--
598-1291-02
Controlling Non-Motion Sensing Fixtures
❒
When wiring to additional standard fixture
only:
Strip the motion sensor's
red
wire and
connect to the standard fixture's
black
wire.
Connect all white wires together. Total fixture
ratings must not exceed 1000 Watts (8.3 A).
NOTE:
All wiring between fixtures should be run
in accordance with the National Electrical
Code (Canadian Electrical Code in Canada)
through conduit or another acceptable means.
Contact a qualified electrician if there is any
question as to the suitability of the system.
❒
This fixture is provided with a sensor rated
for 1000 Watts. Since the fixture is only rated
500 Watts, 500 Watts of additional load may
be controlled by this sensor.
❒
When determining what a fixture is rated for,
do not simply look at the rating on the lamp in
the fixture. Look at the marking which speci-
fies the maximum lamp wattage for which the
fixture is suitable.
❒
Once you have selected the fixtures to be con-
nected and determined their maximum ratings,
add these ratings up. For instance, if you have 3
fixtures rated 100 Watts, 150 Watts, and 75 Watts
respectively, you have a total load of 325 Watts.
Wiring to a Motion Light & Standard Fixture
Standard
Fixture
RED from Security Light to
BLACK from Fixture
BLACK from Switch to
BLACK from Security Light
WHITE from Line
to
WHITE from
Security Light
WHITE from Line to
WHITE from Fixture