USA Measurements US-1011 User Manual Download Page 8

 

PRINT

to enter into the menu setting interface, setting parameters from F2~F5. Below 

shows where the 

CAL

  button is. 

 

 

 

 

 

 

4.2 Detailed parameter setting 

F1 Scale parameter setting 

F1.1 Capacity 

Selectable parameters 3~200000 (default 6) 

F1.2 Decimal 

Selectable parameters: 0-------no decimal 

            1------ 1 decimal 

2-------2 decimals 

3-------3 decimals (default) 

4-------4 decimals 

F1.3 Division   

Selectable parameters: 1(default), 2, 5, 10, 20, 50 

Note: when F1.2, F1.3 or F1.4 is being set, division value should not be beyond 10000. 

F1.4 Zero calibration 

  remove weights off the scale and make sure there is nothing on the scale. 

Press 

PRINT   and the screen shows

which decreases to 

Finally, 

appears for one second indicating zero calibration finishes. 

F1.5 Load Calibration 

add weights 

Add weights to the scale and make sure: scale capacity *50% ≤ weights ≤ scale capacity. 

Press PRINT to enter into the next step. 

  Enter the same weight value as 

the  weights.  When  the  scale  is  stable,  press 

PRINT   and  the  indicator  shows

  which decreases to 

. Finally, 

  appears for one 

Summary of Contents for US-1011

Page 1: ...USA Measurements US 1011 Indicator User Manual R1 1 ____________________________________________________________________...

Page 2: ...BOOKMARK NOT DEFINED 2 2 RS232 PORT ERROR BOOKMARK NOT DEFINED 2 3 LOA D CELL PORT ERROR BOOKMARK NOT DEFINED 3 0 OPERATION 4 3 1 INDICATING LAMPS 4 3 2 OPTIONAL BUTTIONS ERROR BOOKMARK NOT DEFINED 4...

Page 3: ...MULATION FUNCTION 10 5 3 COUNTING FUNCTION 10 APPENDIX 1 INDICATOR PROMPT MESSAGE ERROR BOOKMARK NOT DEFINED APPENDIX 2 SERIAL PORT OUTPUT FORMAT 13 APPENDIX 3 PRINTING OUTPUT FORMAT ERROR BOOKMARK NO...

Page 4: ...at full scale 1 10 mV Inner resolution 1 million Display division 1000 30000 A D sampling rate 120times sec Power supply mode Battery 7 4V 4AH lithium battery Adaptor input voltage 100 240 VAC output...

Page 5: ...FACE 2 1 Power supply 1Pin inner core DC 2Pin outer coreA DC 2Pin TXD 3Pin RXD 5Pin GND 2 1Pin E 2Pin SN 5Pin SHLD 6Pin E 7Pin SN 8Pin S 9Pin S 3 0 Operation 3 1 indicating lamps sign Analysis Remark...

Page 6: ...in use accumulation The lamp is on when the accumulation function is in use Weight unit The weight unit in use Battery power The power is too low and charge the battery in time Button indicator This s...

Page 7: ...oss weight Move cursor to the right TARE Skin removal gross weight net weight Decrease number ZERO Zeroing Increases number PRINT Short press start up when the indicator is off Long press shut down wh...

Page 8: ...te when F1 2 F1 3 or F1 4 is being set division value should not be beyond 10000 F1 4 Zero calibration remove weights off the scale and make sure there is nothing on the scale Press PRINT and the scre...

Page 9: ...able parameters 0 sorting default 1 accumulation 2 counting F1 11 Restoring factory default Selectable parameters 0 no restore 1 restore parameters from F1 F4 while scale parameters will not be affect...

Page 10: ...is ineffective F4 Serial port communication F4 1 Communication method Selectable parameters 0 no output default 1 continuous output only when the indicator is at stable state 2 printing output format...

Page 11: ...Suppose the current weight is Wt the empty scale range is Ewt the sorting lower limit is Lwt the sorting upper limit is Swt Make sure Swt Lwt Ewt and then Wt Ewt off Wt Lwt on Lwt Wt Swt on Wt Swt on...

Page 12: ...in general situation Once an error occurs please make clear the error first and observe whether the instrument still has error after power on Do not hurry to repair the scale body or instrument Repai...

Page 13: ...ements 13 It has enters menu setting Press Print to continue setting 14 End of zero point and loading point calibration 15 Loading default value Appendix 2 Serial port output format Serial port contin...

Page 14: ...13 U S N T sp sp 0 2 0 0 k g 0d 0a Appendix 3 Printing output format LIST Date 2018 04 14 Time 15 08 46 Gross 2 061kg Tare 0 000kg Net 2 061kg LIST Date 2018 04 14 Time 15 10 18 Count 206PCS...

Reviews: