TROUBLESHOOTING - AT500H AUTO TREATER 

Below is a table describing the most frequent problems and solutions with the USC 
AT500H Treater .  For further assistance, contact the USC Service department at      
(785) 431-7900. 

Problem 

Possible Cause 

Solution 

Seed Gate Actuator will not 
move. 

1.  Adjustable Chamber   

mechanism jammed with  
debris. 

2.  One or both of the two     

connectors linking the      
actuator to the control panel 
are not connected. 

1.   Clear all debris and make 

sure mechanism moves 
freely. 

2.  Make sure both connectors 

are properly engaged. 

Seed Gate Actuator will not    
return to the closed position   
after all seed has emptied      
from the box. 

1.  Proximity switch is dirty. 
2.  Proximity switch is set too 

sensitive. 

3.  The system is running in 

HAND mode. 

1.   Clean proximity switch. 
2.  Adjust the pump proximity 

switch sensitivity              
(see page 4). 

3.  Change to AUTO mode. 

Seed Gate Actuator will not move 
in AUTO. 

1.  Proximity switch is not     

staying covered. 

2.  Proximity switch is not set      

sensitive enough. 

3.  HMI screen not set to AUTO. 
 

1.   Make sure proximity switch is 

staying covered with seed. 

2.  Adjust pump proximity switch 

sensitivity by turning the   
adjustment screw clockwise. 

3.  Set HMI screen to AUTO. 

Seed Gate Actuator will not close           
completely. 

1.  Debris may be keeping it 

from closing completely. 

 

1.   Open the seed gate, remove  

debris and power cycle the 
entire system.  When the 
system is turned back on, the 
gate will automatically close 
and find it’s Home position. 

Auger overload keeps tripping 

1.  Seed flow is too high. 
2.  Too much liquid being      

applied. 

1.    Slow down seed flow. 
2.    Lower the liquid rate. 