a.
Remove everything from platter
b.
Press
TARE
again and
NET
indicator should turn off and
ZERO
indicator
should appear as scale has returned to zero weight condition
NOTE:
It is regulated by OIML R76 that in dual range application, tare value will be
cancelled automatically when returning from W2 to W1.
5.4
HOW TO CHANGE UNIT PRICE MODE
When purchasing an item with a higher unit price, the scale supports to
calculate unit price per kg or unit price per 100g, and be able to put them on
the same receipt. Before enable this switching, make sure the platter is empty
and zero indicator is on.
a.
Press and hold the
MODE
key
b.
Use
M+/MC
key and refer to the weigh unit indicator to select between
/kg
or
/100g
c.
Press
ZERO
to confirm and return to normal weighing mode
d.
If no decision is made or confirm executed, scale will return to normal after
10 seconds
5.5
HOW TO FIX A UNIT PRICE
It is restricted by the legislation that unit price entered must be automatically
cancelled when loads are removed. So if the same unit price will be used for
subsequent transactions, user can activate this function without enter
repeatedly.
a.
Use numeric keypad to enter the unit price
b.
Press
FIX
and
Fixed Unit Price
indicator is on
c.
The same unit price will remain on unless it is cancelled manually
d.
To cancel, press
FIX
again and
Fixed Unit Price
indicator will be off. The
price entered will be cancelled automatically when loads are removed from
platter.
5.6
HOW TO CALCULATE A NON-WEIGHED ITEM
This scale not only calculates weighable item but also no-weighed item, and
able to calculate the total price.
a.
Use numeric keypad to enter the unit price
b.
Press
X
and
“
n._000
”
will appear in the
WEIGHT
window for quantity to be
entered
Summary of Contents for VGP-15