Instruction
Instruction
Instruction
Instruction Manual
Manual
Manual
Manual V3.0
V3.0
V3.0
V3.0 for
for
for
for TLT-1C
TLT-1C
TLT-1C
TLT-1C GPS/GSM
GPS/GSM
GPS/GSM
GPS/GSM On-Vehicle
On-Vehicle
On-Vehicle
On-Vehicle Tracker
Tracker
Tracker
Tracker
22
22
22
22////40
40
40
40
returned from “request for single positioning” to the three prestored phone numbers. Information status is STATE:
SOS. At the same time, the first prestored phone number will be called. If it fails (the phone is turned off or cannot
be connected), the second and the third phone number will be called in sequence.
Note:
Note:
Note:
Note:
If calling status is off, message will be sent to prestored user instead of calling him.
1
1
1
14
4
4
4.... Power
Power
Power
Power off
off
off
off Alarm
Alarm
Alarm
Alarm
Instruction
Instruction
Instruction
Instruction to
to
to
to turn
turn
turn
turn on
on
on
on power
power
power
power cutoff
cutoff
cutoff
cutoff warning:
warning:
warning:
warning:
011+user password
For
For
For
For example:
example:
example:
example:
0110000
Instruction
Instruction
Instruction
Instruction to
to
to
to turn
turn
turn
turn off
off
off
off power
power
power
power cutoff
cutoff
cutoff
cutoff warning:
warning:
warning:
warning:
010+user password
For
For
For
For example:
example:
example:
example:
0100000
Description:
Description:
Description:
Description:
After receiving instruction 011, the device will return confirmation information:
DEFENCE
DEFENCE
DEFENCE
DEFENCE ON
ON
ON
ON
and enter defence status. Once external power supply is cut off unexpectedly, the device will send positioning
information of “request for single positioning” to the three prestored numbers. Information status is STATE: DEF.
At the same time, the first prestored phone number will be called. If it fails (the phone is turned off or cannot be
connected), the second and the third phone number will be called in sequence.
After receiving instruction 010, the device will return confirmation information:
DEFENCE
DEFENCE
DEFENCE
DEFENCE OFF
OFF
OFF
OFF
. Then
power cutoff warning function is cancelled and the device will stop monitoring unexpected cutoff of external
power supply.
Note:
Note:
Note:
Note:
1. Default power cutoff warning is off.
2. If calling status is off, message will be sent to prestored user instead of calling him.
1
1
1
15
5
5
5.... Fuel
Fuel
Fuel
Fuel cutoff
cutoff
cutoff
cutoff function
function
function
function
15.1.
Fuel
Fuel
Fuel
Fuel cutoff
cutoff
cutoff
cutoff and
and
and
and power
power
power
power failure
failure
failure
failure
1
1
1
15
5
5
5.1.1
.1.1
.1.1
.1.1 Fuel
Fuel
Fuel
Fuel cutoff/power
cutoff/power
cutoff/power
cutoff/power failure
failure
failure
failure message
message
message
message instruction:
instruction:
instruction:
instruction:
900+user password
1
1
1
15
5
5
5.1.2
.1.2
.1.2
.1.2 Fuel
Fuel
Fuel
Fuel cutoff/power
cutoff/power
cutoff/power
cutoff/power failure
failure
failure
failure message
message
message
message confirmation
confirmation
confirmation
confirmation instruction:
instruction:
instruction:
instruction:
901+user password
Description:
Description:
Description:
Description:
As fuel cutoff/power failure operation is dangerous to some extent, one more confirmation
operation is necessary.
After receiving instruction 900, TLT-1C will return confirmation message “Confirm Power OFF?” and wait
for instruction 901. If it receives confirmation instruction (901) sent by the user within 10 minutes, TLT-1C fuel
channel power supply will be cut off. After completion, it will return confirmation message “POWER OFF OK”.
15.1.3
15.1.3
15.1.3
15.1.3
Fuel
Fuel
Fuel
Fuel cutoff/power
cutoff/power
cutoff/power
cutoff/power failure
failure
failure
failure single
single
single
single instruction
instruction
instruction
instruction format:
format:
format:
format: 940+user
940+user
940+user
940+user password
password
password
password
Description:
Description:
Description:
Description:
940=900+901. After receiving instruction from prestored number, TLT-1C will immediately
perform fuel cutoff/power failure.