background image

12

WARRANTY

READ AND KEEP IN YOUR POSSESSION!

TO PREVENT UNNECESSARY EXPENSE AND INCONVENIENCE, CALL THE TECHNICAL 

ASSISTANCE NUMBER BELOW BEFORE REMOVING TANK FROM YOUR SYSTEM!
HOW THE OWNER CAN MAKE A CLAIM: TAKE THIS REGISTRATION, YOUR SALES RECEIPT AND THE TANK TO THE LOWES STORE 

SERVING YOUR AREA. THE STORE REPRESENTATIVE WILL VERIFY WARRANTY REGISTRATION WITH THE MANUFACTURER.

REGISTRATION IS A CONDITION OF WARRANTY

 - FILL OUT COMPLETELY AND MAIL THE WARRANTY REGISTRATION 

CARD INCLUDED IN THIS MANUAL WITHIN 60 DAYS OF PURCHASE OF THE WATER TANK. IF YOU MISPLACE THE 

CARD, OR IF THE REGISTRATION CARD HAS NOT BEEN INCLUDED IN THIS MANUAL, MAKE A PHOTOCOPY OF THIS 

PAGE AND MAIL TO ADDRESS BELOW, OR CALL THE SERVICE DEPARTMENT AT THE NUMBER LISTED ABOVE.

LIFETIME LIMITED WARRANTY - RESIDENTIAL TYPE PRECHARGED PUMP TANK FOR INSTALLATION IN FAMILY 

RESIDENTIAL UNIT

A.  WHO IS COVERED: “The Company” (hereafter referred to as the “manufacturer”) warrants only to the original consumer purchaser (hereafter 

referred to as the “owner”) of the pump tank so long as he or she continuously occupies the home or dwelling in which this pump tank is initially 

installed for the period specified below. Return of the warranty registration card is a condition that must be satisfied before you have coverage. The 

warranty is restricted to the pump tank used by a single-family residential unit for non-commercial purposes in the United States of America. 

B.  WHEN IS IT COVERED: The pump tank is warranted against failure only when installed, operated and maintained in accordance with the 

printed instructions accompanying the pump tank.

C.  WHAT THE MANUFACTURER WILL DO:

  1.  THE TANK  -  If  the  original  tank  fails  after  the  original  installation,  within  the  lifetime  of  the  original  owner  (as  spelled  out  in A 

  above) “manufacturer” or its representative will furnish a new pump tank of manufacturer’s prevailing comparable model (see 3). If 

   governmental  regulations  or  industry-wide  standards  prohibit  manufacturer  or  its  representative  from  furnishing  a  comparable 

   model  replacement  pump  tank  under  this  warranty,  the  owner  will  be  furnished  with  a  new  pump  tank  of  comparable  storage 

   capacity  as  permitted  by  such  governmental  regulations  or  industry-wide  standards;  however,  the  owner  will  be  charged 

   for  the  additional  value  of  the  item(s)  which  manufacturer  has  incorporated  in  the  replacement  pump  tank  which  does  comply 

   with such governmental regulations or industry-wide standards.

 

2. RETURN OF THE DEFECTIVE PUMP TANK: manufacturer reserves the right to examine the alleged defect in the pump tank 

  or its component part(s), and it will be the owner’s obligation to return the pump tank and or component part(s) to the manufacturer 

  or its representative.

    (a) When returning a pump tank it must include all component part(s) and the warranty label.

    (b) When returning component part(s), they must be tagged or labeled with the pump tank’s model number and serial number 

    and date of installation.

    (c) Take  this  registration,  your  sales  receipt  and  the  tank  to  the  Lowes  store  serving  your  area. The  store  representative  will 

    verify warranty registration with the manufacturer.

D.  WHAT  THIS  WARRANTY  DOES  NOT  COVER: 

  1. THIS LIMITED WARRANTY SHALL BE THE EXCLUSIVE WARRANTY MADE BY THE MANUFACTURER AND IS MADE IN LIEU 

 

  OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, WHETHER WRITTEN OR ORAL, INCLUDING THE IMPLIED WARRANTY 

 

  OF  MERCHANTABILITY  AND  IMPLIED  WARRANTY  OF  FITNESS  FOR  A  PARTICULAR  PURPOSE.

  2. Manufacturer shall not be liable for any incidental, consequential, special or contingent damages or expenses, arising directly or

 

   indirectly, from any defect in the pump tank or its components or from any use of the pump tank.

  3.  Manufacturer  shall  not  be  liable  for  any  water  damage  arising,  directly  or  indirectly,  from  any  defect  in  the  pump  tank  or  its 

   component part(s). Further, manufacturer shall not be liable under this warranty if, including but not limited to;

    (a) the pump tank or any of its component part(s) have been subject to misuse, alteration, neglect or accident; or

    (b) the pump tank has not been installed in accordance with the applicable local building and/or plumbing code(s) and/or regulations; or

    (c) the pump tank is not installed in accordance with the printed manufacturer’s instructions; or

    (d) the pump tank is not continuously supplied with potable water; or

    (e) the pump tank does not have installed in the system in which it is used a suitable pressure relief valve, or:

    (f)  the pump tank is used in a commercial or industrial application.

  4.  The owner, and not the manufacturer, or his representatives, shall be liable for and shall pay for all field charges for labor or other expenses

 

  incurred in the removal, repair or replacement of the pump tank or any component(s) claimed to be defective. Such charges may include, but are 

  not necessarily limited to:

    (a) all freight, shipping and delivery costs of forwarding a new pump tank or replacement part to the owner.

    (b) all costs necessary or incidental in removing the defective pump tank or component part(s) and installing a new pump or component part(s).

    (c) any  material  required  to  complete,  and/or  permits  required  for,  installation  of  a  new  pump  tank  or  replacement  part(s),  and

 

   (d) all costs necessary or incidental in returning defective pump tank or component part(s) to a location of nearest dealer of pump tank.

E.  HOW STATE LAW MAY RELATE TO THIS WARRANTY: YOUR STATE MAY PROHIBIT OR PLACE LIMITATIONS ON THE MANUFACTURER’S 

EXCLUSION OF CERTAIN WARRANTIES AND/OR MAY PROHIBIT OR LIMIT THE MANUFACTURER’S EXCLUSION OF CERTAIN 

DAMAGES SO THE ABOVE LIMITATIONS OR EXCLUSIONS MAY NOT APPLY TO YOU.

F. 

This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

  *NOTE A PUMP TANK SHOULD BE INSTALLED IN SUCH A MANNER THAT IF THE TANK OR ANY CONNECTION THERETO SHOULD 

LEAK, THE RESULTING FLOW OF WATER WILL NOT CAUSE DAMAGE TO THE AREA IN WHICH IT IS INSTALLED. A PUMP TANK 

SYSTEMS PRESSURE RELIEF VALVE MUST BE PIPED TO THE NEAREST DRAIN IN ORDER TO AVOID DAMAGE IN THE EVENT 

THE VALVE IS ACTIVATED. FOR DETAILED INSTRUCTIONS REFER TO YOUR LOCAL PLUMBING AND/OR BUILDING CODE(S).

For Technical Assistance or Service Information you should write to 

A. O. Smith, 500 Tennessee Waltz Parkway, Ashland City, TN 37015. 

Summary of Contents for 119032

Page 1: ...ing parts Before returning to your retailer call our Technical Assistance Team at 1 800 549 6233 7 00 a m 7 00 p m CST Monday Friday ITEM 119032 PUMP TANK MODEL LLT25 Fran ais p 13 Espa ol p 25 PRINTE...

Page 2: ...dous situation which if not avoided could result in death or injury CAUTION indicates a potentially hazardous situation which if not avoided could result in minor or moderate injury All safety message...

Page 3: ...er installation be sure the pressure switch is set low enough to shut the pump off If all valves are closed and the pressure switch setting is too high the pump will run continuously without water flo...

Page 4: ...damage The Discharge Pipe Must not be smaller in size than the outlet pipe size of the valve or have any reducing couplings or other restrictions Must not be plugged or blocked Must be installed so as...

Page 5: ...1 in NPTF Weight in Pounds 39 5 PIPING PVC pipe is shown in the illustrations but copper or galvanized steel pipe may be used if desired All piping must be clean and free of all foreign matter ALL JOI...

Page 6: ...e tank to service line One male 1 in PVC adapter One 1 in X 11 in tank cross Two 3 8 in plugs One 1 2 in boiler drain One 1 2 in street tee REMINDER All joints and connections must be airtight A singl...

Page 7: ...of street tee TANK CROSS 3 4 in PRESSURE RELIEF VALVE 3 4 in BOILER DRAIN Figure 1 Step 1 STEP 2 Thread 1 in male PVC adapter into the inlet side of tank cross 1 in MALE PVC ADAPTER Figure 2 Step 2 S...

Page 8: ...ing the Tank Pressure The tank pressure must be set 2 PSI lower than the pump cut on pressure Check tank pressure with a standard air gauge valve at the top of the tank as needed Other Tank Installati...

Page 9: ...9 NOTES...

Page 10: ...10 NOTES...

Page 11: ...11 NOTES...

Page 12: ...tore serving your area The store representative will verify warranty registration with the manufacturer D WHAT THIS WARRANTY DOES NOT COVER 1 THIS LIMITED WARRANTY SHALL BE THE EXCLUSIVE WARRANTY MADE...

Page 13: ...pporter le produit votre d taillant appelez notre quipe d assistance technique au 1 800 549 6233 entre 7 h et 19 h HNC du lundi au vendredi ARTICLE No 119032 R SERVOIR POUR POMPE MOD LE No LLT25 Engli...

Page 14: ...me pour viter les risques de blessures ou de mort DANGER indique un risque imminent qui entra nera la mort ou des blessures s il n est pas vit AVERTISSEMENT indique un risque potentiel pouvant entra n...

Page 15: ...surez vous que le pressostat est r gl un niveau suffisamment bas pour arr ter la pompe Si toutes les valves sont ferm es et que le pressostat est r gl un niveau trop lev la pompe fonctionnera continue...

Page 16: ...e le tuyau de sortie de la soupape ni tre muni de raccords de r duction ou de toute autre restriction Ne doit pas tre bouch ni bloqu Doit tre install de fa on que l on puisse effectuer le drainage com...

Page 17: ...7 92 TUYAUX Les illustrations montrent des tuyaux en PVC mais des tuyaux en cuivre ou en acier galvanis peuvent galement tre utilis s Toute la tuyauterie doit tre propre et exempte de toute substance...

Page 18: ...adaptateur m le en PVC de 2 54 cm Un croisillon de r servoir de 2 54 cm x 27 94 cm Deux bouchons de 0 95 cm Un drain de chaudi re de 1 27 cm Un t m le femelle de 1 27 cm RAPPEL Tous les joints et rac...

Page 19: ...OIR SOUPAPE DE D CHARGE DE 1 9 mm DRAIN DE CHAUDI RE de 1 9 mm Figure 1 tape 1 TAPE 2 Ins rez l adaptateur m le en PVC de 2 54 cm dans le c t du croisillon du r servoir servant l entr e d eau ADAPTATE...

Page 20: ...it tre r gl e 2 lb po2 plus bas que la pression de point de coupure de la pompe V rifiez la pression du r servoir au besoin l aide d un manom tre standard plac sur le dessus du r servoir Autres instal...

Page 21: ...21 NOTES...

Page 22: ...22 NOTES...

Page 23: ...23 NOTES...

Page 24: ...egistrement de la garantie aupr s du fabricant D CE QUI N EST PAS COUVERT PAR CETTE GARANTIE 1 CETTE GARANTIE LIMIT E CONSTITUE LA SEULE GARANTIE OFFERTE PAR LE FABRICANT ET PR VAUT SUR TOUTE AUTRE GA...

Page 25: ...ame a nuestro equipo de asistencia t cnica al 1 800 549 6233 de lunes a viernes de 7 a m a 7 p m hora central est ndar ART CULO 119032 TANQUE DE BOMBA MODELO LLT25 English p 1 Fran ais p 13 IMPRESO EN...

Page 26: ...onar la muerte o lesiones PRECAUCI N indica una situaci n de posible peligro que de no evitarse puede ocasionar lesiones menores o moderadas Todos los mensajes de seguridad generalmente indican el tip...

Page 27: ...le en un lugar lo suficientemente bajo para apagar la bomba Si todas las v lvulas est n cerradas y el ajuste del interruptor de presi n tiene un valor muy alto la bomba funcionar continuamente sin flu...

Page 28: ...ubo de salida o tener acopladores reductores u otras restricciones No debe estar atascado o bloqueado Debe estar instalado de manera que permita el desag e completo de la v lvula de descarga de presi...

Page 29: ...A En las ilustraciones se muestran tubos de PVC pero pueden usarse tubos de cobre o de acero galvanizado si se desea Todas las tuber as deben estar limpias y libres de sustancias extra as TODAS LAS U...

Page 30: ...nes de 3 8 pulgada Un desag e de caldera de 1 2 pulgada Un conector en T de 1 2 pulgada RECORDATORIO todas las uniones y conexiones deben ser herm ticas Las filtraciones de un solo orificio peque o im...

Page 31: ...VULA DE DESCARGA DE PRESI N DE 3 4 DE PULGADA DESAG E DE CALDERA DE 3 4 DE PULGADA Figura 1 Paso 1 PASO 2 EnrosqueeladaptadormachodePVCde1pulgada en el lado de entrada del cruce del tanque ADAPTADOR M...

Page 32: ...UE VERTICAL Ajuste de la presi n del tanque La presi n del tanque debe ajustarse a 2 PSI menos que la presi n reducida Revise la presi n del tanque con una v lvula de calibre de aire en la parte super...

Page 33: ...33 NOTAS...

Page 34: ...34 NOTAS...

Page 35: ...35 NOTAS...

Page 36: ...ienda Lowes que opere en su rea El representante de la tienda verificar el registro de la garant a con el fabricante D LO QUE ESTA GARANT A NO CUBRE 1 ESTA GARANT A LIMITADA SER LA GARANT A EXCLUSIVA...

Reviews: