2NM/2NX/2NY/2NZ/2P0/2P6
1-3-27
U065
Adj Scn
Description
Adjusts the magnification of the original scanning.
Purpose
Make the adjustment if the magnification in the main scanning direction is incorrect.
Make the adjustment if the magnification in the auxiliary scanning direction is incorrect.
Caution
The magnification adjustment along the main scanning direction could cause black streaks
depending on the content of the original document.
Adjust the magnification of the scanner in the following order.
U065 (
main scanning
direction) -------- U065 (
auxiliary scanning direction
)
Method
1. Press the start key.
2. Press the system menu key.
3. Place an original and press the start key to make a test copy.
4. Press the system menu key.
5. Select the item to be adjusted.
Display
Description
Setting
range
Initial
setting
Change in
value per
step
Main Scan
Scanner magnification in the main
scanning direction.
-75 to 75
0
0.02%
Sub Scan
Scanner magnification in the auxiliary
scanning direction.
-125 to 125
0
0.02%
Adjustment: Main Scan
1. Change the setting value using the cursor right/left keys or numeric keys.
For copy example 1, increase the value. For copy example 2, decrease the value.
Increasing the setting enlarges the image and decreasing it narrows the image.
Figure 1-3-5
2. Press the start key. The value is set.
Original
Copy
example 1
Copy
example 2
Summary of Contents for P-4030 MFP
Page 7: ...This page is intentionally left blank ...
Page 13: ...This page is intentionally left blank ...
Page 19: ...2NM 2NX 2NY 2NZ 2P0 2P6 5 Installation Guide PF 320 Paper Feeder ...
Page 55: ...2NM 2NX 2NY 2NZ 2P0 2P6 1 2 24 This page is intentionally left blank ...
Page 386: ...2NM 2NX 2NY 2NZ 2P0 2P6 1 5 100 This page is intentionally left blank ...
Page 486: ...Installation Guide PF 320 Paper Feeder Installation Guide ...
Page 487: ...PF 320 㾌㙼 㾌㙼 PF 320 PF 320 PF 320 㪧㪝㪄㪊㪉㪇 㪧㪝㪄㪊㪉㪇䈱 㪧㪝㪄㪊㪉㪇G 㾌 㾌 PF 320 PF 320 ...