11473012 Rev B
10
© 2007, UTC RETAIL
Flashing Text Stop
<GS>
29 DEC
1D HEX
After receipt of this command, the characters following will not flash.
Clear to End of Line Feature
<CAN>
24 DEC
18 HEX
This command will clear out the display from the current write-in position to the end of the current line. The current
write-in position will not change.
Clear to End of Display Feature
<EM>
25 DEC
19 HEX
This command will clear out the display from the current write-in position to the end of the second line. The current
write-in position will not change.
Home and Clear Display Feature
<RS>
30 DEC
1E HEX
This command will clear the display and move the write-in position to the first position of the first row.
Display Character Codes
For a full listing of the display character codes used by the UT1800 Customer Display, refer to the ASCII Character
Set in the table on the next page.