background image

ShenZhen V-Sun Electronics Co., Ltd 

 20

2.4 Set up the access point name of GPRS

   

Format 1

#803#user password#APN## 

eg

#803#0000#CMNET## 

Format 2

#803#user password#APN#APN user name#APN password ## 

Explanation 1

: Different GSM / GPRS service associations provide different 

APN, please according to local service providers to provide the APN to choose 

format 1 or 2 to use set.     

 

Explanation 2

: When v-sun 680 tracker receives the instruction and confirms 

the user password correctly, updates the access point name to the new access 

point name. After the success, it will send the confirmation messages to the 

sender. If sent the format 1, the content is “SET GPRS APN OK”; if it is format 2, 

the content is “SET GPRS ACCOUNT OK”. 

 

2.5 

Set up the TCP/IP server and IP’s address and port number 

Format

#804#user password#fixed IP address # port ##   

eg

#804#0000#222.125.12.32#80## 

Explanation

: When v-sun 680 tracker receives the instruction and confirms the 

user password correctly, updates the IP address and port number preserved in 

the module

After the success, it will send the confirmation messages to the 

sender. The content is “SET SERVER IP AND PORT OK” 

 

2.6 

Upload the location instruction at once   

Format

#806#user password##   

eg

#806#0000## 

Explanation:

 When v-sun 680 tracker receives the instruction and confirms the 

user password correctly, sends the confirmation messages to the sender. The 

content is “START GPRS UPLOAD”. At the same time, send the data from the 

memory block to server. 

Summary of Contents for V680

Page 1: ...V680 WATCH GPS TRACKER User s Manual V1 0 ...

Page 2: ... 4 Maintenance and Repair 5 Chapter 2 General Introduction 6 2 1 Appearance 6 2 2 Functions 6 2 3 Hardware 6 2 4 Appearance Introduction 6 Chapter 3 Accessories 8 3 1 Desktop battery charger 1 8 3 2 Charger cable 1 8 3 3 Earphone 1 8 3 4 Batteries 2 9 Chapter 4 Product Definition 10 4 1 Interface Definition 10 Chapter 5 Before use 11 5 1 Charging 11 5 2 Buy the SIM Card 11 5 3 Insert the SIM card ...

Page 3: ...attery for 2 3 times for not less than 12 hours each time so as to ensure the battery in good condition Please charge the battery with the charger provided by our company All damages due to the use of any other charger are on the user s account Don t drop the batteries in fire for fear of burning or explosion of the batteries Don t put any stress on the batteries during battery installation or the...

Page 4: ...s and the charger are not waterproof don t use them in a highly wet place such as a bathroom or in the rain Only the maintenance personnel specially trained by our company are allowed to repair the product Any unauthorized disassembly or repair on this product might disable the warranty or lead to damage to this product 1 2 6 Network Service As the function realization of the product depends on th...

Page 5: ... of time 1 4 Maintenance and Repair Don t dismantle any part of the system for fear of malfunction If there is any problem please turn to the local agent or after service center Don t put the mainframe directly in the sun dampness dust or heat When it is used at the edge of normal temperature its normal operation will be affected but that does not mean any failure or error Just take it easy Avoid ...

Page 6: ... 2 3 Hardware Charging voltage 110 220V Working temperature 20 65 Humidity 5 95 Limited working temperature 30 C 40 C 80 C 85 C Storing temperature 45 C 90 C Start up time hot start 1 5s Warm start 34s Cold start 35s Autonomous Accurate positioning 3 0 m 2D RMS DGPS 2 5 m Speed Positioning 0 1m s DGPS 0 05m s Power consumption standby 48mA Depending on the system network state and the user s opera...

Page 7: ...er left blue button is the mode interface shifting key the upper right button is the emergency dial SOS key and the central right button and the lower right key are dial keys See Figure 2 Figure 2 Power on off Earphone Charger Mode SOS Phone 1 Phone 2 ...

Page 8: ...ShenZhen V Sun Electronics Co Ltd 8 Chapter 3 Accessories 3 1 Desktop battery charger 1 Figure 3 3 2 Charger cable 1 Figure 4 3 3 Earphone 1 Figure 5 ...

Page 9: ...ShenZhen V Sun Electronics Co Ltd 9 3 4 Batteries 2 Figure 6 ...

Page 10: ...nition The upper left Signal 1 on the latitude and longitude interface is GSM signal indication The upper left Signal 2 on the latitude and longitude interface is GPS signal indication Push the Shift key to shift between the analogue clock interface and the digital clock as shown below ...

Page 11: ...ging icon will keep flashing Remarks If the device is idle for a long time the batteries in it might be of lower power than the initial power Then it will take a few minutes to charge the batteries to resume the normal condition Low Cell When the battery power is almost used up during normal operation or when the device is turned on the terminal will give out the low cell alarm After a while the t...

Page 12: ... on the device and enter the main interface 6 2 2 Turn Off Hold on to Key 1 to turn off the device 6 2 3 Interface Shift Push Key 2 to shift 6 2 4 Emergency Alarm Push Key 4 for emergency alarm operation and the interface indication will be Then the watch will dial the three phone numbers preset in it in turn For more information about the setting method seethe appendix If the first phone number i...

Page 13: ...t When the phone is got through the watch will enter the call interface Remarks For more information about the setting of the emergency alarm call and the Call 2 and Call 3 commands please refer to the appendix 6 2 6 Calling and Auto answer If there is an incoming call on the terminal the interface will be Then push the SOS key to get through the call If the call is not got through manually it wil...

Page 14: ...ceives the SMS and confirms the user password correctly it switches to the SMS application mode After the success it will send the confirmation messages SET MODE OK CURRENT MODE SMS P2P to the sender 1 2 Set up the user password instruction Format 777 new password 4 figures old password 4 figures eg 77712340000 Explanation Confirm the user password correctly changes the new user password to the ol...

Page 15: ...st instruction Format 666 user password 4 figures eg 6660000 Explanation When v sun 680 tracker receives the instruction and confirms the user password correctly reads the GPS information No matter whether effective the information with the replying base station which is the set of the original software will be sent to the sender Data format Lat Latitude Direction Latitude Value Accuracy for 5 aft...

Page 16: ...ff Fix V ID 353686009002030 STATE SMS If in the cold start and GPS no position it will return to the void of information ERROR GPS GPRMC FRAME DATA BS 27971054 1 5 Send the positional information in fixed time instruction Format 4 xx user password 4 figures eg 4010000 Explanation x indicates one figure from 0 to 9 while xx 60 its unit is minute while xx 60 its numerical value is xx minus 60 and un...

Page 17: ... reset configuration reset After factory set or reset timing upload is stop 1 6 Telephone localization function Explanation One of 3 telephone numbers stored in advance calls in and hangs up after ringing 2 5 times then the v sun 680 will send the location information in form of 1 4 to this number the information state item automatically updates STATE CALL 1 7 Seeking help initiatively When press ...

Page 18: ...uctions and confirms the user password is correct it will send confirmation message time zone Eastern Western xx For example Set 8960000E08 instruction V680 screen time for GPS time plus 8 set 8960000W07 instruction V680 screen time for GPS time minus 7 Note V680 displayed on the screen the initial time GPS time ie Greenwich Mean Time 1 10 Point to Point inquiry Format 123 Description When the V68...

Page 19: ...e the user name Format 801 user password new user name eg 801 0000 username Explanation When v sun 680 tracker receives the instruction and confirms the user password correctly changes the user name to the new user name After the success it will send the confirmation messages to the sender The content is CHANGE USERNAME OK 2 3 Change the service password Format 802 user password new service passwo...

Page 20: ... content is SET GPRS APN OK if it is format 2 the content is SET GPRS ACCOUNT OK 2 5 Set up the TCP IP server and IP s address and port number Format 804 user password fixed IP address port eg 804 0000 222 125 12 32 80 Explanation When v sun 680 tracker receives the instruction and confirms the user password correctly updates the IP address and port number preserved in the module After the success...

Page 21: ...ing is second 5 seconds at least 65535 seconds at most The number of upload data each time at least is 10 at most is 80 When v sun 680 tracker receives the instruction and confirms the user password correctly sends the confirmation messages to the sender The content is SET GPS SAMPLING TIME AND QUANTITY OK At the same time as specified in the instructions to the sampling interval time continuous r...

Page 22: ...em automatically updates STATE SOS At the same time call the first user telephone number If it is unsuccessful closed or unable to connect or no response makes vibration and starts calling the second and the third in turn 2 10 Function of answering and ending calls active calls automatic answer end Note When one of the stored phone numbers of calls come in the user can take the initiative to press...

Page 23: ...two modes 777 new password old password Change user password in two modes 801 user password new user name Change the user name in GPRS mode 802 user password new service password old service password Change service password in GPRS mode 803 user password APN Set up access GPRS points in GPRS mode 804 user password fixed IP address port Set up TCP IP server s IP address and port number in GPRS mode...

Reviews: