NEVER use an open flame of any kind to test this smoke alarm. You might accidentally 

damage or set fire to the smoke alarm or to your home. The built-in test switch accurately 

tests the smoke alarm's operation as required by Underwriters Laboratories Inc. (UL).
(UTHA) Sensitivity Indicating Means.

TESTING:

 Test by pressing the Test button on the smoke alarm cover until the alarm sounds, 

then release. The alarm sounds if all electronic circuitry, horn and battery are working. If no alarm 

sounds, the alarm may have a power supply failure. 

Test the smoke alarm weekly to assure 

proper operation. IMPORTANT: 

Under normal conditions, the test button should sound the alarm 

immediately after it is pressed. There are special conditions that, when you press the Test button, 

you will experience a delay of approx. 10-15 seconds before the alarm sounds. This delay occurs 

if the test button is pressed during a self-diagnostic period. This occurs: (1) Upon initial power 

up; (2) After battery activation (and no AC power is present); (3) If 120 volt  AC power has been 

interrupted and no backup battery is present.

ALARM ORIGINATION:

 QUICK FIND

®

 Alarm Origination - In an interconnected system consisting 

of any of these models: 5304, 5304L, MI106, MDS107, MCN108, MICN109, MDSCN111, MP117, 

MI106S and MIC1509S, it may be difficult to determine which alarm initiated the alarms to sound 
during an alarm event. This QUICK FIND

®

 feature will immediately allow you to locate the originating 

alarm once the alarms have stopped sounding. To initiate QUICK FIND

®

press the Test/Silence 

button on any alarm. After releasing the button, the test sequence on this alarm will begin and 

last 5-20 seconds, and then stop. The specific test sequence horn pattern is designated by the 

alarm type. Once this test sequence ends, the originating alarm continues to sound for approx. 

60 seconds, which provides ample time to locate the originating alarm. Remember to reset the 
originating alarm in order to clear the QUICK FIND

®

 alarm origination and to return your system to 

normal operation. Refer to the wiring instructions model interconnect compatibility section of this 

manual (Page 5) for additional information. In a non-interconnected installation, it is necessary to 

test each alarm by pressing and releasing the Test/Silence button to determine the originating alarm.

RESET:

 

To reset the QUICK FIND

®

 Alarm Origination condition, press and hold the Test 

button on any alarm for at least 10-15 seconds and then release. Reset after each alarm. 

The reset feature will reset all interconnected units.

END-OF-SERVICE LIFE NOTIFICATION:

 A majority of home fire deaths are a result of no smoke 

alarms or no 

working

 smoke alarms. In addition to the "replace by date" stamped on the back of 

your alarm, your alarm contains a unique audible end-of-service life notification feature. When it 

is time to replace your alarm, which is after approximately 10 years of operation from initial power 

up, the alarm will sound 2 chirps approx. every 60 seconds and the red LED will blink on once 

approx. every 2 minutes. The green LED stays on. The alarm should be replaced immediately.

IMPORTANT CONSIDERATIONS

YOUR ALARM HAS BEEN DESIGNED WITH A PRODUCT END-OF-SERVICE LIFE WARNING 

WHICH WILL SOUND AFTER APPROXIMATELY 10 YEARS OF OPERATION FROM INITIAL 

POWER UP.
NOTE:    MANUFACTURER  RECOMMENDS  REPLACEMENT  OF  THIS ALARM  10 YEARS 

AFTER DATE OF INSTALLATION. NOTE: NUMEROUS ALARMS OR PROLONGED ALARMING 

IS NOT TYPICAL AND WILL CONSUME THE BATTERY CAPACITY, SHORTENING THE LIFE 

OF THIS PRODUCT.

(UTHA) Sensitivity Indicating Means

The sensitivity indicating means for this Smoke and Fire Alarm is the use of the analyzer for 

Smoke Detectors Model 501-A or 501-A/Bat Aerosol Generator manufactured by Gemini Scientific 

Corp., 1122-B Aster Ave., Sunnyvale, CA 94086. The Equivalent UL 268 Light obscuration %/Ft 

as measured by this instrument must be within the obscuration listed on the back of this alarm.

(UTHA) Go/No-Go Field Test

The Go/No-Go test for this smoke and fire alarm is to use one of the following UL listed can-type 

aerosol smoke alarm testers. The instructions for use are printed on the canister. Home Safeguard, 

Model 25S.

Summary of Contents for MP116S

Page 1: ...operate maintenance testing and product features It also includes tips and information which could help protect you and your family Table of Contents Page Smoke Alarm Limitations and Functions 2 Reco...

Page 2: ...nd properties SMOKE ALARMS CANNOT DETECT FIRES IF THE SMOKE DOES NOT REACH THEM Smoke from fires may not reach the sensing chamber and set off the alarm One alarm should be installed inside each bedro...

Page 3: ...Title 24 CFR Section 3280 208 and Section 3282 For additional protection see Single Story Residence smoke alarm requirements recommendations for Existing Homes and New Construction Homes Note For mob...

Page 4: ...et Page 4 Early warning fire detection is best achieved by the installation of fire detection equipment in all rooms and areas of the household as follows A smoke alarm installed in each separate slee...

Page 5: ...terconnected system USI 7795 The following alarms can trigger Quick Find Alarm Origination but will not indicate Alarm Origination on an interconnected system USI 1103 USI 1203 USI 1204 USI 1208 Part...

Page 6: ...reen LED should be on to indicate AC power The red LED blinks on once approx every 2 minutes to indicate proper operation 120 VAC 60Hz 100mA Max OPERATION TESTING MAINTENANCE NORMAL OPERATION The alar...

Page 7: ...arm origination and to return your system to normal operation Refer to the wiring instructions model interconnect compatibility section of this manual Page 5 for additional information In a non interc...

Page 8: ...alarm DO NOT disassemble or attempt to clean inside the alarm This alarm contains no serviceable parts If the alarm becomes contaminated by excessive dirt or grease and cannot be cleaned it should be...

Page 9: ...and at least two escape routes from each room Second story windows may need a rope or chain ladder o Have a family meeting and discuss your escape plan showing everyone what to do in case of fire o D...

Page 10: ...On If alarm sounds and hazard is identified please take all precautions by getting out of the home immediately and then calling an Emergency Service Nuisance Alarm 3 Beeps 2 second pause Repeat Blinks...

Page 11: ...consequential or incidental loss or damage including but not limited to damages to any equipment with which this product is used Some states do not allow the exclusion or limitation of incidental or...