C O N D I T I O N

Non-originating smoke

 alarm. Another 

interconnected smoke 

alarm has sensed smoke 

causing all interconnected 

alarms to sound.

Non-originating CO alarm. 

Another 

interconnected CO 

alarm has sensed CO

causing all interconnected 

alarms to sound.

CO  alarm when cause of alarm 

is known and poses no threat

ALARM AUDIBLE & VISUAL SIGNALS

HORN

3 Beeps, 

2 second 

pause, repeat

4 Beeps, 

5 second 

pause, repeat

4 Beeps, 5 

second pause, 

repeat

PWR 

GREEN 

LED

Stays on

Stays on

Stays on

SMK RED 

LED

Off

Blinks on 

approx. every 

2 minutes

Blinks on 

approx. every 

2 minutes

CO RED 

LED

Off

Off

Blinks On in 

sync with the 

4 beeps

RECOMMENDATION

Another interconnected smoke alarm has 

sensed smoke causing all interconnected 

alarms to sound. If hazard is identified please 

take all precautions if an alarm sounds by 

calling Emergency Service and getting out 

of the home. 

Originating CO alarm

4 Beeps, 

5 second 

pause, repeat

Stays on

Blinks on 

approx. every 

2 minutes

Blinks On in 

sync with the 

4 beeps

If hazard is identified please take all precau-

tions if an alarm sounds by calling an Emer-

gency Service and getting out of the home. 

Nuisance alarm

Horn sounds 

when no hazard 

present

Stays on

Blinks On in 

sync with the 

3 beeps

Blinks On in 

sync with the 

4 beeps

If there is no hazard present verify the alarm 

is mounted in the correct location (see user’s 

manual). Reset alarm as instructed below.

 Smoke alarm when cause 

of alarm is known and poses 

no threat

3 Beeps, 

2 second 

pause, repeat

Stays on

Blinks On in 

sync with the 

3 beeps

Off

The smoke alarm Silence Feature can be 

activated by pressing and releasing the Silence 

button on the initiating alarm while in alarm 

condition. Silence mode will last for approx-

imately 8 - 12 minutes [With the red LED 

blinking on approx every 10 seconds].

Alarm needing reset due to 

abnormal operation/previous 

alarms

Silent (alarmed 

previously)

Stays on

Blinks on 

approx. every 

2 minutes

Off

To reset the alarm, hold the 

Test button for 10-15 seconds.                                                           

This will clear alarm origination. Reset  

after each alarm event.

Low Battery or Product End-of-

Service Life Warning

2 Chirps approx 

every 60 

seconds

Stays on

Blinks on 

approx. every 

2 minutes

Off

Deactivate alarm (See User’s Manual 

“ALARM DEACTIVATION” section).                                                            

The warning cannot be silenced.  Replace 

alarm immediately. 

Sensor Trouble Signal

RESET INSTRUCTIONS:

 Press the Test/Silence button for 10-15 seconds and then release. This will clear the alarm origination and latching LED.  

Be sure to RESET alarms after every alarm event. 

QUICK FIND

® Alarm Origination/Location Feature: The QUICK FIND® feature will allow you to immediately locate the originating alarm (the alarm 

that triggered the other alarms), once the alarms have stopped sounding.
1. Press and release the Test button on any alarm. After releasing the button, the test sequence on this alarm will begin, and last approximately  

    5-20 seconds.  
2. Once this test sequence ends, the originating alarm continues to sound for approximately 60 seconds, which provides ample time to locate the 

    originating alarm.  
3. Remember to reset the originating alarm in order to clear the QUICK FIND® and return the system to normal operation.  

NOTE:

 If you have any additional questions about the operation of Model MIC1509S, please contact our Customer Service Department at  

800-390-4321, and we will gladly assist you. 

3 Chirps approx 

every 60 

seconds

Stays on

Blinks on 

approx. every 

2 minutes

Off

Reset the alarm. If this does not clear the 

trouble signal, replace alarm immediately.  

The sensor trouble signal cannot be silenced.

Previous alarm condition at 

unidentified source

Silent (alarmed 

previously)

Stays on

Blinks on 

approx. every 

2 minutes

Off

Quick Find® Alarm Origination - In an intercon-

nected system it is difficult to determine which 

alarm initiated the alarms to sound. The Quick 

Find® feature will allow you to immediately 

locate the originating alarm (once the alarms 

have stopped sounding). To initiate Quick 

Find® press the Test button on any alarm. 

After releasing the button and following the test 

sequence, the originating alarm will continue 

to sound for approximately 60 seconds. In a 

non-interconnected installation, it is necessary 

to test each alarm to determine the originating 

alarm.

An interconnected CO alarm has sensed CO 

causing all interconnected alarms to sound. If 

hazard is identified please take all precautions 

if an alarm sounds by calling  Emergency 

Service and getting out of the home. 

The CO alarm Silence Feature can be 

activated by pressing and releasing the Silence 

button on the initiating alarm while in alarm 

condition. The alarm will remain silent for ap-

prox 5 minutes [With the red LED blinking on 

approx every 10 seconds], depending on the 

level of CO detected. If CO levels drop below 

alarm levels, the alarm will remain silent and 

return to normal operation. If CO levels remain 

constant or increase, this indicates a potentially 

dangerous situation and the horn will sound 

again. Ventilate area.

288-3564-01

QUICK REFERENCE GUIDE - Model MIC1509S

USI Electric, Inc. 

1-800-390-4321