background image

Page 16

C O N D I T I O N

New -  Out of package.

AC power is present.

DC power is present.

 The Test button has been 

pressed. The test sequence 

lasts for approx 10 seconds

One or more alarms not

 responding to 

interconnected alarm.

ALARM AUDIBLE & VISUAL SIGNALS

HORN

Off

Silent

3 Beeps, 

6 second 

pause, 

4 beeps.

Horn does 

not sound 

when other 

alarms are 

active or when 

test button is 

pressed on 

interconnected 

alarm

PWR 

GREEN 

LED

Off

Stays On

Stays On

Stays On

SMK RED 

LED

Off

Blinks On 

approx. every 

2 minutes.

Blinks On in 

sync with 3 

beeps.

Blinks on 

approx. every 

2 minutes

CO RED 

LED

Off

Off

Blinks On in 

sync with  4 

beeps.

Off

RECOMMENDATION

To activate the alarm remove the pull tab.  The 

alarm will sound one long beep to let you know 

it is powered up. 

Alarm is operating properly.

Alarm is powered 

by battery backup. 

AC power not present. 

Silent

Off

Blinks On 

approx. every 

2 minutes.

Off

Check the breaker or fuse box for power.  If 

the breaker or fuse box looks normal, call a 

licensed electrician for assistance.

Test the alarm following installation and weekly 

thereafter. The built-in test switch accurately 

tests the alarm operation as required by ANSI/

UL217 and UL2034 Standards for Safety. If, 

at any time, the alarm does not perform as de-

scribed during the test, replace it immediately.

Press and hold the smoke alarm Test button 

for at least 5 seconds. If still no alarm, turn off 

AC Power at the circuit breaker or fuse box 

and disconnect the alarm from the mounting 

bracket and make sure the connector plug 

is securely attached on alarms that did 

not sound. If still no alarm, have licensed 

electrician make sure the yellow wire is not 

mistakenly or accidentally connected to the 

white (neutral) wire. NOTE: In an intercon-

nected system containing a CO alarm, the 

CO alarm will not respond to the smoke alarm 

signal and the smoke alarm will not respond to 

the CO alarm signal.

Originating Smoke Alarm

3 Beeps, 2 

second pause, 

repeat

Stays On

Blinks on in 

sync with 3 

beeps 

Off

If hazard is identified please take all precau-

tions if an alarm sounds by calling an Emer-

gency Service and getting out of the home. 

 The Test button has been 

pressed. The test sequence 

lasts for approx 10 seconds.

3 Beeps, 

6 second 

pause, 4 

beeps.

Stays On

Blinks On in 

sync with 3 

beeps.

Blinks On in 

sync with  4 

beeps.

Test the alarm following installation and weekly 

thereafter. The built-in test switch accurately 

tests the alarm operation as required by ANSI/

UL217 and UL2034 Standards for Safety. If, 

at any time, the alarm does not perform as de-

scribed during the test, replace it immediately.

Originating Smoke Alarm 

3 Beeps, 2 

second pause, 

repeat

Stays On

Blinks on in 

sync with 3 

beeps 

Off

If hazard is identified please take all precau-

tions if an alarm sounds by calling an Emer-

gency Service and getting out of the home. 

One or more alarms not

 responding to 

interconnected alarm.

Horn does 

not sound 

when other 

alarms are 

active or when 

test button is 

pressed on 

interconnected 

alarm

Stays On

Blinks on 

approx. every 

2 minutes

Off

Press and hold the smoke alarm Test button 

for at least 5 seconds. If still no alarm, turn off 

AC Power at the circuit breaker or fuse box 

and disconnect the alarm from the mounting 

bracket and make sure the connector plug 

is securely attached on alarms that did 

not sound. If still no alarm, have licensed 

electrician make sure the yellow wire is not 

mistakenly or accidentally connected to the 

white (neutral) wire. NOTE: In an intercon-

nected system containing a CO alarm, the 

CO alarm will not respond to the smoke alarm 

signal and the smoke alarm will not respond to 

the CO alarm signal.

THIS PRODUCT IS LISTED TO UL STANDARD FOR SAFETY, UL 217 and UL 2034

QUICK REFERENCE GUIDE - Model MIC1509S