8
. Default settings.
IP address:
0.0.0.3, reserved for setting by ”arp-ping method” as described in section 10..
Port, http:
80
Authorization:
Basic
Name on the button:
IP-SwitchPlug
Turn on delay:
0s
Reset delay:
10s
Username/Password.
admin:
root/root_pwd
Changes this to prevent other to control it..
user:
1 / 1
Acessrights
unauthorized:
Read and write.
To restore defaults.
The settings can be restored to factory defaults.
This is done by pushing a small button located behind a
small hole just left of the RJ45 connector.
A thin item musts to be used, for example a paper clip.
a) Restore
only the
IP-address (0 0.0.0.3):
Switch off the power to the box.
Push and keep in the button.
Switch on the power to the box..
Release the button after a few seconds.
b) Restore
all settings
:
Do as above, a), two times after each other.
.
9. Technical specifications.
Mains connection
.
Mains voltage in:
230V
Max current:
16A
Power consumption:
approx 2W
Signal connection.
Ethernet 100/10M TP
Straight cable for connection to switch.
Crossed cable for direct connrction to PC
Green LED:
Lit when connected to network
Temporary unlit at communicatio (100ms)
Yellow LED:
Lit at full duplex.
Dimensions
:
Width:
65mm
Length:
120mm
Height:
55mm exclusive contact
Weight:
380g