Working height: max 2000m
Display: 2000counts LCD display
Maximum display value: 1999 number
Polarity indication: automatic indication, '-' indicates negative polarity.
Overrange display: '0L' or '-0L'.
Sampling time: about 3 times / sec
Unit display: with function, power unit display.
automatic shutdown time: no letter when about 15 minutes
Power supply: DC power supply 9V
Battery Type: 6F22 9V Battery Battery
Battery undervoltage indication: LCD display
symbol .
Temperature coefficient: less than 0.1
×
accuracy /
℃
Operating temperature: 18
℃
~ 28
℃
Storage temperature: -10
℃
~ 50
℃
Size: 140 (L) × 68 (W) × 49 (H) mm
Weight: about 226g (including battery)
3.2
Technical indicators
Ambient temperature: 23
±
5
℃
Relative humidity: <75%
3.2.1
True rms zero input
3.2.1.1 The measurement of sine wave signal, the use of true RMS measurement method than
the traditional average response method error is small.
3.2.1.2 True RMS The instrument can accurately measure the sine wave signal, but if it
is on the AC function, the instrument may display 1 to 50 if the measured signal is not
input (shorted at the AC voltage range and the input terminal) Word between a reading.
These deviations are normal. Within the specified measuring range, they do not affect
the accuracy of the multimeter to measure alternating current.
3.2.1.3 True RMS requires that the input signal reach a certain level for measurement.
Therefore, the AC voltage and current range is specified between 2% and 100% of full
scale.