LITHIUM Battery Models only  - The  LITHIUM  battery  is  warranted  to  last  for  10  years  under 

normal operating conditions. Replace the battery with only LITHIUM type: (ULTRALIFE: U9VL-J 

or Ultralife U9VL-J-P).
OPTIONAL BATTERY DRAWER TAMPER LOCKING PIN: To make your battery drawer tamper 

resistant, a locking pin has been provided (breakaway part on mounting bracket).
NOTE: If this feature has been activated, you will need to deactivate it by removing the battery 

drawer tamper pin located at side of battery drawer. Refer to Page 5.
Pull the QUICK DRAW

(R) 

battery drawer open and remove the battery. While observing polarity, 

push the replacement battery into the battery drawer until it is held securely in place. Carefully 

close  the battery drawer and reinstall the tamper pin.
Test the smoke alarm by pushing the TEST button on the smoke alarm cover until the alarm 

sounds, then release.

REPAIRS AND SERVICES

This smoke alarm contains less than 1 microcurie (37 kilobecquerel) of Americium 241, a radioactive 

material. 

The distribution of these ionization-type smoke alarms is licensed by the U.S. Nuclear 

Regulatory Commission; the consumer is exempt from any licensing or requirements.

 If the 

smoke alarm is defective in any way, do not tamper with the smoke alarm. Return the smoke alarm 

for servicing. (See warranty for instructions or in-warranty returns.) There will be a service charge 

for repairing out of warranty smoke alarms.

DEVELOP AND PRACTICE A PLAN OF ESCAPE

BASICS OF ESCAPE PLAN

o  Make a floor plan indicating all doors and windows and at least two escape routes from each 

room. Second story windows may need a rope or chain ladder.

o  Have a family meeting and discuss your escape plan, showing everyone what to do in case of 

fire.

o  Determine a place outside your home where all of you can meet if a fire occurs.

o  Familiarize everyone with the sound of the smoke alarm and train them to leave your home 

when they hear the sound.

o  Identify children's bedrooms with red stickers placed in the upper left corner of the windows. 

They are available from your local fire department.

o  Practice a fire drill at least every six months. Practice allows you to test your plan before an 

emergency. You may not be able to reach your children. It is important they know what to do!

WHAT TO DO WHEN THE ALARM SOUNDS

o  Leave immediately by your plan of escape. Every second counts, so don't waste time getting 

dressed or picking up valuables.

o  In leaving, don't open any inside door without first feeling its surface. If hot, or if you see smoke 

seeping through cracks, 

don't open that door!

   Instead, use your alternate exit. If inside door 

is cool, place your shoulder against it, open it slightly and be ready to slam it shut if heat and 

smoke rush in.

o  Stay close to the floor if air is smoky. Breathe shallowly through a cloth, wet if possible.

o  Once outside, go to your selected meeting place and make sure everyone is there.

o  Call the fire department from your neighbor's home – 

not from yours!

o  Don't return to your home until fire officials say that it is all right to do so.

Page 8

Summary of Contents for UNIVERSAL 2995CN

Page 1: ...urself Table of Contents Page Smoke Alarm Limitations and Functions 2 Recommended Location of Alarms 3 Avoid These Locations 4 Early Warning 4 Installation Instructions 4 Electrical Shock Hazard 4 Loc...

Page 2: ...LOADED ELECTRICAL CIRCUITS CHILDREN PLAYING WITH MATCHES NATURAL CAUSES SUCH AS LIGHTNING OR ARSON FIRE PREVENTION IS YOUR BEST SAFEGUARD l INSTALLING SMOKE ALARMS MAY MAKE YOU ELIGIBLE FOR LOWER INSU...

Page 3: ...r than 1 ft in 8 ft 1 m in 8 m horizontally shall be located within 36 in 914 mm of the high side of the ceiling but not closer than 4 in 102 mm from the adjoining wall surface Tray Shaped Ceilings Sm...

Page 4: ...all at least 3 feet 0 9 meters away from these areas in areas of turbulent air such as air returns or heating and cooling supply vents smoke alarms shall not be located where airflow prevents smoke fr...

Page 5: ...5CN therefore a natural gas alarm will NOT trigger the alarm of non natural gas sensing models within an interconnected system The following alarms cannot reset units on an interconnected system USI 7...

Page 6: ...andard household wire 18 gauge or larger rated at least 300V as required by local codes available at all electrical supply hardware stores The wiring to be used shall be in accordance with the provisi...

Page 7: ...will not normally set off the alarm unless smoke is blown directly into the smoke alarm Combustion particles from cooking may set off the alarm if the smoke alarm is located close to the kitchen cooki...

Page 8: ...CTICE A PLAN OF ESCAPE BASICS OF ESCAPE PLAN o Make a floor plan indicating all doors and windows and at least two escape routes from each room Second story windows may need a rope or chain ladder o H...

Page 9: ...ied please take all precautions if an alarm sounds by calling an Emergency Service and getting out of the home Blinks On once approx every 40 45 seconds normal operation mode or Blinks On once approx...

Page 10: ...T AND SPECIFICALLY DISCLAIMS ANY WARRANTY WHETHER EXPRESS OR IMPLIED OF FITNESS FOR A PARTICULAR PURPOSE OTHER THAN THE WARRANTY CONTAINED HEREIN NO IMPLIED WARRANTY ON THIS PRODUCT CREATED BY STATE L...

Reviews: