UST PURE 2.4 Series Installation Operation Service Maintenance Download Page 2

- 2 - 

General Information regarding UV-C Radiation 

Ultraviolet light in the 200 to 280nm (nanometer) spectrum possesses a germ-reducing effect. The cell structure of bacteria, viruses, algae and other 
microorganisms is harmed most significantly by UVC radiation at 254nm wavelength. The genetic information (DNA) is modified in such way that 
microorganisms lose their ability to reproduce and eventually die.  

The light source used in your device produces that particular radiation. UV-disinfection does not require extensive dwell times since the process only 
takes a fraction of a second to complete.  

Technical Data 

Product 

Operating 

voltage 

Max. 

Pres-

sure 

Reactor 

Ballast 

Weight  

Max. Flow 

Rate 

Length* 

Ø 

Drain 

Connection 

Length 

Width 

Height 

PURE 2.4     40 W 

230 VAC 

6 bar 

1050 mm 

76 mm 

2“  AG 

250 

90 

160 

9,4 kg 

20 m³/h 

PURE 2.4     75 W 

230 VAC 

6 bar 

1050 mm 

76 mm 

2“  AG 

250 

90 

160 

9,4 kg 

50 m³/h 

PURE 2.4   120 W 

230 VAC 

6 bar 

1050 mm 

76 mm 

2“  AG 

250 

90 

160 

9,4 kg 

75 m³/h 

* incl. cable / cable gland 

Dimension 

 

Scope of Delivery 

The PURE 2.4 – UVC-units are supplied  ready for use. Please check whether the equipment is complete: 
 

Product

 

Lamp 

PVC Union 63 mm x  

2“ female 

Wall mounts 

PVC Cap 2“ 

PURE 2.4     40 W 

1 pc.   40 W 

2 pcs. 

2 pcs. 

1 pc. 

PURE 2.4     75 W 

1 pc.   75 W 

2 pcs. 

2 pcs. 

1 pc. 

PURE 2.4   120 W 

1 pc. 120 W 

2 pcs. 

2 pcs. 

1 pc. 

 

Safety 

Warning:

  Ultraviolet  light  can  cause  damage  to  eyes  and  skin.  Therefore,  you 

should never try to access the light source while the device is in operation. 

 

 

A LED display on the ballast housing indicates the operating status of the 

UVC  light source: 

                                             Green:     On

        

Red:    Off

 

 

If the red LED is lit the light source might be defective and must be replaced. If the red LED 
still lights up after the light source has been replaced you should contact the sales company 
or the manufacturer.  

 

If the main plug has been pulled or the power supply cut off (fixed installation) the LED will not 
light up. 

 

Never run your UVC unit without water and never cover it up in operation!  

 

The device is supplied with a 2-pin grounded  plug. If you want to use the device in a permanent installation, which may  

       be conducted only by a qualified electrician, you must adhere to all applicable legal regulations. 

  All local electrical regulations must be complied with.  

  The device must be protected by a RCD (residual current circuit breaker). 

 

For maintenance tasks (cleaning of quartz glass tube or changing the light bulb) the power and water supply must be interrupted (pull the power 
plug or deactivate the RCD).  

 

The UVC device must be protected against frost. If the device is filled with water the water must be drained. The device must be stored in a 
frost-free and dry place  