6.  INSTALLATION OF THE PRODUCT

Perform the following steps for the installation of the Product.

Outside every room where Far UV-C light is used, there must be information signs in clear 

line of sight. 

Installation must be done according to the local regulations by a qualified installer.

6.1. Choose the appropriate location

Choosing the appropriate location is important for the proper functioning and safe use of 

the Product. 

A DIALux simulation can help choosing the right position for optimal disinfection.

Install the Product in a protected area where the temperature does not fall below -10° C 

(14° F) and the humidity remains within the Product's specifications. The Product functions 

ideally in a temperature range from -10° to +50° C (14° to 122° F). 

Select a Product mounting location that is close to surface/area that you want to disinfect.

6.2. Unboxing and inspection

Read and save all notices, warnings, and safety instructions received with the Product. 

Open the box and carefully take the unit out of the box. Take the unit out of the plastic 

bag. Do not remove the protection label on the front of the Product. The protection label is 

intended to avoid unforeseen UV radiation. Make a visual inspection of the unit. 

Do not power on the unit until installed by a qualified installer!

CAUTION: 

Do not touch the glass of the lamp without gloves. 

Doing so may result in damage to the lamp. Oil from fingerprints will 

permanently etch the glass of the lamp and weaken the structure. 

Summary of Contents for UV222

Page 1: ...Filtered Far UV C Technical Installation Manual Industrial...

Page 2: ...UV LIGHT DO NOT USE THE PRODUCT BEFORE CAREFULLY READING THIS MANUAL ALWAYS KEEP THIS MANUAL WITH THE PRODUCT AND CONSULT IT REGULARLY ATTENTION Lumi re UV mise par cet appareil vitez de regarder dire...

Page 3: ...u suspect that the Product is damaged or detect a potential or actual danger when using the Product immediately discontinue use of the Product and contact your supplier of the Product Contents 1 USING...

Page 4: ...as oxygen hydrogen or chemicals near a lamp module Failure to obey may result in fire or explosion Do not turn on any Product with a broken front glass If the front glass is broken disconnect Product...

Page 5: ...acting on behalf of another person your employer that person must instruct you in accordance with the Manual and ensure that all instructions set out herein are complied with Do not use the Product if...

Page 6: ...ility are void if any modifica tions are done to the Product 4 GENERAL CHARACTERISTICS AND TECHNICAL SPECIFICATIONS UV222 Industrial has an IP66 rating and is designed to emit Far UV C radiation with...

Page 7: ...7 5 CONSTRUCTION 100 mm 3 9 in 110 mm 4 3 in R 3 5 mm 0 1 in 53 mm 2 1 in 60 mm 2 4 in 113 mm 4 4 in 300 mm 11 8 in 142 mm 5 6 in 168 mm 6 6 in...

Page 8: ...umidity remains within the Product s specifications The Product functions ideally in a temperature range from 10 to 50 C 14 to 122 F Select a Product mounting location that is close to surface area th...

Page 9: ...surface must be strong enough to hold 4 times the weight of the unit 100 mm 3 9 in 110 mm 4 3 in R 3 5 mm 0 1 in 53 mm 2 1 in 60 mm 2 4 in 113 mm 4 4 in 300 mm 11 8 in 142 mm 5 6 in 168 mm 6 6 in Tak...

Page 10: ...lead Standard wiring Phase Hot brown black Neutral Cold blue white Earth green yellow green How to wire the Product 1 Remove all screws and take off the back plate A 2 Unscrew 2x ph1 cable blockage B...

Page 11: ...nning of this installation 6 6 Setting up the Product The installer will need a Microsoft Windows computer with the UV Medico application installed Contact your distributor to get access to the latest...

Page 12: ...stallation Manual 12 1 If the Product was already installed you can recover its settings by pressing Get All settings will then be shown in the application A 2 Check if firmware version is the latest...

Page 13: ...ty cycle of the room where the Product is installed On time Time from which the room will be occupied by people E Off time Time from which the room will not be occupied F C Select the correct firmware...

Page 14: ...e and post cleaning cycle if desired B The unit will then light up before and after the duty cycle 7 Change the intensity of the LED signal to the desired output C 8 Select mode D NOTE The current mod...

Page 15: ...0 Press Set to upload the settings into the Product F F E Once this information is saved and programmed into the unit it is ready to test start up The unit will calculate the radiation automatically t...

Page 16: ...ence on the risks of exposure the installer needs to be contacted so the Product is repro grammed 11 Testing the Product Right click on the photo of the Product A and a pop up of the test mode will sh...

Page 17: ...continuous Out of cycle Flashing red Object too close Flashing magenta Pre disinfection after disinfection per seen movement Red blue green loop Recommended change of Far UV C light source If the LED...

Page 18: ...t Does not hold settings Replace battery If the failure is unsolved or recurring please return the unit to an official UV Medico dealer service centre for repair or replacement see point 10 REPAIRS 8...

Page 19: ...drawings The information given in this manual has been collected for the general convenience of our customers It has been based on general data pertaining to construction material properties and worki...

Page 20: ...UV Medico A S S ren Frichs Vej 40E 8230 byh j Denmark 45 20 90 71 30 info uvmedico com www uvmedico com Version 06 2022...

Reviews: