Blutronium™ Serial Bluetooth Adapter – Datasheet & Quick Reference

 

www.USconverters.com

 

  

www.usconverters.com 

Page 9 

 

 

Inquire the current setting 

NAME= 

 

This command is used to specify a name for the adapter.  
You can specify a friendly name using 0 to 9, A to Z, a to z, space and –, which are all valid 
characters. Note that “first space or -, last space or – isn’t permitted”. The default name is 
“Serial Adapter”. 

(Default) 

Serial 
Adapter 

Default device name 

 

xx….xx 

“xx….xx” is a character string with the length from 2 to 30. 

 

Restore the default settings name=“Serial Adapter”. 

 

Inquire the name of the local adapter. 

PARITY= 

 

This command is used to specify parity bit setting of COM port. 
The command will need 200 ms delay. 

(Default) 

None parity bit 

 

Odd parity 

 

Even parity 

 

Inquire the current setting. 

PIN= 

 

This command is used to specify a PIN. The default PIN is “1234”. Paired adapters should 
have a same PIN. The length must be 4 – 16 alphanumeric characters.  
Notice: this function currently only works with Windows versions prior to Windows 8.1 

(Default) 

1234 

 

 

xx….xx 

“xx….xx” is a

 

4 - 16 digit string of alphanumeric characters (in capital or lower case) 

 

Cancel authentication by PIN. 

 

Restore the default settings PIN=“1234”. 

 

Inquire the current PIN. 

PROMPT= 

 

This command is used to decide whether status messages are prompted when Setup 
commands are executed. The status messages are: OK/ERROR for command execution, or 
CONNECT/DISCONNECT/Try Connect Device for connection status. 

(Default) 

Prompt result messages. 

 

Not prompt result messages. 

 

Inquire the current setting. 

RECONNEC
T= 

 

The command is used to re-connect the lost link for the Master adapter. 

 

Inquire the current setting. 

(Default) 

Re-connect is disable 

 

Re-connect is Enable 

ROLE= 

 

This command is used to specify whether the adapter is in the master or slave mode. If the 
device mode is changed, the adapter will reboot and all paired addresses will be cleared. The 
command is available when the adapter is in DIP=N status. The command will need 1 second 
delay. 

 

Set the adapter to the master mode. 

(Default) 

Set the adapter to the slave mode. 

 

Inquire the current mode of the adapter. 

RSSI= 

 

Received signal strength indication

 

Display the Received signal strength indication in command mode when connected.  
1.  Strong: RSSI>-9 
2.  Medium: -9>RSSI>-20 
3.  Weak: RSSI<-20 

SEARCH= 

 

This command is used to search for any Bluetooth device in the neighborhood within one 

Summary of Contents for Blutronium B-TRON 5000

Page 1: ...red over Bluetooth Internal rechargeable lithium battery Baud rates from 1200 to 921 600bps Basic configuration by DIP switches Communication range up to 300 feet Works with most mobile devices USB po...

Page 2: ...ffer size 4Kb Operating distance Up to 330 feet 100 meters in open space LED lights Power Batt Status TX RX and Charging Bluetooth stack Serial Port Profile SPP PIN PIN code available for pairing Conn...

Page 3: ...e Reverse Polarity SMA male inside threads center receptacle Antenna connector on adapter Reverse Polarity SMA female outside threads center pin Power options Mini USB cable 5VDC DB9 connector Pin 9 4...

Page 4: ...ent the adapter is turned ON Position S W The adapter is using the parameters set by software by default the PROMPT AND ECHO parameters are enabled in this position Run Config Position Run The adapter...

Page 5: ...r pin 9 Status LED off No pairing Status LED fast 0 1 sec blinking Pairing slave or master mode Status LED fast 0 3 sec blinking Discoverable and waiting for a connection slave mode Status LED slow 0...

Page 6: ...tion The parameters can be configured over Bluetooth or through the adapter s serial port by using the Blutronium Configuration Utility which can be downloaded from https www usconverters com activate...

Page 7: ...This command is used to enable disable the auto connection feature It is available only when the adapter is in Master mode and only when DIP N The system will not re start after changing this paramete...

Page 8: ...to mode xxxxxxxxx xxx xxxxxxxxxxxx is a string of 12 hexadecimal digits R Restore the status in which the adapter can connect with any remote address Inquiry the designated address that can be paired...

Page 9: ...racters in capital or lower case N Cancel authentication by PIN R Restore the default settings PIN 1234 Inquire the current PIN PROMPT This command is used to decide whether status messages are prompt...

Page 10: ...ware version Inquire the version codes Some commands are unavailable under certain conditions If this command is set to These commands are unavailable ROLE S SEARCH CONNECT CONNECT P CONNECT xxxxxxxxx...

Page 11: ...on reception which can be determined by turning the equipment off and on the user is encouraged to try correcting the interference by one or more of the following measures Reorient the receiving anten...

Reviews: