9. Remove two screws and then remove the
reverse unit front cover.
Figure 1-5-12
10. Remove the screw and then remove the
CIS.
11. Replace the CIS. Install the CIS to the DP.
12. Refit the reverse unit front cover to the DP.
13. Connect the connector of the DP timing
switch 2 and refit the original conveying
guide to the DP.
14. Connect the connector to the DP inverter
PWB and the flexible flat cable to the CIS
relay PWB.
15. Refit the original feed guide and the DP front
cover to the DP.
Figure 1-5-13
Reverse unit
front cover
CIS
CIS
Screw