UTC Fire and Security Interlogix NX-8E Installation Manual Download Page 1

 

P/N  I-NX8E-IM 

• REV C • ISS NOV12 

NX-8E Control Panel 
Installation Manual 

Summary of Contents for Interlogix NX-8E

Page 1: ...P N I NX8E IM REV C ISS NOV12 NX 8E Control Panel Installation Manual ...

Page 2: ...t For the latest documentation contact your localsupplier or visit us online at www utcfireandsecurity com This publication may contain examples of screen captures and reports used in daily operations Examples may include fictitious names of individuals and companies Any similarity to names and addresses of actualbusinessesor personsis entirely coincidental Trademarks andpatents Other trade names ...

Page 3: ...8 Chapter 3 Troubleshooting 59 General diagnosis 60 Trouble conditions 60 Voltage tables 63 Specifications 64 Appendix A Reporting codes 65 Reporting fixed codes in Contact ID and SIA 66 Reporting zone codes in Contact ID and SIA 68 Reporting Ademco Contact ID transmissions 69 Device numbers for reporting expander troubles 70 Zone ID or user ID hex digit for 4 2 formats 72 Appendix B Programming w...

Page 4: ...erview of the product and detailed instructions explaining how to install the NX 8E board inside the enclosure and how to program the control panel To use this document effectively you should have the following minimum qualifications A basic knowledge of electrical wiring and low voltage electrical connections A basic knowledge of control panels ...

Page 5: ...1 Introduction Summary This chapter provides an overview of your NX 8E Control Panel including basic installation and terminal connections Content Product overview 2 Product contents 2 Board installation 3 Wiring 3 Terminal descriptions 5 Module list 6 ...

Page 6: ...t partitions Integrated fire and input output modules Fast SIA and Contact ID formats System expansion with up to 32 modules Keypads can include NX 148E RF keypads that have built in wireless receivers Figure 1 NX 8E Control Panel 9 1 2 3 4 5 6 7 8 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Unit enclosure LED keypad Product contents The NX 8E Control Panel generally comes with One metal enclosur...

Page 7: ...e terminal strip is toward the front opening toward you to allow for the wire connections Figure 2 Board installation Wiring Table 1 below lists wire lengths for one keypad at the end of the wire When connecting more than one keypad to the end of the wire a higher gauge wire is required Table 1 Maximum keypad wire run Length in feet Wire gauge for NX 8E Wire gauge for NX 320 E 250 24 22 500 20 18 ...

Page 8: ...Chapter 1 Reporting codes 4 NX 8E Control Panel Installation Manual Figure 3 NX 8E wiring diagram ...

Page 9: ...t to the common terminal on the keypads and the expanders KP POS Connect to the POS terminal on the keypads and the expanders Individually this terminal is limited to 1 amp Combined this terminal and AUX PWR are limited to 2 amps total current SMOKE Smoke detector power 12 VDC 1 5 amps maximum for those jurisdictions that allow the priority zone to be used with smoke detectors COM Connect negative...

Page 10: ...s that are compatible with the NX 8E system Additional information is available from customer support Table 3 Module list Part number Description NX 8E NX 8E control only NX 848 KIT NX 8E control NX 148 LED keypad 16 5 V 40 VA transformer NX 108E 8 zone LED keypad NX 116E 16 zone LED keypad NX 124E 24 zone LED keypad NX 148E Alphanumeric 48 zone LCD keypad NX 200 Zone doubling kit includes one hun...

Page 11: ...1192E 192 zone LCD keypad NX 1208E 8 zone LED keypad NX 1248E 48 zone LCD keypad NX 1308E 8 zone LED door design keypad NX 1316E 16 zone LED door design keypad NX 1324E 24 zone LED door design keypad NX 1448E 48 zone fixed language icon keypad Note The maximum number of zones available is 192 regardless of the devices added Information regarding zone doubling is located in the Glossary ...

Page 12: ......

Page 13: ...l programming 14 Programming data types 16 Loading factory defaults 17 Enrolling modules and keypads 17 Programming locations 18 Quick start programming 18 Locations 0 to 18 Reporting 18 Locations 19 to 22 Downloading 26 Locations 23 and 24 Partition features 28 Locations 25 to 36 Zone type and partition selection 29 Location 37 Siren and system supervision 34 Location 38 Swinger shutdown count 35...

Page 14: ...d days 41 Locations 56 to 83 4 2 format communicator codes 42 Location 84 Daylight saving time 44 Locations 88 to 109 Partition account codes and features 45 Locations 110 to 169 Zone type characteristics 48 Locations 170 to 205 Zones 49 to 192 51 Location 206 Auto disarm day selection 55 Location 207 Serial port selector 55 Locations 208 to 211 Home automation system 55 Location 212 LCD keypad ad...

Page 15: ...Service LED begins flashing You can now toggle LEDs 1 to 8 on off to enable disable the functions shown in Table 4 below 3 Press after enabling disabling the desired functions Table 4 LED 1 to 8 functions LED Keypad feature enabled 1 Reserved Do not program this LED 2 Enable silent keypad option Silences the entry exit sounder and chime only 3 Enable ding dong sound for chime If off chime is a sin...

Page 16: ... the partition number 1 to 8 for the keypad The keypad will automatically exit this mode at this time Elapsed increments To set the elapsed increments since the last autotest 1 Enter 9 5 program code The Service LED begins flashing 2 Enter the three digit increment number 100 s digit 10 s digit 1 s digit System date To set the system date 1 Enter 9 6 master code The Service LED begins flashing 2 E...

Page 17: ... repeat the process 4 Press while the Ready LED is flashing to exit the user code programming mode User authority level To assign user authority levels 1 Enter 6 master code The Ready LED begins flashing 2 Enter the two digit user number The Ready LED illuminates and the Instant LED begins flashing 3 Turn on the LED for the features you want See Table 5 on page 14 for a description of each LED 4 E...

Page 18: ...de has access to the same partitions as the code being added changed Consequently when programming the user codes for a partitioned system leave at least one code can be go to program code if enabled in Location 43 access to all partitions or you will not be able to add new users If you want the end user to be able to add new codes you must remove the partition authority from all blank codes Enter...

Page 19: ...cess any location enter the desired programming location followed by If the location is a valid location the Armed LED extinguishes the Ready LED illuminates and the binary data for the first segment of the location is shown by the Zone LEDs While entering new data the Ready LED begins flashing to indicate a data change in process 2 Press to store the newly entered data The keypad advances to the ...

Page 20: ...om 0 to 15 or 0 to 255 depending on the location s segment Feature selection Used to turn features on or off Numerical data Program numerical data by entering a number from 0 to 255 on the numeric keys of the system keypad To view the data in a location a binary process is used The binary process uses the LEDs for zones 1 to 8 To determine the data in a programming location the binary process adds...

Page 21: ...nt of a location and press to enter the data you exit that location This turns the Ready LED off and the Armed LED on You are now ready to enter another programming location Loading factory defaults To load factory defaults enter program mode enter the device address and number and then enter 9 1 0 The keypad beeps three times indicating that loading is in progress The process takes about 6 second...

Page 22: ...Number of rings to answer Location 21 Download control Location 22 Download call back number Location 23 Feature report selection partition feature selection Location 24 Entry exit times Location 25 Zone type selection for zones 1 to 8 Location 37 System reporting operation and siren options Location 38 Swinger shutdown count Location 39 Keypad sounder control Location 40 System timers Location 42...

Page 23: ... create a special format in addition to the entries in Location 18 The default is 0 If this location contains a 0 the built in communicator is disabled and the NX 8E functions as a local only control Table 6 Communicator formats Data Format Description 0 Local Communicator is disabled 1 Universal 4 2 Two digit event code 1800 Hz transmit 2300 Hz handshake double round parity 40 pulses per second p...

Page 24: ...backup control for phone 1 The default is 0 0 The NX 8E will make the designated number of attempts to phone 1 before setting the fail to communicate condition to stop reporting 1 The NX 8E will stop trying to communicate after the designated number of attempts have been made to phone 1 2 The NX 8E will make the dial attempts in increments of two The first two attempts are made to phone 1 the next...

Page 25: ...ased upon the partition 1 to 8 regardless of the event Enter 1 for partition 1 through 8 for partition 8 If this location is used Location 4 should be programmed as 0 Location 6 Phone 2 Location 6 has 20 segments of numerical data Use this location to program phone 2 The default for each segment is 14 To program a delay of 4 seconds enter 13 in the appropriate segment To program tone dialing enter...

Page 26: ...he notification process The default is 8 which means that the communicator makes eight attempts to the first number Segment 2 Phone 2 backup control Program the backup control for phone 2 The default is 0 0 The NX 8E will make the designated number of attempts to phone 2 before setting the fail to communicate condition to stop reporting 1 The NX 8E will stop trying to communicate after the designa...

Page 27: ...t Enter 1 for partition 1 through 8 for partition 8 If this location is used Location 10 should be programmed as 0 Location 12 Phone 3 Location 12 has 20 segments of numerical data Use this location to program phone 3 The default for each segment is 14 To program a delay of 4 seconds enter 13 in the appropriate segment To program tone dialing enter 15 in the segment where tone dialing begins If th...

Page 28: ... the notification process The default is 8 which means that the communicator makes eight attempts to the first number Segment 2 Phone 3 backup control Program the backup control for phone 3 The default is 0 0 The NX 8E will make the designated number of attempts to phone 3 before setting the fail to communicate condition to stop reporting 1 The NX 8E will stop trying to communicate after the desig...

Page 29: ...8 Reserved Location 17 Phone 3 partitions reported Location 17 has one segment of feature selection data Use this location to program when events are to be reported to a phone number are based upon the partition 1 to 8 regardless of the event Enter 1 for partition 1 through 8 for partition 8 If this location is used Location 16 should be programmed as 0 Location 18 Custom communicator format Locat...

Page 30: ...eserved Locations 19 to 22 Downloading Location 19 Download access code Location 19 has eight segments of numerical data Use this location to program the eight digit access code that the NX 8E must receive from the downloading software before the panel permits downloading to occur The defaults for the segments are 8 4 8 0 0 0 0 0 Location 20 Download number of rings to answer Location 20 has one s...

Page 31: ...wnload software 8 On enables call back at autotest interval Location 22 Download call back number Location 22 has 20 segments of numerical data Use this location to enable the control panel to hang up for approximately 36 seconds ensuring that the calling party has disconnected before calling back For the control panel to perform this operation you need to program a telephone number into this loca...

Page 32: ...d aux 2 emergency panic 8 On enables keypad multiple code attempt tamper Segment 2 1 On enables LED extinguish 2 On enables require code for bypassing 3 On enables zone bypassed sounder alert 4 On enablesAC power low battery sounder alert 5 On enables bypass toggle 6 On enables silent autoarm 7 On enables automatic instant 8 On enables instant mode toggle Segment 3 1 On enables opening and closing...

Page 33: ...mming and are only to be changed with a thorough understanding of the operation of each bit Caution We recommend the installer bench test any custom zone types to ensure proper operation prior to making changes to a live system Use zone types 17 through 20 for wireless or for hardwired zones using European double EOL configurations Table 7 Zone types Zone type Description 1 Day zone Instant when t...

Page 34: ...tripped the system is armed and the Stay LED is on 14 Entry exit delay 1 with group bypass A trip starts entry delay 1 This zone bypasses when the group bypass command is entered at the keypad The lack of a trip during exit delay enables the automatic bypass or instant mode if programmed 15 Interior follower with group bypass Instant when the system is armed and no entry or exit delays are being t...

Page 35: ... in Segment 1 of Location 23 27 Interior follower force armable Instant when the system is armed and no entry or exit delay is being timed It is delay 1 time during entry and exit It automatically bypasses if enabled in Segment 1 of Location 23 28 Entry exit force armable delay 2 A trip starts entry delay 2 The lack of a trip during exit delay enables the automatic bypass or instant mode if progra...

Page 36: ...gment 1 for zone 17 segment 2 for zone 18 etc The segment defaults are 6 6 6 6 6 6 6 6 Location 30 Zones 17 to 24 partition Location 30 has eight segments of feature selection data Use this location to select the partitions 1 to 8 that zones 17 to 24 reside in Each segment corresponds to a zone segment 1 to zone 17 segment 2 to zone 24 etc In each segment enter 1 for partition 1 through 8 for part...

Page 37: ...48 Use segment 1 for zone 41 segment 2 for zone 42 etc The segment defaults are 6 6 6 6 6 6 6 6 Location 36 Zones 41 to 48 partition Location 36 has eight segments of feature selection data Use this location to select the partitions 1 to 8 that zones 41 to 48 reside in Each segment corresponds to a zone segment 1 to zone 41 segment 2 to zone 42 etc In each segment enter 1 for partition 1 through 8...

Page 38: ...ne off for zones to restore when the siren times out 4 On if dynamic battery test performed at arming off if performed at disarming 5 On if battery missing test is done every 12 seconds otherwise panel tests at midnight 6 On if manual bell test is done during 4 4 test function 7 On if manual communicator test is done during 4 4 test function 8 On enables box tamper terminals on the panel Segment 3...

Page 39: ...ion to program the number of trips during an arming cycle that the NX 8E allows before bypassing a zone The default is 1 Location 39 Keypad sounder control Location 39 has one segment of feature selection data Segment 1 1 On if keypad sounds for a telephone line cut when the system is armed 2 On if keypad sounds for a telephone line cut when the system is disarmed 3 On if keypad sounds upon AC pow...

Page 40: ...ures Location 41 has one segment of feature selection data Segment 1 1 On enables the six digit code option If enabled all arm disarm codes and the go to program code are six digits The default user 1 code is 123456 Caution If you enable this option verify that the go to program code is a six digit code before exiting programming 2 On requires code entry for 9 8 dial call back phone number and 9 9...

Page 41: ... 3 4 On enables go to program code for partition 4 5 On enables go to program code for partition 5 6 On enables go to program code for partition 6 7 On enables go to program code for partition 7 8 On enables go to program code for partition 8 All segment 2 features must be on for the go to program code to be used to change user codes Location 44 Duress code Location 44 has six segments of numerica...

Page 42: ...put 1 event and times Location 47 has two segments of numerical data Segment 1 Use Table 8 on page 39 to select the event that activates auxiliary output 1 Default is 0 Segment 2 Program the timing from 0 to 255 minutes or seconds depending on data programmed in Location 46 segment 1 Programming a 0 makes the output follow the event Default is 10 seconds Location 48 Auxiliary output 2 event and ti...

Page 43: ...ouble a 4 Tamper alarm a 5 Yelping siren burglary 6 Temporal siren fire 7 Any siren 8 Any bypass 9 AC fail 10 Low battery does not include expansion battery 11 Duress a 12 Aux 1 keypad zone keypad fire panic a 13 Aux 2 keypad zone keypad emergency panic a 14 Panic keypad zone keypad police panic a 15 Keypad tamper 16 Autotest a 17 Alarm memory 18 Entry 19 Exit 20 Entry or exit 21 Armed state follo...

Page 44: ...respectively c Events 49 and 50 require one or more of the following to operate NX 148E RF NX 408E NX 448E wireless receivers NX 548E or NX 1700E NX 1710E card readers Location 51 Autotest control Location 51 has four segments of numerical data Segment 1 Program the autotest interval Enter 0 if the interval is in days if the panel tests once daily program one day rather than once every 24 hours En...

Page 45: ... program the time 24 hour format in which the NX 8E disables the disarm capability for codes designated as arm only after closing This is also the time the automatic arming sequence begins if enabled in Location 55 Segment 1 Program the hour in military time of the closing autoarm time Default is 20 Segment 2 Program the minutes after the hour of the closing autoarm time Default is 0 Location 54 D...

Page 46: ... 8 Disable 45 minute retry timer Locations 56 to 83 4 2 format communicator codes Use Locations 46 to 83 only when reporting events to a pager or using a slow format such as 4 2 When using Contact ID or SIA you do not need to program these locations There are eight segments of numerical data for each location and the default for all segments is 0 The digit programmed in each of the segments in the...

Page 47: ...iary 2 emergency is enabled Location 23 Location 65 Keypad police panic communicator code Program the digits for a 4 2 format if the keypad panic is enabled Location 23 Location 66 Keypad multiple code entry tamper communicator code Program the digits sent for a 4 2 format if the keypad multiple code entry tamper is enabled Location 23 Location 67 Box tamper restore communicator code Program the d...

Page 48: ...ort is enabled Location 23 for each partition 1 to 8 Location 78 Closing communicator code Program the digits sent for a 4 2 format if the closing report is enabled Location 23 for each partition 1 to 8 Location 79 Autotest communicator code Program the digits sent for a 4 2 format if the autotest or manual test is enabled Location 37 Location 80 Recent closing and exit error communicator code Pro...

Page 49: ... to 12 Default is 3 Segment 2 Daylight saving time starting Sunday 1 to 4 first to fourth Default is 2 Segment 3 Daylight saving time ending month 1 to 12 Default is 11 Segment 4 Daylight saving time ending Sunday 1 to 4 first to fourth Default is 1 Locations 85 to 87 Reserved Locations 88 to 109 Partition account codes and features If a location is left unprogrammed the feature for partition 1 an...

Page 50: ...he segment immediately after the last digit of the account number If the account code is six digits long program all six segments Location 93 Partition 3 feature and reporting selection Location 93 has five segments of feature selection data Use this location to enable certain features that are accessed or visible to the user from the system keypad In addition certain communicator reports are enab...

Page 51: ...se this location to enable certain features that are accessed or visible to the user from the system keypad In addition certain communicator reports are enabled at this location Each of these features can be enabled by partition Location 23 Location 103 Partition 6 entry and exit times Location 103 has six segments of numerical data Use this location to program the entry exit times for partition 6...

Page 52: ...9 lists the attributes for each location Caution We recommend the installer bench test any custom zone types to ensure proper operation prior to making changes to a live system Even numbered locations Each even numbered location has one segment of numerical data that programs the alarm event code for Contact ID or SIA If 4 2 format is used the number programmed in this location is sent as the uppe...

Page 53: ...down see Location 38 7 On enables restore reporting 8 On enables listen in see Location 40 Segment 4 1 Enables zone activity monitor see Location 40 2 On enables end of line resistor defeat on zones that are not fire or keyswitch zones 3 On enables zone to act as request to exit input disables for alarm activation 4 On enables zone to act as access entry point Do not enable this segment unless con...

Page 54: ...0 0 132 12 Alarm code 5 133 12 Feature selection 457 125 45678 0 0 134 13 Alarm code 4 135 13 Feature selection 0 12458 5678 0 0 136 14 Alarm code 7 137 14 Feature selection 5 12456 5678 0 0 138 15 Alarm code 5 139 15 Feature selection 457 1256 5678 0 0 140 16 Alarm code 4 141 16 Feature selection 0 123456 5678 0 0 142 17 Alarm code 7 143 17 Feature selection 5 1245 25678 0 0 144 18 Alarm code 5 1...

Page 55: ... for zones 49 to 56 Use segment 1 for zone 49 segment 2 for zone 50 etc The segment defaults are 6 6 6 6 6 6 6 6 Location 171 Zones 49 to 56 partition Location 171 has eight segments of feature selection data Use this location to select the partitions 1 to 8 that zones 49 to 56 reside in Each segment corresponds to a zone segment 1 to zone 49 segment 2 to zone 50 etc In each segment enter 1 for pa...

Page 56: ... Use segment 1 for zone 81 segment 2 for zone 82 etc The segment defaults are 6 6 6 6 6 6 6 6 Location 179 Zones 81 to 88 partition Location 179 has eight segments of feature selection data Use this location to select the partitions 1 to 8 that zones 81 to 88 reside in Each segment corresponds to a zone segment 1 to zone 81 segment 2 to zone 82 etc In each segment enter 1 for partition 1 through 8...

Page 57: ... Use segment 1 for zone 121 segment 2 for zone 122 etc The segment defaults are 6 6 6 6 6 6 6 6 Location 189 Zones 121 to 128 partition Location 189 has eight segments of feature selection data Use this location to select the partitions 1 to 8 that zones 121 to 128 reside in Each segment corresponds to a zone segment 1 to zone 121 segment 2 to zone 122 etc In each segment enter 1 for partition 1 t...

Page 58: ... Use segment 1 for zone 161 segment 2 for zone 162 etc The segment defaults are 6 6 6 6 6 6 6 6 Location 199 Zones 161 to 168 partition Location 199 has eight segments of feature selection data Use this location to select the partitions 1 to 8 that zones 161 to 168 reside in Each segment corresponds to a zone segment 1 to zone 161 segment 2 to zone 162 etc In each segment enter 1 for partition 1 t...

Page 59: ... of feature selection data Use this location to program which days the system autodisarms If a zone is faulted when the panel tries to autodisarm the zone is bypassed 1 Sunday 2 Monday 3 Tuesday 4 Wednesday 5 Thursday 6 Friday 7 Saturday 8 Reserved Location 207 Serial port selector Location 207 has one segment of feature selection data Use this location to enable the serial port operations 0 Disab...

Page 60: ...ocation 210 Transition based broadcasts Location 210 has two segments of feature selection data The NX 8E can be programmed to automatically send information to the home automation system whenever there has been a change in this informaiton This is referred to as transition based broadcasting Which information packets use transition based broadcasting is dependent upon the application and the capa...

Page 61: ...rity of your system when programming this location Segment 1 1 Reserved 2 Interface configuration request 3 Reserved 4 Zone name request 5 Zone status request 6 Zone snapshot request 7 Partition status request 8 Partitions snapshot request Segment 2 1 System status request 2 Send X 10 message 3 Log event request 4 Send keypad text message 5 Keypad terminal mode request 6 to 8 Reserved Segment 3 1 ...

Page 62: ...ion 1 keypad 1 This will allow Location 212 to be left at the factory default If the LCD keypad is selected as something other than parition 1 keypad 1 program the appropriate address in Location 212 Table 10 LCD keypad addresses Keypad Partition number 1 2 3 4 5 6 7 8 1 192 193 194 195 196 197 198 199 2 200 201 202 203 204 205 206 207 3 208 109 210 211 212 213 214 215 4 216 217 218 219 220 221 22...

Page 63: ...on Manual 59 Chapter 3 Troubleshooting Summary This chapter provides product specifications and information to help you troubleshoot the product Content General diagnosis 60 Trouble conditions 60 Voltage tables 63 Specifications 64 ...

Page 64: ...d text is showing on one LCD keypad but not on the other keypads Make sure all keypads are addressed using the 9 4 commands Enter and exit programming to enroll the new device numbers From the keypad with text enter the following key sequence 9 2 installer code 1 Exit After approximately 30 seconds the text transfers to all keypads The control panel has an overcurrent service condition 1 The contr...

Page 65: ...ows lost zones This condition is usually caused by wireless zones not checking in with the panel Delete the zone and relearn it Go to Location 200 in the receiver Location 400 in the NX 148 RF to see what the signal strength is as the transmitter learned if the number shown is less than 6 relocate the transmitter or receiver for better reception The control panel does not try to dial the central s...

Page 66: ...ing exit time the panel assumes that the occupant has not left and bypasses the interior zones to prevent false alarms Turn off Location 23 Segment 1 bit 3 An open zone will not clear Take the zone out of all partitions For example to delete zone 9 1 Go to Location 28 Segment 1 and disable any bits that are on 2 Press to save 3 Exit programming Cell backup module does not work The NX 8E can only e...

Page 67: ...e seized AC to AC 17 5 VAC Data to common 6 VDC nominal 1 5 to 10 V fluctuates Keypad positive to common 13 5 VDC Aux power to common 13 5 VDC Battery to battery 13 5 VDC Table 12 Zone voltages 10 Zone condition Value Zones not doubled Open 13 VDC Good 3 3 kohm resistor 6 6 VDC Shorted 0 VDC Two wire smoke 680 ohm resistor 10 75 VDC Zones doubled Open 13 VDC Only low zone OK 3 74 kohm resistor 7 V...

Page 68: ...op Two wire smokes 300 ohms max 30 ohms max Built in siren driver Two tone temporal and yelp Loop response Selectable 50 mS or 500 mS Operating temperature 32 to 120 F 0 to 49 C LED keypad Current draw Without sounder Dimensions 130 mA max 55 mA 6 4 x 4 0 x 1 1 in 16 3 x 10 2 x 2 8 cm NX 148E LCD keypad Current draw Without sounder Dimensions 110 mA max 75 mA 6 4 x 5 3 x 1 0 in 16 3 x 13 5 x 2 5 c...

Page 69: ...rious events and transmissions associated with the NV 8V2 control panel Content Reporting fixed codes in Contact ID and SIA 66 Reporting zone codes in Contact ID and SIA 68 Reporting Ademco Contact ID transmissions 69 Device numbers for reporting expander troubles 70 Zone ID or user ID hex digit for 4 2 formats 72 ...

Page 70: ...b 312 YP Aux power overcurrent device number a 312 YQ Aux power restore device number a 137 TA Box tamper device number a 137 TR Box tamper restore device number a 570 U c Bypass restore zone number a 406 OC Cancel user number a 401 CL Close user number a 412 RS Download complete b 393 YX CleanMe 121 HA Duress b 451 OK Early open late close b 628 LX End program b 605 JL Event log full b 457 EE Exi...

Page 71: ... restore 384 XR Sensor battery restore zone number a 384 XT Sensor low battery zone number a 321 YH Siren restore device number a 321 YA Siren tamper device number a 627 LB Start program b 351 LT Telephone fault b 351 LR Telephone restore b 391 NA Zone activity fault b 391 NS Zone activity restore b 570 B c Zone bypass zone number a 137 TA Zone tamper zone number a 137 TR Zone tamper restore zone ...

Page 72: ...programmed in the zone type event code Locations 110 to 169 Table 14 Reporting zone codes Event code SIA code Description 0 HA Holdup alarm 1 FA Fire alarm 2 PA Panic alarm 3 BA Burglary alarm 4 BA Burglary alarm 5 BA Burglary alarm 6 UA Untyped alarm 7 BA Burglary alarm 8 BA Burglary alarm 9 UA Untyped alarm 10 HA Holdup alarm 11 MA Medical alarm 12 PA Panic alarm 13 TA Tamper alarm 14 RP Periodi...

Page 73: ...0 to 169 Table 15 Reporting Ademco Contact ID transmissions Event code Contact ID Description 0 122 Silent panic 1 110 Fire alarm 2 120 Panic alarm 3 130 Burglary alarm 4 131 Perimeter alarm 5 132 Interior alarm 6 133 24 hour burglary 7 134 Entry alarm 8 135 Day night alarm 9 150 Nonburglary 24 hour 10 121 Duress alarm 11 100 Medical alarm 12 123 Audible panic alarm 13 137 Tamper alarm 14 602 Peri...

Page 74: ... on Expander number reported 18 Zone 41 switch 1 and 3 on Expander number reported 19 Zone 49 switch 2 and 3 on Expander number reported 20 Zone 57 switch 1 2 3 on Expander number reported 21 Zone 65 switch 4 on Expander number reported 96 Zone 73 switch 1 and 4 on Expander number reported 97 Zone 81 switch 2 and 4 on Expander number reported 98 Zone 89 switch 1 2 4 on Expander number reported 99 ...

Page 75: ...r number reported 36 Switch 2 on Expander number reported 37 Switch 1 and 2 on Expander number reported 38 Switch 3 on Expander number reported 39 Switch 1 and 3 on Expander number reported 32 Switch 2 and 3 on Expander number reported 33 Switch 1 2 3 on Expander number reported 34 Output module for NX 570E 580E Switch 1 and 2 on Device address 24 Switch 3 on Device address 25 Switch 1 and 3 on De...

Page 76: ...ammed in these locations are sent as the upper hex digit in place of the alarm event code The zone ID or user ID are always reported as the lower hex digits The following table shows the hex digit for the zone user IDs For example if the zone user ID is 15 the 4 2 lower digit is F Table 18 Zone user ID and hex digit Zone user ID Hex digit Zone user ID Hex digit Zone ID Hex digit 1 1 2 2 3 3 4 4 5 ...

Page 77: ... 75 F 76 1 77 2 78 3 79 4 80 5 81 6 82 7 83 8 84 9 85 A 86 B 87 C 88 D 89 E 90 F 91 1 92 2 93 3 94 4 95 5 96 6 97 7 98 8 99 9 100 A 101 B 102 C 103 D 104 E 105 F 106 1 107 2 108 3 109 4 110 5 111 6 112 7 113 8 114 9 115 A 116 B 117 C 118 D 119 E 120 F 121 1 122 2 123 3 124 4 125 5 126 6 127 7 128 8 129 9 130 A 131 B 132 C 133 D 134 E 135 F 136 1 137 2 138 3 139 4 140 5 141 6 142 7 143 8 144 9 145 ...

Page 78: ... 4 170 5 171 6 172 7 173 8 174 9 175 A 176 B 177 C 178 D 179 E 180 F 181 1 182 2 183 3 184 4 185 5 186 6 187 7 188 8 189 9 190 A 191 B 192 C 193 D 194 E 195 F 196 1 197 2 198 3 199 4 200 5 201 6 202 7 203 8 204 9 205 A 206 B 207 C 208 D 209 E 210 F 211 1 212 2 213 3 214 4 215 5 216 6 217 7 218 8 219 9 220 A 221 B 222 C 223 D 224 E 225 F 226 1 227 2 228 3 229 4 230 5 231 6 232 7 233 8 234 9 235 A 2...

Page 79: ... Manual 75 Appendix B Programming worksheet Summary This appendix provides a programming worksheet that shows location defaults and provides space to record your installation settings Content Programming worksheet 76 Zone worksheet 98 ...

Page 80: ...wnload and log full Segment 2 1 Tampers 2 Short circuit and ground fault 3 Sensor lost 4 Sensor low battery 5 Expander trouble 6 Failure to communicate 7 Zone activity monitor 8 Reserved 5 Partitions reported to phone 1 Segment 1 Partitions 1 to 8 1 2 3 4 5 6 7 8 6 Phone 2 20 segments 14 each segment 7 Phone 2 account code 10 10 10 10 10 10 8 Phone 2 communicator format 0 9 Phone 2 dial attempts B...

Page 81: ...Reserved 7 ON 20 pps OFF 10 or 40 pps 8 ON 10 pps OFF 20 or 40 pps Segment 2 1 ON pager format 2 ON 1400 2300 handshake 3 and 4 Reserved 5 ON Contact ID 6 ON SIA 7 ON Contact ID or 4 3 8 ON DTMF 19 Download access code 8 4 8 0 0 0 0 0 20 Number of rings to answer 8 21 Download control Segment 1 1 Enable tw o callanswering machine defeat 2 Enable tone sniff answering machine defeat 3 Require callba...

Page 82: ...7 8 Segment 7 1 2 3 4 5 6 7 8 Segment 8 1 2 3 4 5 6 7 8 27 Zones 9 to 16 zone types 6 6 6 6 6 6 6 6 28 Zones 9 to 16 partitions Segment 1 1 2 3 4 5 6 7 8 Segment 2 1 2 3 4 5 6 7 8 Segment 3 1 2 3 4 5 6 7 8 Segment 4 1 2 3 4 5 6 7 8 Segment 5 1 2 3 4 5 6 7 8 Segment 6 1 2 3 4 5 6 7 8 Segment 7 1 2 3 4 5 6 7 8 Segment 8 1 2 3 4 5 6 7 8 29 Zones 17 to 24 zone types 6 6 6 6 6 6 6 6 30 Zones 17 to 24 p...

Page 83: ...one 4 Dynamic battery test upon arming 5 Battery missing test every 12 seconds 6 Manual bell testduring 4 4 test function 7 Manual communicator test during 4 4 test function 8 Box tamper enabled Segment 3 1 Box tamper report enabled 2 AC failreport enabled 3 Low battery report enabled 4 AUX pow er over current report enabled 5 Siren supervision report enabled 6 Telephone line cut report enabled 7 ...

Page 84: ...rt delay 0 to 255 minutes 5 minutes Segment 3 Pow er up delay 0 to 60 60 seconds Segment 4 Siren time 1 to 254 8 minutes Segment 5 Telephone line cut delay 0 to 255 0 seconds Segment 6 Cross zone time 0 to 255 5 minutes Segment 7 Chime time in 50 mS increments 0 to 255 3 Segment 8 Dialer delay 15 to 255 30 seconds Segment 9 Fire alarm verification time 120 to 255 0 seconds Segment 10 Listen in tim...

Page 85: ...le go to program code for partition8 44 Duress code 15 15 15 15 15 15 45 Auxiliary outputs 1 to 4 partition selection Segment 1 Output 1 partitions 1 2 3 4 5 6 7 8 Segment 2 Output 2 partitions 1 2 3 4 6 6 7 8 Segment 3 Output 3 partitions 1 2 3 4 5 6 7 8 Segment 4 Output 4 partitions 1 2 3 4 5 6 7 8 46 Auxiliary outputs 1 to 4 special timing Segments 1 to 4 outputs 1 to 4 Output 1 Output 2 Output...

Page 86: ...days or hours based on Segment 1 24 hours Segment 3 Hour of the autotest in 24 hour time format 2 0200 Segment 4 Autotest report time min after the hour 0 52 Opening automatic disarm times Segment 1 Hour of the opening time 8 Segment 2 Minutes after the opening time 0 53 Closing automatic arming times Segment 1 Hour of the closing auto arming time 20 Segment 2 Minutes after hour of closing auto ar...

Page 87: ... restore code 0 Segment 6 Partition 6 restore code 0 Segment 7 Partition 7 restore code 0 Segment 8 Partition 8 restore code 0 57 Bypass communicator code Segment 1 Partition 1 bypass code 0 Segment 2 Partition 2 bypass code 0 Segment 3 Partition 3 bypass code 0 Segment 4 Partition 4 bypass code 0 Segment 5 Partition 5 bypass code 0 Segment 6 Partition 6 bypass code 0 Segment 7 Partition 7 bypass ...

Page 88: ...4 Partition 4 sensor low battery code 0 Segment 5 Partition 5 sensor low battery code 0 Segment 6 Partition 6 sensor low battery code 0 Segment 7 Partition 7 sensor low batterycode 0 Segment 8 Partition 8 sensor low battery code 0 61 Sensor missing communicator code Segment 1 Partition 1 sensor missing code 0 Segment 2 Partition 2 sensor missing code 0 Segment 3 Partition 3 sensor missing code 0 S...

Page 89: ... Segment 2 Partition 2 opening code 0 Segment 3 Partition 3 opening code 0 Segment 4 Partition 4 opening code 0 Segment 5 Partition 5 opening code 0 Segment 6 Partition 6 opening code 0 Segment 7 Partition 7 opening code 0 Segment 8 Partition 8 opening code 0 78 Closing communicator code Segment 1 Partition 1 closing code 0 Segment 2 Partition 2 closing code 0 Segment 3 Partition 3 closing code 0 ...

Page 90: ...stant 8 Reserved Segment 3 1 Open close 2 Bypass 3 Restore 4 Trouble 5 Tamper 6 Cancel 7 Recent closing 8 Exit error Segment 4 1 Late to close early to open 2 to 8 Reserved Segment 5 Reserved 91 Partition 2 entry and exit times Segment 1 Entry time 1 0 Segment 2 Exit time 1 0 Segment 3 Entry time 2 0 Segment 3 Exit time 2 0 Segments 5 and 6 Reserved 92 Partition 3 account code 10 10 10 10 10 10 93...

Page 91: ...ion Segment 1 1 Quick arm 2 Re exit 3 Auto bypass 4 Silent panic 5 Audible panic 6 Auxiliary 1 7 Auxiliary 2 8 Multi keypress tamper Segment 2 1 LED extinguish enable 2 Require user code by bypassing zones 3 Bypass sounder alert 4 AC pow er low battery sounder alert 5 Enable bypass toggle 6 Enable silent auto arm 7 Enable auto instant 8 Reserved Segment 3 1 Open close 2 Bypass 3 Restore 4 Trouble ...

Page 92: ...arly to open 2 to 8 Reserved Segment 5 Reserved 100 Partition 5 entry and exit times Segment 1 Entry time 1 0 Segment 2 Exit time 1 0 Segment 3 Entry time 2 0 Segment 3 Exit time 2 0 Segments 5 and 6 Reserved 101 Partition 6 account code 10 10 10 10 10 10 102 Partition 6 feature and reporting selection Segment 1 1 Quick arm 2 Re exit 3 Auto bypass 4 Silent panic 5 Audible panic 6 Auxiliary 1 7 Aux...

Page 93: ...Multi keypress tamper Segment 2 1 LED extinguish enable 2 Require user code by bypassing zones 3 Bypass sounder alert 4 AC pow er low battery sounder alert 5 Enable bypass toggle 6 Enable silent auto arm 7 Enable auto instant 8 Reserved Segment 3 1 Open close 2 Bypass 3 Restore 4 Trouble 5 Tamper 6 Cancel 7 Recent closing 8 Exit error Segment 4 1 Late to close early to open 2 to 8 Reserved Segment...

Page 94: ...o 8 Reserved Segment 5 Reserved 109 Partition 8 entry and exit times Segment 1 Entry time 1 0 Segment 2 Exit time 1 0 Segment 3 Entry time 2 0 Segment 3 Exit time 2 0 Segments 5 and 6 Reserved 110 Zone type 1 alarm event code 8 111 Zone type 1 feature select Segment 1 1 Fire enable for fire zone 2 24 hour enable for non fire 24 hour 3 Keysw itch zone 4 Follow er enable for burg zones that are inst...

Page 95: ...vent code 5 117 Zone type 4 feature select 45 125 5678 0 0 118 Zone type 5 alarm event code 5 119 Zone type 5 feature select 457 125 5678 0 0 120 Zone type 6 alarm event code 4 121 Zone type 6 feature select 0 1245 5678 0 0 122 Zone type 7 alarm event code 0 123 Zone type 7 feature select 2 0 78 0 0 124 Zone type 8 alarm event code 1 125 Zone type 8 feature select 1 13 378 0 0 126 Zone type 9 alar...

Page 96: ... 21 feature select 24 15 78 0 0 152 Zone type 22 alarm event code 20 153 Zone type 22 feature select 24 15 78 0 0 154 Zone type 23 alarm event code 21 155 Zone type 23 feature select 24 15 78 0 0 156 Zone type 24 alarm event code 22 157 Zone type 24 feature select 1 13 378 0 0 158 Zone type 25 alarm event code 14 159 Zone type 25 feature select 248 45 0 0 0 160 Zone type 26 alarm event code 5 161 ...

Page 97: ...6 6 6 6 177 Zones 73 to 80 partitions Segment 1 1 2 3 4 5 6 7 8 Segment 2 1 2 3 4 5 6 7 8 Segment 3 1 2 3 4 5 6 7 8 Segment 4 1 2 3 4 5 6 7 8 Segment 5 1 2 3 4 5 6 7 8 Segment 6 1 2 3 4 5 6 7 8 Segment 7 1 2 3 4 5 6 7 8 Segment 8 1 2 3 4 5 6 7 8 178 Zones 81 to 88 zone types 6 6 6 6 6 6 6 6 179 Zones 81 to 88 partitions Segment 1 1 2 3 4 5 6 7 8 Segment 2 1 2 3 4 5 6 7 8 Segment 3 1 2 3 4 5 6 7 8 ...

Page 98: ...6 6 6 6 191 Zones 129 to 136 partitions Segment 1 1 2 3 4 5 6 7 8 Segment 2 1 2 3 4 5 6 7 8 Segment 3 1 2 3 4 5 6 7 8 Segment 4 1 2 3 4 5 6 7 8 Segment 5 1 2 3 4 5 6 7 8 Segment 6 1 2 3 4 5 6 7 8 Segment 7 1 2 3 4 5 6 7 8 Segment 8 1 2 3 4 5 6 7 8 192 Zones 137 to 144 zone types 6 6 6 6 6 6 6 6 193 Zones 137 to 144 partitions Segment 1 1 2 3 4 5 6 7 8 Segment 2 1 2 3 4 5 6 7 8 Segment 3 1 2 3 4 5 ...

Page 99: ...ns Segment 1 1 2 3 4 5 6 7 8 Segment 2 1 2 3 4 5 6 7 8 Segment 3 1 2 3 4 5 6 7 8 Segment 4 1 2 3 4 5 6 7 8 Segment 5 1 2 3 4 5 6 7 8 Segment 6 1 2 3 4 5 6 7 8 Segment 7 1 2 3 4 5 6 7 8 Segment 8 1 2 3 4 5 6 7 8 204 Zones 185 to 192 zone types 6 6 6 6 6 6 6 6 205 Zones 185 to 192 partitions Segment 1 1 2 3 4 5 6 7 8 Segment 2 1 2 3 4 5 6 7 8 Segment 3 1 2 3 4 5 6 7 8 Segment 4 1 2 3 4 5 6 7 8 Segme...

Page 100: ...e Segment 1 1 Reserved 2 Interface configuration request 3 Reserved 4 Zone name request 5 Zone status request 6 Zones snapshot request 7 Partition status request 8 Partitions snapshot request Segment 2 1 System status request 2 Send X 10 message 3 Log eventrequest 4 Send keypad text message 5 Keypad terminal mode request 6 to 8 Reserved Segment 3 1 Program data request 2 Program data command 3 Use...

Page 101: ...4 Part 5 Part 6 Part 7 Part 8 1 192 193 194 195 196 197 198 199 2 200 201 202 203 204 205 206 207 3 208 209 210 211 212 213 214 215 4 216 217 218 219 220 221 222 223 5 224 225 226 227 228 229 230 231 6 232 233 234 235 236 237 238 239 7 240 241 242 243 244 245 246 247 8 248 249 250 251 252 253 254 255 ...

Page 102: ...eet 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 ...

Page 103: ...11 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 ...

Page 104: ......

Page 105: ...sing or a low battery is detected Location 23 Arm disarm codes The NX 8E has eight four digit or six digit codes to arm disarm the control panel All codes must have the same number of digits The default for user 1 is 1234 when using a four digit code or 123456 for a six digit code Use this code to enter the new arm disarm codes Location 41 Automatic arming If programmed the NX 8E auto arms at a sp...

Page 106: ...n 37 Bypass toggle This feature enables the end user to toggle turn off on the bypass of an interior zone with the system armed by pressing the bypass key Location 23 Call back When enabled the control panel uses the call back phone number to call the download computer before beginning a download Location 21 Cancel When enabled the NX 8E sends a cancel report when the system is disarmed and the Ca...

Page 107: ...e the loop condition and an open on that zone produces a faulted condition Any priority zone ignores this feature Locations 110 to 169 Entry guard This unique low level arming mode reduces the most common source of false alarms When armed with the Instant LED on the opening of any zones designated as an entry guard zone initiates the keypad sounder and starts the entry delay before creating an ala...

Page 108: ...mmediate restore by zone If programmed the NX 8E sends alarm and restore reports as soon as they occur otherwise the NX 8E waits until the siren time expires Locations 37 and 40 Keypad activated panics The NX 8E has three keypad activated panics that send reports to the central station auxiliary 1 fire auxiliary 2 medical and keypad panic Auxiliary 1 activates the temporal fire siren auxiliary 2 s...

Page 109: ...g report to the central station if an alarm occurs within 2 minutes after the panel is armed The system always reports user 1 Location 23 Re exit The NX 8E has the ability to restart the exit delay for a quick exit without disarming the system by pressing the Exit key while the system is armed Location 23 Shutdown When enabled the keypads turn off all LEDs except the Power LED and does not accept ...

Page 110: ...37 Tone sniff answering machine defeat If enabled only one call is required to defeat the answering machine To use this feature you must have a Hayes 1200 Smart Modem From the computer call the panel as normal When the answering machine answers the panel hears the tones from the modem and seizes the phone line for a download Location 21 Two call answering machine defeat If enabled two telephone ca...

Page 111: ...asic system consisting of the main control panel and one keypad Additional devices include wireless receivers extra keypads etc If enabled this feature allows you to use the four zones on the panel as eight normally closed zones When this feature is used European double EOL configuration cannot be used Location 37 Note This feature does not increase the total number of available zones beyond fourt...

Page 112: ......

Page 113: ......