6.1.2.4
Working Interval
–
Step 4
In this page, opening and closing hours of the store, shopping mall or the counting area shall
be set. Setting Monday will set all the week days. But also, other days can be set individually.
For siesta or pray hours or for any other purposes, additional intervals in a day can be set
from + signs.
Figure 39 Working Interval Settings
6.1.2.5
Wi
–
Fi Processing
–
Step 5
In this page, parameters for Wi
–
Fi and BLE signal detection are set. These parameters are:
Max Signal Value:
Signals that are weaker than this signal value will be discarded. Be careful
about the minus sign!
Max Store Signal Value:
Signals that are stronger than this signal value are marked as inside
the store. For BLE projects Max Signal Value and Max Store Signal Value shall be set to -100.
Query Period:
Number of minutes to query the BLE Signals from embedded chip.
Time Difference:
Number of minutes to match the signals from master and slave device.
Time Signal Difference:
Number of minutes to continue to mark target as inside.