USSC King 2007B Owner'S Manual Download Page 3

3

SAFETY NOTICE: 

If this heater is not properly installed a house fire may result. For your safety, follow the 

installation directions. Contact local building or fire officials about restrictions and installation inspection 

requirements in your area.

read these rules and the instructions carefully.

1.  Check with local codes. The installation comply with their 

rulings.  Observe  closely  the  clearances  to  combustibles 

specified in this manual.

2.  Do not install this heater in a mobile home or trailer.

3. 

DO NOT

 connect a wood burning heater to an aluminum 

Type B gas vent.  This is not safe and is prohibited by the 

National Fire Protection Association Code.

4.  Always connect this heater to a chimney and vent to the 

outside. Never vent to another room or inside a building.

5.  The freestanding room heater requires a masonry or a UL 

Listed  Residential  Type  and  Building  Heating  Appliance 

Chimney.

6.  Be sure that your chimney is safely constructed and in good 

repair. Have the chimney inspected by the Fire Department 

or a qualified inspector. Your insurance company may be 

able to recommend a qualified inspector.

7.  Make sure the chimney is high enough to give a good draft.

8.  Inspect chimney connector and chimney twice monthly dur-

ing the heating season for any deposit of creosote or soot 

which must be removed (

see Chimney Maintenance

).

9. 

DO  NOT  BE  ALARMED  IF  HEATER  SMOKES  UPON 

INITIAL FIRING.  

The  special  paint  used  on  this  heater 

must be cured during initial firing.  This smoking will occur 

only on initial firing.

10.  CAST IRON PARTS MUST BE "SEASONED" TO AVOID 

CRACKING.  BUILD ONLY SMALL FIRES DURING THE 

FIRST FEW DAYS OF USE.

11.  To prevent injury, do not allow anyone to use this heater 

who is unfamiliar with the correct operation of the heater.

12.  For additional information on using your Room Heater safely, 

obtain a copy of the National Fire Protection Association 

(NFPA) publication "Chimneys, Fireplaces, and Solid Fuel 

Burning Appliances" NFPA No. 211(USA).

Caution! Do not touch the metal or glass surfaces of the heater until it has thoroughly cooled.

SAfETY RULES

13.  Disposal of Ashes- Place ashes in a metal container with a 

tight fitting lid. Keep the closed container on a non-combus-

tible floor  or on the ground, well away from all combustible 

materials. Keep the ashes in the closed container until all 

cinders have thoroughly cooled. The ashes may be buried 

in the ground or picked up by a refuse collector.

14.  Keep the firebox section free of excess ashes.

15.  Observe clearances to combustible materials specified in 

this manual to avoid a fire hazard.

16. 

CARING FOR PAINTED PARTS

- This heater has a painted 

jacket, which is durable but it will not stand rough handling 

or abuse. When installing your heater, use care in handling. 

Clean with soap and warm water when heater is not hot. 

DO NOT

 use any acids or scouring soap, as these wear 

and dull the finish.

 PAINT DISCOLORATION WILL OCCUR 

IF THE HEATER IS OVERFIRED. FOLLOW OPERATING 

INSTRUCTIONS CAREFULLY.

17.  The firebox walls in this heater may become slightly distorted 

over a period of use.  The slight distortion does not affect 

the operation of the unit.

18. 

CAUTION:  HOT WHILE IN OPERATION.  KEEP CHIL-

DREN, CLOTHING, AND FURNITURE AWAY.  CONTACT 

MAY CAUSE SKIN BURNS.

19. 

CAUTION:  DO NOT CONNECT TO ANY AIR DISTRIBU-

TION OR DUCT SYSTEM.

20. 

CAUTION:  STORE SOLID WOOD FUEL A SAFE DIS-

TANCE AWAY.  DO NOT STORE SOLID WOOD FUEL 

WITHIN  HEATER  INSTALLATION  CLEARANCES  OR 

WITHIN THE SPACE REQUIRED FOR ASH REMOVAL.

21. 

DO NOT USE A GRATE OR ELEVATE THE FIRE.

22. 

WE RECOMMEND THAT SMOKE DETECTORS BE IN-

STALLED IN YOUR HOME.

Summary of Contents for King 2007B

Page 1: ...a CAUTION Read All Instructions Carefully BeforeStartingTheInstallation or Operating This Heater Improper Installation Could Void Your Warranty EXEMPT PER EPA METHOD 28A TESTED TO UL 1482 SAVE THIS MANUAL FOR FUTURE REFERENCE THIS MANUAL WILL HELP YOU TO OBTAIN EFFICIENT DEPENDABLE SERVICE FROM THE HEATER AND ENABLE YOU TO ORDER REPAIR PARTS CORRECTLY KEEP IN A SAFE PLACE FOR FUTURE REFERENCE Pt N...

Page 2: ...ng Rule or Tape Measure Drill Hand or Electric Drill Bit 1 8 Dia For Sheet Metal Screws 5 16 Nut Driver or 5 16 Socket w Ratchet Screw Driver Blade Type Gloves Safety Glasses MATERIALS 6 Pipe 6 Elbow Collar and Thimble As Required 24 gauge min 1 2 Sheet Metal Screws No 10A x 1 2 6 Inside Diameter Underwriters Laboratories UL Listed Residential SolidFuelFactory BuiltTriplewallChimneyorExitingMasonr...

Page 3: ...ne to use this heater who is unfamiliar with the correct operation of the heater 12 ForadditionalinformationonusingyourRoomHeatersafely obtain a copy of the National Fire Protection Association NFPA publication Chimneys Fireplaces and Solid Fuel Burning Appliances NFPA No 211 USA CAUTION Do not touch the metal or glass surfaces of the heater until it has thoroughly cooled safety rules 13 Disposal ...

Page 4: ... Figures 2 3 4 You should have at least the clearances shown from the heater and the connector pipe to combustible surfaces If you have a solid brick or stone wall behind your heater you can place the heater as close as you wish to the wall If the wall is only faced with brick or stone treat it as a combustible wall LOCATING THE ROOM HEATER AS A LOCATION IS SELECTED KEEP THE FOLLOWING IN MIND MINI...

Page 5: ... comes equipped with a cast iron flue collar with holes to mount the solid damper as shown below Flue Collar 40292 Solid Damper 40398 5 16 18 x 1 1 2 Bolts 3 req Weld Tab 3 req Gasket MOUNTING CAST IRON FLUE COLLAR ...

Page 6: ...4 ASSEMBLY INSTRUCTIONS Step 1 THE BLOWER ASSEMBLY MUST BE DISCONNECTED FROM THE SOURCE OF ELECTRICAL SUPPLY BEFORE ATTEMPTING THE INSTALLATION With pliers cut the 6 micro joints and remove panel Note Discard the panel Step 2 Fix the assembly to the back of the stove with the four screws provided THE BLOWER ASSEMBLY IS INTENDED FOR USE ONLY WITH A STOVE THAT IS MARKED TO INDICATE SUCH USE DO NOT R...

Page 7: ...vent back puffing smoke spillage and to maximize performance Chimneysperformtwofunctions oneofwhich is apparent The chimney provides a means for exhausting smoke and flue gases result ing from combustion of the fuel Secondarily though the chimney provides Draft which allows oxygen to be continuously introduced intotheappliance sothatpropercombustionis possible As ofApril 1 1987 all wood heaters an...

Page 8: ...TION OF A WOOD HEATER Many prefabricated fireplaces fall into the zero clearance fireplace category This is a factory built metal fireplace with multi layered construc tion It is designed to provide enough insulation and or air cooling so that the base back and sides can be safely placed in direct contact with combustible floors and walls Although many prefabricated fireplaces have been tested by ...

Page 9: ...ch as a 6 flue outlet requires a 6 diameter for optimum drafting but can function well with an 8 but becomes borderline beyond an 8 diameter Masonry chimneys built of concrete blocks with or without flue liners do not meet modern build ing codes A solid fuel appliance must not be joined to a chimney flue which is connected to another appliance burning other fuels VENTING INTO A MASONRY CHIMNEY If ...

Page 10: ...ing sure that the thimble is flush with the inner flue lining secure the thimble in place with refractory mortar The thimble should be surrounded on all sides with 8 inches of brickwork solid masonry units or 24 inches of stone Install the stovepipe as far as possible into the thimble but not past the inside of the flue lining Thereshouldbeasmallairspace approximately 1 2 inch between the stovepip...

Page 11: ... 4 The pipe cannot extend into the chimney flue Fig 8 5 Seal each connector pipe joint with furnace cement Also seal the pipe at the chimney 6 Use 3 sheet metal screws at each joint to make the piping rigid 7 It is recommended that no more than two 2 90 degree bends be used in the stove pipe installation as more than two 2 may decrease the amount of draw and possibly cause smoke spillage 8 The chi...

Page 12: ...imney like water over a dam beating down the smoke The top of the chimney should be at least 3 feet above the roof and be at least to 2 feet higher than any point of the roof within 10 feet chimney maintenance Creosote Formation and Need for Removal When wood is burned slowly it produces tar and other organic vapors which combine with expelled moisture to form creosote The creosote vapors condense...

Page 13: ... Nickel 1 8 AC09185 Door Barrell Roller Ball Pin Assy 1 9 891108 Door Glass 1 N S 88087 Door Glass Gasket 6 ft 10 891114 Top Window Bracket 4 11 PL02715 Bottom Window Bracket 1 12 83033 Machine Screw 8 32 X 12 13 891213 Hinge Pad 1 N S 83274 Nut 3 8 16 2 N S 83045A Washer 2 14 25298 Baffle 1 15 891759 Hearth Trim Nickel 1 16 83431 Weld Tab 3 17 25307 Flue Collar 1 18 88042 Gasket Flue Collar 2 ft ...

Page 14: ...TION THE BLOWER ASSEMBLY MUST BE DISCONNECTED FROM THE SOURCE OF ELECTRICAL SUPPLY BE FORE ATTEMPTING ANY MAINTENANCE BRICKPLACEMENT TOPINSIDEVIEWOFFIREBOX 1 INSERT RIGHT LEFT SIDE FIREBRICK AS SHOWN 2 INSERT REAR FIREBRICK AS SHOWN 3 INSERTBOTTOM1 2FIREBRICKANDASHDUMPCOVER AS SHOWN 1 2 BRICK 1 2 BRICK ...

Page 15: ...combustible container Replace the ash pan after dumping the ashes ASHES SHOULD BE PLACED IN A METAL CONTAINER WITH A TIGHT FITTING LID THE CLOSED CONTAINER OF ASHES SHOULD BE PLACED ON A NONCOMBUSTIBLE FLOOR OR ON THE GROUND WELL AWAY FROM ALL COMBUSTIBLE MATERIALS PENDING FINAL DISPOSAL IF THE ASHES ARE DISPOSED OF BY BURIAL IN SOIL OR OTHERWISE LOCALLY DISPERSED THEY SHOULD BE RETAINED IN THE CL...

Page 16: ...umber which is on the nameplate attached to the heater when ordering repair parts always give the following informa tion as shown in this list 1 The part number 2 the part description 3 the model number 2007B 4 the serial number ____________________ how to order repair parts united states stove company 227 industrial park road p o box 151 south pittsburg tn 37380 423 837 2100 WWW USSTOVE COM C S S...

Reviews: