Manual Programming
In the manual programming mode, the user can set 8 cap codes, the baud rate, and the
pager frequency without connecting to a computer.
To enter the manual programming mode, while inserting the battery, depress and
hold the large ENT key for 2 seconds. If the Hand Programming feature and
password protection have been enabled, the Password screen should appear.
If the Hand Programming feature is not enabled, this screen will not appear. If the
password protection option is not enabled, the Main Menu screen should be the first to
appear.
Enter the password by pressing the Right key to increment the value of the first digit, Left
key to decrement. Press the ENT key to shift to the next digit. When the 4 digit display
corresponds to the stored password programmed from the CCP, press the ENT key to
display the Main Menu screen. If incorrect numbers were input, the pager will immediately
turn off.
Default password is “0200”.
The Main Menu screen displays cap code addresses appearing in order from 1 to 8, the
Baud Rate and current setting, the pager Frequency and current setting, and a line for
Programming. Pressing the Right key will increment to the next line, Left key will
decrement to the previous line.
To program a cap code address, use the Right and Left keys to highlight the address.
Press the ENT key to select that address.