Mount the detector on a stable surface up to 25 ft. (7.6 m)
from the farthest point on the glass surface.
•
Avoid locations that expose the detector to possible false
alarm sources such as:
•
Glass airlocks and vestibule areas
• Kitchens
•
Residential car garages
•
Small utility rooms
• Stairwells
• Bathrooms
•
Small acoustically live rooms
• Air
vents
Multiple window coverage
The detector has a 360 degree coverage pattern that can be
used to cover several windows in a single room. To use this
coverage pattern, do the following:
1. Draw an imaginary line from the center of each window to
be covered in toward the center of the room.
2. Mount the detector on the ceiling as close as possible to
where the lines intersect (Figure 3 below).
Figure 3: Multiple window coverage
Ceiling
mount
Detector
60 max.
60 max.
Do not mount the detector at more than a 60 degree angle
from the center of any window to be protected.
Installation
All wiring must conform to the National Electric Code (NEC)
and/or local codes having jurisdiction.
Caution:
If you are unsure about location, connect a 9V
battery to the detector and test it before permanently mounting
the detector.
To install the detector, do the following:
1. Run the security system wiring to the detector location.
2. Remove the front cover of the detector as follows:
Round housing
Press the release tab on the lip of the base, twist the cover
counter clockwise, and lift the cover off (Figure 4 below).
Figure 4: Round housing parts
Microphone
LED
Release tab
Rectangle housing
Insert a flat-blade screwdriver into the slot on the bottom of the
cover and gently pry up to unlock the cover. Grasp the bottom
of the cover and lift up until the cover plate is in the open
Figure 5: Detector knockout locations
J3
Spring clip
Knockouts
J3
Spring clip
Slot
Knockouts
3. Set the range with J3 spring clip on the circuit board. See
4. Remove the appropriate wiring and mounting knockout
holes from the base. See Figure 5 above for rectangle
housings and round housings.
5. Pull the wires through the knockout holes and use two
screws to attach the base to the surface. Use wall anchors
if necessary.
6. Strip 3/8 in. of insulation from each wire.
7. Connect the system wires to the appropriate screw
terminals on the base and tighten the screws (Figure 6 on
page 3).
2
ShatterPro 3 Glassbreak Detector Installation Instructions