Mount the detector on a stable surface up to 25 ft. (7.6 m) 

from the farthest point on the glass surface. 

• 

Avoid locations that expose the detector to possible false 

alarm sources such as: 

 

• 

Glass airlocks and vestibule areas 

 • Kitchens 

 

• 

Residential car garages 

 

• 

Small utility rooms 

 • Stairwells 

 • Bathrooms 

 

• 

Small acoustically live rooms 

 • Air 

vents 

Multiple window coverage 

The detector has a 360 degree coverage pattern that can be 

used to cover several windows in a single room. To use this 

coverage pattern, do the following: 

1.  Draw an imaginary line from the center of each window to 

be covered in toward the center of the room. 

2.  Mount the detector on the ceiling as close as possible to 

where the lines intersect (Figure 3 below). 

Figure 3: Multiple window coverage 

Ceiling
mount

Detector

60  max.

60  max.

 

Do not mount the detector at more than a 60 degree angle 

from the center of any window to be protected. 

Installation 

All wiring must conform to the National Electric Code (NEC) 

and/or local codes having jurisdiction. 

Caution: 

If you are unsure about location, connect a 9V 

battery to the detector and test it before permanently mounting 

the detector. 

To install the detector, do the following: 

1.  Run the security system wiring to the detector location. 

2.  Remove the front cover of the detector as follows: 

Round housing 

Press the release tab on the lip of the base, twist the cover 

counter clockwise, and lift the cover off (Figure 4 below). 

Figure 4: Round housing parts 

Microphone

LED

Release tab

 

Rectangle housing 

Insert a flat-blade screwdriver into the slot on the bottom of the 

cover and gently pry up to unlock the cover. Grasp the bottom 

of the cover and lift up until the cover plate is in the open 

position (Figure 5 below). 

Figure 5: Detector knockout locations 

J3

 Spring clip

Knockouts

J3

 Spring clip

Slot

Knockouts

 

3.  Set the range with J3 spring clip on the circuit board. See 

Range settings” on page 3. 

4.  Remove the appropriate wiring and mounting knockout 

holes from the base. See Figure 5 above for rectangle 

housings and round housings. 

5.  Pull the wires through the knockout holes and use two 

screws to attach the base to the surface. Use wall anchors 

if necessary. 

6.  Strip 3/8 in. of insulation from each wire. 

7.  Connect the system wires to the appropriate screw 

terminals on the base and tighten the screws (Figure 6 on 

page 3). 

2  

ShatterPro 3 Glassbreak Detector Installation Instructions 

Summary of Contents for interlogix ShatterPro 3

Page 1: ...base to prevent tampering Hand clap test In addition to a test mode you can test the detector by clapping your hands Optional tamper switch Sends a signal to the control panel when the cover is removed from the base You will need the following tools and parts to install the detector ShatterPro 3 detector including cover screw Screws and wall anchors Flat blade screwdriver Phillips screwdriver UTC ...

Page 2: ... test it before permanently mounting the detector To install the detector do the following 1 Run the security system wiring to the detector location 2 Remove the front cover of the detector as follows Round housing Press the release tab on the lip of the base twist the cover counter clockwise and lift the cover off Figure 4 below Figure 4 Round housing parts Microphone LED Release tab Rectangle ho...

Page 3: ...are unsure about the glass type 2 To put the detector in test mode hold the tester so that the speaker is within 1 in 25 mm of the detector microphone Figure 8 below and activate the tester When the detector is in test mode the LED on the detector lights steady for 4 seconds and then flashes for 60 seconds The relay opens for 4 seconds then returns to standby Time resets after each valid test Figu...

Page 4: ... to keep it free of dust and dirt Always test the detector after cleaning it Specifications Input voltage 9 5 to 16 VDC Current Typical Maximum 15 mA 25 mA Electrical configuration Form A Form C Relay rating 16 V 50 mA max Tamper switch rating 12 V 50 mA max Detection range 3 to 25 ft 0 9 to 7 6 m x 360 Alarm response 4 seconds Minimum glass size 12 x 24 in 30 5 x 61 cm Recommended glass thickness...

Page 5: ...D PRODUCTS For more information on warranty disclaimers and product safety information please check https firesecurityproducts com policy product warning or scan the QR code Certification European Union directives UTC Fire Security hereby declares that this device is in compliance with the applicable requirements and provisions of the Directive 2014 30 EU and or 2014 35 EU For more information see...

Reviews: