THIS PRODUCT CONFORMS TO UL 217 STANDARD FOR SAFETY

BY UNDERWRITERS LABORATORIES, INC.

Silent

Off

OPERATIONAL SUMMARY

Blinks On

 in sync

with horn

3 Beeps,

2 second pause,

Repeat

RECOMMENDATION

HORN

RED LED

GREEN LED

New - Out of Package

To activate the alarm, remove the pull tab. The 
alarm will sound one long beep to confirm it is 
powered up. Press the Test/Silence/Reset/Peak 
button. Test the alarm following installation and 
weekly thereafter. The built-in test switch accurately 
tests the alarm operation as required by ANSI/
UL217 Standards for Safety Standards for Safety. 
If, at any time, you test the alarm and it does not 
perform as described, replace it immediately.

CONDITION

RECOMMENDATION

Off

Blinks On once

approx every

2 minutes

AC Power is present
DC Power is present

ALARM AUDIBLE & VISUAL SIGNALS

Silent

Stays On

Alarm is operating properly.

Blinks On once

approx every

2 minutes

AC Power is not present

DC Power is present

Silent

Off

Check the breaker or fuse box for power. If the 
breaker or fuse box looks normal, call a licensed 
electrician for assistance.

Press and hold the smoke alarm Test/Silence 
button for at least 5 seconds. If still no alarm, 
turn off AC Power at the circuit breaker or 
fuse box and disconnect the alarm from the 
mounting bracket and make sure the connector 
plug is securely attached on units that did not 
alarm. If still no alarm, have licensed electrician 
make sure the yellow wire is not mistakenly or 
accidentally connected to the white (neutral) 
wire. NOTE: In an interconnected system 
containing a CO alarm, the CO alarm will 
not respond to the smoke alarm signal and 
the smoke alarm will not respond to the CO 
alarm signal.

Blinks On once

approx every

2 minutes

One or more alarms 

not responding to 

interconnected alarm

Horn does not

sound when other 

alarms are active

or horn does 

not sound when 

interconnected 

alarms test button

is pressed

Stays On

Originating Smoke Alarm

Stays On

If alarm sounds and hazard is identified, 
please take all precautions by getting out of 
the home immediately and then calling an 
Emergency Service. 

Non-originating 

smoke alarm. Another 

interconneced smoke

alarm has sensed smoke, 

causing all interconnected 

units to alarm. 

3 Beeps,

2 second pause,

Repeat

Off

Stays On

If alarm sounds and hazard is identified, 
please take all precautions by getting out of 
the home immediately and then calling an 
Emergency Service. 

Nuisance Alarm

3 Beeps,

2 second pause,

Repeat

Blinks On in

sync with horn

Stays On

If there is no hazard present and the unit is 
still sounding, activate the silence feature by 
pressing and releasing the Test/Silence button 
on the initiating alarm. Silence mode will last for 
approx 10 minutes, with the red LED blinking 
once approx every 10 seconds. Verify the 
alarm is mounted in the correct location (see 
User's Manual, "AVOID THESE LOCATIONS" 
section). Reset alarm as instructed below.

One alarm has sensed 

smoke and is

now silent.

Silent

Blinks On once 

approx every

2 minutes

(normal

operation mode)

or Blinks On
once approx

 every 10 seconds

(silence mode)

Stays On

QUICK FIND

®

 Alarm Origination - In an 

interconnected system, it is difficult to determine 
which alarm initiated the alarms to sound. The 
QUICK FIND

®

 feature will immediately allow 

you to locate the originating alarm (once the 
alarms have stopped sounding). To initiate 
QUICK FIND

®

, press and hold the test/silence 

button on any alarm until the test sequence on 
this alarm begins. Release the test button. The 
specific  horn  pattern/sequence  is  designated 
by the alarm type.  Once this test sequence 
ends, the originating alarm continues to sound 
for approximately 60 seconds. In a non-
interconnected installation, it is necessary to 
test each alarm to determine the originating 
alarm. Reset alarm as instructed below.

Alarm needs to be reset

due to varying

conditions/previous

alarms

Stays On

Silent

To   R e s e t   t h e   A l a r m ,   p r e s s   t h e 

 

Test/Silence button for approx 10 seconds. This 
will clear Alarm Origination. Reset after each 
smoke alarm event.

Low Battery

2 Chirps approx 

every 60 seconds

Blinks On once 

approx every 2 

minutes

Stays On

Deactivate alarm (see User's Manual "ALARM 
DEACTIVATION" section. Replace alarm 
immediately.

Product End-of-Service

Life signal

2 Chirps approx 

every 60 seconds

Blinks On once 

approx every 2 

minutes

Stays On

Deactivate alarm (see User's Manual "ALARM 
DEACTIVATION" section. Replace alarm 
immediately.

Blinks On once 

approx every

2 minutes

(normal operation 

mode)

or Blinks On
once approx

 every 10 seconds

(silence mode)

Summary of Contents for MI106S

Page 1: ...ears This manual includes important information regarding where to install the alarm how to operate maintenance testing and product features It also includes tips and information which could help prot...

Page 2: ...their lives and properties SMOKE ALARMS CANNOT DETECT FIRES IF THE SMOKE DOES NOT REACH THEM Smoke from fires may not reach the sensing chamber and set off the alarm One alarm should be installed ins...

Page 3: ...Home Installation For minimum protection smoke alarms should be installed in compliance with H U D Manufactured Home Construction Safety Standards Title 24 CFR Section 3280 208 and Section 3282 For ad...

Page 4: ...et Page 4 Early warning fire detection is best achieved by the installation of fire detection equipment in all rooms and areas of the household as follows A smoke alarm installed in each separate slee...

Page 5: ...hrough an interconnected system because they do not have Quick Find Alarm Origination USI 1103 USI 1204 USI 1208 USI 1209 USI 5204 USI 3204 USI 2430 USI 7795 Interconnected smoke alarms heat alarms an...

Page 6: ...ating once the AC power is connected the battery pull tab has been removed and the alarm has sounded one long beep The green LED is on the red LED blinks on once approximately every two minutes The ho...

Page 7: ...alarm origination and to return your system to normal operation Refer to the wiring instructions model interconnect compatibility section of this manual Page 5 for additional information In a non inte...

Page 8: ...attempt to clean inside the alarm This alarm contains no serviceable parts If the alarm becomes contaminated by excessive dirt or grease and cannot be cleaned it should be replaced immediately Alarms...

Page 9: ...g methods in accordance with the National Fire Protection Association s Standard 72 National Fire Protection Association Batterymarch Park Quincy MA 02269 DEVELOP AND PRACTICE A PLAN OF ESCAPE BASICS...

Page 10: ...d smoke causing all interconnected units to alarm 3 Beeps 2 second pause Repeat Off Stays On If alarm sounds and hazard is identified please take all precautions by getting out of the home immediately...

Page 11: ...arranty contact the Customer Service Department at 800 390 4321 extension 238 to obtain the current postage and handling fees USI does not warrant and specifically disclaims any warranty whether expre...