POWER: Keep ON, normal; OFF, abnormal.
WORK: Blink, normal; OFF, abnormal.
STA: This indicate the module working status. Keep ON after startup; Blink when connect with
network.
LINKA: This indicate the connection status of socket A. Keep ON when connecting; get OFF when
disconnect.
LINKB: This indicate the connection status of socket B. Keep ON when connecting; get OFF when
disconnect.
3.4.5. Reload by Hardware
By reload button, USR-G760c restore factory defaults or user set parameters
Reload to user default settings: Power on, press Reload button for 1-3s and release.
Reload to factory defaults: Power on, press Reload more than 6s and release.
3.4.6. Firmware Upgrade
Connect USR-G760c with PC by USB-RS232 cable, make sure the USR-G760c power is off now.
1. Open setup software “USR-G760 USR-G760 V1.0.0.392” or higher version, us default UART
parameters, select correct COM and click “Open Serial”
2. Click “Upgrade”, select correct firmware in the pop-up window
3. It shows “F,G,R” information in the software.
4. Press Reload button, power on USR-G760c, it will begin download firmware process, now release the
reload button. Until download finished, power off the USR-G760c. Then power on again.