background image

CAUTION:

 

PLEASE FOLLOW THIS INSTRUCTION MANUAL CAREFULLY TO

PREVENT ANY INJURIES OR COMPLICATIONS THAT MAY ARISE.

WARNING: 

Before installing or maintaining the luminary, make sure all powers are

TURNED OFF

.

Verify that supply voltage is correct by comparing it with the label information on all
fixtures.
Make all connections in accordance with the NEC requirements, and make sure all
luminaries are properly secured to prevent any wire complications. This luminary is
to always be installed with the lens facing down and its not to exceed the maximum
ambient temperature rating noted on the specification sheet.

USSLxxxWPL

 Series LED Area Light 

Installation Sheet

LED DRIVER

V(-)

[BLACK]

V(+)

[RED]

TO LOAD

[LED BOARD]

[WHITE]

[BLACK]

ACN [BLUE/WHITE]

ACL [BROWN/BLACK]

GROUND [GREEN]

NEUTRAL [WHITE]

GROUND [GREEN]

HOT [BLACK]

INPUT

OUTPUT

DIM

WHITE (-)

BL

UE(+)

Inside F2SB

PRE-CONNECTED

(DO NOT DISCONNECT)

Using a J-Box (not included), Connect the ACL and the ACN from the driver to the conduit with the AC Power Supply cords.Follow the Wiring Diagram provided.

* LED DRIVER Input Ground (green) wire only available for selected fixtures.

If the Ground Wire is missing and the Power Supply includes a ground wire, connect the power supply ground wire to the fixture.

(FOR DIMMABLE VERSION)

ARM MOUNT (SQUARE POLE)

 

7. Adjust the Tilt  Angle on the

 

luminaire, 

once the Tilt Angle is as

 

desired, finish 

tightening the Socket

 

Head bolt to firmly  

tighten the 

fixture 

with

 

the Arm Mount.

STANDARD INSTALLATION STEPS

DRILLING TEMPLATE

5.50 in

4.25 in

3.6875 in

.625 in

1.

 Use provided Hole Pattern for drilling. Make sure to make

 

an extra notch for the power cables to run through the 

Square 

Tube.

2.

 Place mount against 

square

 tube.

3.

 Install the provided [2] Socket head

M8-1.25 x 40 mm bolts with lock washer
and washer to secure the arm mount
firmly in place, insert the flat-bar
with threaded holes inside the
round tube and use the
threaded holes to secure
the mount. Make sure all
bolts are tightened and
holes are properly sealed.  

4. Once the Arm Mount is properly

 

fastened to the mounting round pole, run

 

the  power cord cable from the inside of

 

the  pole and out the notch from the 
Arm Mount. This cable
will then be inserted into
the fixture.

5.

 Run the power cord from the

 

arm 

mount to the luminaire,

 

Once the 

cable has been inserted

 

inside the 

fixture

, connect the power

 

cable to 

the LED Driver inside the

 fixture

. In 

order to access the LED

 

Driver 

cables, the electrician must

 

first 

remove the [6] screws from the 
service door using a #2 Phillips

 

screw driver and make all

 

connections inside the luminaire.

6.

 Once all wiring is complete,

 

Close the service door and use

 

the 

M12 bolt to fasten the
Arm Mount to the

 fixture

.

Do not fasten completely. 

Summary of Contents for USS WPL Series

Page 1: ...SION ARM MOUNT SQUARE POLE 7 Adjust the Tilt Angle on the luminaire once the Tilt Angle is as desired finish tightening the Socket Head bolt to firmly tighten the fixture with the Arm Mount STANDARD INSTALLATION STEPS DRILLING TEMPLATE 5 50 in 4 25 in 3 6875 in 625 in 1 Use provided Hole Pattern for drilling Make sure to make an extra notch for the power cables to run through the Square Tube 2 Place...

Page 2: ...agram provided LED DRIVER Input Ground green wire only available for selected fixtures If the Ground Wire is missing and the Power Supply includes a ground wire connect the power supply ground wire to the fixture FOR DIMMABLE VERSION 3 6875 in 625 in 2 Place mount against round tube 3 Install the provided 2 Socket head M8 1 25 x 40 mm bolts with lock washer and washer to secure the Mount firmly in pl...

Page 3: ...he Power Supply includes a ground wire connect the power supply ground wire to the fixture FOR DIMMABLE VERSION 1 Use provided dimensins for determining if the Slipfitter Mount can be used In this installation example the round pole is smaller than 2 5 diameter 2 Place mount over the round pole 3 Install the provided 6 Socket head M8 1 25 x 20 mm bolts to secure the Slipfitter Mount firmly in place Ma...

Page 4: ...ening the Socket Head bolt to firmly tighten the F2SB with the Trunnion Mount LED DRIVER V BLACK V RED TO LOAD LED BOARD WHITE BLACK ACN BLUE WHITE ACL BROWN BLACK GROUND GREEN NEUTRAL WHITE GROUND GREEN HOT BLACK INPUT OUTPUT DIM WHITE BLUE Inside F2SB PRE CONNECTED DO NOT DISCONNECT Using a J Box not included Connect the ACL and the ACN from the driver to the conduit with the AC Power Supply cord...

Page 5: ... Protector VMAX AC 480v maximum Lighting Surge Current 20 000A This installation guide is for either the AC2SBSU or the AC2SBSU480 Not both 1 2 Remove the 4 screws that hold the LED driver in place in order to be able to move the driver a little off to the side to make room for the surge protector 3 Follow the Wiring Diagram provided to install the Surge Protector This must be performed by a qualifi...

Page 6: ...re this part is inserted and twist locked into place This installation is for one of the two photocells noted 1 10 00066 Flathead Machine Screw are used to fasten the AC2SBPS BASE on top of the luminaire 2 1 Using a Phillips Screw Driver remove the 4 Flathead machine screws that hold the cap in place and remove the cap and the gasket 2 A qualified electrician is required to perform the electrical w...

Reviews: