2 Operation
II Uwatec
®
Smart dive computers
II
2.2 Switching on the display
• automatically, on submerging in water or when adaptation to atmospheric
pressure is necessary.
• manually by manipulating contacts on housing (B-E).
•
COM
on opening the tank valve (if connected) (Tank pressure
≥
8 bar / 116 psi).
•
When the Smart is in state of rest; no information is dis-
played but the atmospheric pressure is continuously moni-
tored. If a higher altitude is detected, it switches on for 3
minutes automatically. See also page 21.
•
The Smart switches on by bridging the contacts B and E. To
check the display, all signs light up for 5 seconds.
Afterwards the display shows the selected O
2
mix, the tem-
perature and in certain circumstances an altitude section
(see page 21). The Smart Com displays the tank pressure
also.
If there is a remaining saturation due to the last dive or
change of altitude, the Smart also displays the remaining
desaturation time, the Oxigen toxicity and the "No fly time"
(see page 20).
2.3 Checking the battery capacity
After switching on the Smart you can check the battery capacity with the
contact E. The remaining capacity is displayed during 3 seconds as a percenta-
ge. If the value reaches 0%, the battery warning gets activated (see page 13)
and the battery has to be replaced by an authorised Scubapro-Uwatec dealer.
A battery capacity of 2 to 5 % is definitely enough energy for the dives of usual
dive vacations (20 to 50 dives).
DIVE TIME
DEPTH
DECO INFO
MAX.DEPTH
DIVE TIME
DEPTH
DECO INFO
MAX.DEPTH
%
C
DIVE TIME
DEPTH
DECO INFO
MAX.DEPTH
CNS O
2
%
h
DESAT
h
%
%
C
NO
No fly time
Oxygen Toxicity
Desaturation time
O
2
Mix
Temperature
DIVE TIME
DEPTH
DECO INFO
MAX.DEPTH
NO
NO
CNS O
2
%
h
LOG
DESAT
ft
h
m
DECO STOP
NO STOP
LEVELSTOP
S
L
O
W
%
SPEED
%
C
F
Do not fly
symbol
Battery capacity
DIVE TIME
%
2.4 Selection and Activation of User Functions
With the co and – you can select the Dive Planner,
the Logbook and the functions to enter the O
2
% Mix and
the Microbubble-Level.
After the selection of the desired function you can activate and deactivate it
with the contact E.
Details to the user functions are to be found on the pages mentioned above.
Input Microbubble-Level (page 24)
Input O
2
Mix (page 14)
Logbook (page 29)
Dive planner (page 27)