background image

UTL260

INSTRUCTION MANUAL

Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com 

Summary of Contents for UTL260

Page 1: ...UTL260 INSTRUCTION MANUAL Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 TestEquipmentDepot com ...

Page 2: ...fully In this manual the word WARNING is used to indicate conditions or actions that may pose physical hazards to the user The word CAUTION is used to indicate conditions or actions that may damage this instrument WARNING Exceeding the specified limits of this meter is dangerous and can expose the user to serious or possibly fatal injury DO NOT attempt to measure any voltage that exceeds 600 volts...

Page 3: ...7 DC input indication 8 AC input indication 9 Polarityindication Operating Instructions If the current under measurement is higher than the selected value for a long period overheating may take place compromising the safety and operation of inner circuits WARNING DO NOT measure currents on high voltage conductors 600V to avoid risk of discharge and or incorrect readings AC Current Measurement WARN...

Page 4: ...00Vrms Do not attempt to take any voltage measurement that exceeds 600Vrms to avoid electrical shock hazard and or damage to the instrument 1 Set the rotary switch to the 600V range 2 Connect the black and red test leads to the COM and VΩ terminals respectively 3 Connect the test leads to the circuit being measured and read the displayed value Fig 3 Resistance Measurement WARNING Before taking any...

Page 5: ...bility of the structural components Battery Replacement Always use a fresh replacement battery of the specified size and type Immediately remove the old or weak battery from the meter and dis pose of it in accordance with your local disposal regulations Old or defective batteries can leak chemicals that corrode electronic circuits WARNING To avoid electric shock be sure to turn off the meter s pow...

Page 6: ...digits at 64 to 82 F 18 to 28 C with relative humidity to 80 AC Current Frequency response 50 60Hz DC Voltage Input impedance 10MΩ Maximum input voltage 600V DC or 600V AC rms AC Voltage Input impedance 10MΩ Frequency response 40 400Hz Maximum input voltage 600V DC or 600V AC rms Resistance Open circuit voltage less than 700mV Overload protection 250V DC or 250V AC rms UTL260 MAN P 5 Range Resolut...

Page 7: ... of merchantability and fitness for a particular purpose are limited to the express warranty UEi shall not be liable for loss of use of the instrument or other incidental or consequential damages expenses or economic loss or for any claim or claims for such damage expenses or economic loss A purchase receipt or other proof of original purchase date will be required before warrantyrepairs will be r...

Reviews: