UTC RETAIL PD1200 Installation Manual Download Page 2

11393107 Rev E 

 

PD1200 Pole Display Installation Guide 

11393107E 

 

UTC RETAIL 

Install the Pole Display 

1.  Open the pole display box and remove 

the pole display. 

2.  Remove all packing materials. 
3.  If the pole display is being used with an 

UTC RETAIL POS system that has a 
hat bracket already installed: 
 

Insert the pole display into the hat 
bracket. 

 

- or -  

If the display pole is free standing: 
a.  Install the hat bracket on the base 

plate. 

b.  Install the base plate and hat 

bracket in the proper location. 

c.  Insert the pole assembly into the 

hat bracket. 

4.  Route the pole display data cable to the 

POS logic unit port. 

5.  Plug the pole display data cable into 

appropriate logic unit port  USB or Com 
Port 

 

Figure 1:  POS System 

Figure 2:  Free Standing 

RS232 Pole Display Factory Settings Baud -rate = 9600, Word length = 8, Stop bits = 2, Parity = 
None.  Refer to the PD1200 Pole Display Programming guide to change baud rates or parity. 

Power-Up 

Plug the barrel type connectors at the ends of the black power wire and the wall transformer wire 
together.   Place the wall transformer into a 120-volt AC power source.  For RS232 units ,the display 
unit will momentarily display UTC RETAIL ROM version. 

For USB controlled Customer Displays the Software Driver must be installed in order to operate the 
unit.  Go to 

http://www.utcretail.com/

 to obtain the correct driver for your needs. 

You have completed the installation of Ultimate Technology’s PD1200 Pole Display. If you experience problems with any of the 
components of the PD1200 Pole Display, see the “Troubleshooting Procedures” section below. 

Troubleshooting Procedures 

The following table presents symptoms and solutions for problems potentially encountered when 
installing the PD1200 Pole Display. 

Symptom 

Solutions 

The pole display does 
not have power. 

  For UT28XX POS Systems, if the pole has an RS232 connector, 

make sure it is not plugged into the COM1 port. There is no +5 on 
pin 9 of this port. Use the COM2 -6 ports. 

  If using a wall transformer, make sure it is plugged into the AC 

power source and into the power jack on the pole interface cable. 

Meaningless characters 
appear on the pole 
display when I run my 
application. 

  For RS232 Devices, check the baud-rate settings for the application 

to ensure that they match the settings for the pole display. 

Note: 

Please call UTC RETAIL Technical Support at 800.349.0546, if you have any problems not addressed in the 
Troubleshooting Procedures, or have questions about other sections of this documentation. 

 