
Send commands to the terminal: # command number (752) # user password 4 digits ##; after the
command is set successfully, the terminal will read the data of the module fence working status and return
message to the sending mobile phone, or PASSWORD ER if the password is wrong.
For example:
#752#0000##
Return: #open:1#lat:11456.209400#lng:2233.470100#distance:500#time:5#status:2
Where, open: 1 indicates fence open; Open: 0 indicates fence closed;
lat:11456.209400, latitude;
lng: 2233.470100; longitude;