7
to enter into the menu setting interface, setting parameters from F2~F5. Below
shows where the
CAL
button is.
4.2 Detailed parameter setting
F1 Scale parameter setting
F1.1 Capacity
Selectable parameters 3~200000 (default 6)
F1.2 Decimal
Selectable parameters: 0-------no decimal
1------ 1 decimal
2-------2 decimals
3-------3 decimals (default)
4-------4 decimals
F1.3 Division
Selectable parameters: 1(default), 2, 5, 10, 20, 50
Note: when F1.2, F1.3 or F1.4 is being set, division value should not be beyond 10000.
F1.4 Zero calibration
remove weights off the scale and make sure there is nothing on the scale.
Press
PRINT and the screen shows
which decreases to
.
Finally,
appears for one second indicating zero calibration finishes.
F1.5 Load Calibration
add weights
Add weights to the scale and make sure: scale capacity *50% ≤ weights ≤ scale capacity.
Press PRINT to enter into the next step.
Enter the same weight value as
the weights. When the scale is stable, press
PRINT and the indicator shows
which decreases to
. Finally,
appears for one