Intended Use 

03/19

Fl Detect Set

Intended Use 

Please observe the notes in this operating manual as well as the 
operating conditions and permissible data in the data sheet so that 
the system functions perfectly and remains operational for a long 
time. In case of non-observance of these instructions as well as in 
case of inadmissible interventions into the system, any liability on 
our part is void, as is the warranty on the system and accessories!  

 

An  external  water  sensor  can  be  connected  directly  to  the 
Fl I/O connection. In this case, however, no Fl 
Hub or further water sensor can be connected as the connection is 
already occupied. 

The  Fl  Detect  Set  contains accessories  for  splitting  the 
Fl  I/O  connector.  Thus  a  Fl  Hub  and  an 
external water sensor, or several water sensors can be connected 
in series. 

 

If  the  water  sensor  detects  conductive  drinking  water,  the 
Fl is shut off immediately. 

An  alarm  reset  can  only  be  performed  via  the  connected 
Fl or its supply voltage. 

 

Any other use or use going beyond this shall be deemed improper 
use.  The  usetech  GmbH  is  not  liable  for  damages  resulting  from 
this. The risk is borne solely by the user. 

 

 

Summary of Contents for FlowTimer+ Detect Set

Page 1: ...FlowTimer Detect Set Direct water detection with the FlowTimer system Operating Manual...

Page 2: ...rinting date 04 03 2019 Copyright usetech GmbH This documentation including all its parts is protected by copyright Any use or modification outside the narrow limits of copyright law without the conse...

Page 3: ...se 6 4 System description FlowTimer Detect Set 7 4 1 Content of the FlowTimer Detect Set 7 5 Installation 8 5 1 Mounting the FlowTimer Detect Set 8 5 2 Placement of splinters and cables 8 5 3 Electric...

Page 4: ...on observance of these instructions can lead to dangerous situations The operating instructions must be read and understood 1 1 Explanation of symbols DANGER Warns of imminent danger Failure to do so...

Page 5: ...at are important for your safety and the proper functioning of the system refers to information in this operating manual or other documentation Action steps The defined sequence of steps makes it easi...

Page 6: ...ection 10 m cable with FlowTimer I O connector 2 2 Environmental and climate conditions Splinters Ambient temperature 5 C 40 C Protection class IP20 Location Splinters I O cable and connector Only sui...

Page 7: ...d directly to the FlowTimer I O connection In this case however no FlowTimer Hub or further water sensor can be connected as the connection is already occupied The FlowTimer Detect Set contains access...

Page 8: ...er hub to connect FlowTimer devices to each other It can only be used within an I O connection between FlowTimer and FlowTimer Hub to connect water sensors The water sensor is only suitable for electr...

Page 9: ...FlowTimer Detect Set 4 1 Content of the FlowTimer Detect Set Fig 4 1 Content of the FlowTimer Detect Set 1 Water sensor with 10 m cable and I O connector 2 I O splinter with three I O connectors 3 I O...

Page 10: ...sture only please keep a small distance between sensor and floor If possible keep a small distance between the sensor and the wall in order to accelerate the drainage of water at the sensor after an a...

Page 11: ...d into the socket this must cause a clicking noise If not please check again whether the plug is correctly engaged When disconnecting connections please note to press the locking lugs of the I O conne...

Page 12: ...ure 4 1 Plug the I O connector 4 of the first set into the FlowTimer connector All further sets are then simply connected in series The I O connector 4 of the second set is plugged into the splinter o...

Page 13: ...on No service is necessary If the water sensor detects conductive drinking water the FlowTimer is shut off 6 1 2 Restarting the system An alarm reset can only be performed via the connected FlowTimer...

Page 14: ...nects without a reason being found unplug the I O connector 4 of the FlowTimer Detect Set from the I O connector of the FlowTimer Now check your FlowTimer system according to the instructions of the r...

Page 15: ...oisture and dirt and transport it in shockproof packaging Avoid exceeding or falling below the permissible storage temperature Protect electrical connections from damage with protective caps The syste...

Page 16: ...Electrical and Electronic Equipment Act ElektroG Please dispose of old equipment at a municipal collection point as required by law or hand it over to your local dealer free of charge Disposal with ho...

Page 17: ...f the use of certain hazardous substances in electrical and electronic equipment The usetech GmbH Tanzplatz 10 D 55130 Mainz declares that Product Name Flowtimer Detect Set Type V1 1 Year of construct...

Reviews: