![UTIFORM Delta-Mini Instructions Manual Download Page 24](http://html.mh-extra.com/html/utiform/delta-mini/delta-mini_instructions-manual_1065260024.webp)
Mini Pump
23
9
Faults and corrective actions
Faults in the Mini pump can be eliminated very simply by performing a small number of
operations. When eliminating these faults, it is essential that you comply with the following
rules:
1. Before opening the control panel door, disconnect the machine from the mains!
2. Whenever working with moving parts of the machine, turn off the main switch or
remove the plug from the power supply socket!
3. Work on the electronic control devices and valves must only be performed by
specialised service personnel!
FAULT CAUSE
ELIMINATION
Machine does not
start
No power supply
Switchgear
Insufficient water pressure
Check electricity cable and electric connectors.
Check 16 A. delayed-action fuses in the main
circuit board at the work site.
Turn the black buttons on the control panel.
Increase the water supply to at least 3 bars and if
necessary use a pump to increase pressure.
The machine works
for short periods and
then stops.
The hose is blocked.
Insufficient water supply.
Check the water supply hose (diameter 3/4”) with
respect to the narrow transversal sections (e.g.
creases)
Use other water supply points with larger
transversal supply sections or use a water barrel
with pump.
The main motor stops
after the machine is
started.
The thermal protection of
the variator has been
activated due to high
consumption by the motor
Pump blocked by material
remains.
Pump blocked due to use
when dry.
Check the input current voltage. Recommended
voltage: 230 V.
Disassemble the maintenance perpetual screw
sleeve, dismantle, clean and reassemble.
Control the water input in the mixing tube and if
necessary loosen the perpetual screw using the
rotating tool and start the pump with sufficient
water.
The machine stops
during operation or
cannot be started
from the spraying
lance after a pause in
work.
Power cut
No water
Blocked air diffuser
Re-establish the electricity supply and start the
machine using the pump control.
Re-establish the water supply and start the machine
using the pump control.
Stop the machine using the pump control and clean
the air diffuser thoroughly using the
piquera
or
check for any obstruction in the air hose.
The water level rises
in the mixing tube
when the machine is
Incorrect rotation direction
Too much water.
Change the position of the manual phase invertor
on the electronic control panel.
Summary of Contents for Delta-Mini
Page 15: ...Mini Pump 14 6 1 Commissioning of the DF DV51 variator ...
Page 16: ...Mini Pump 15 ...
Page 17: ...Mini Pump 16 ...
Page 18: ...Mini Pump 17 ...
Page 19: ...Mini Pump 18 Fault correction ...
Page 20: ...Mini Pump 19 ...
Page 49: ......
Page 50: ......
Page 51: ......
Page 52: ......
Page 53: ......
Page 54: ......
Page 55: ......
Page 56: ......
Page 57: ......
Page 58: ......
Page 59: ......
Page 60: ......