Operation Overview
A pressurized water source is fed to the first pre-filter which is a 5 micron spun poly sediment
filter. The water then passes through the sediment filter to the carbon block filters. Water
passes through the carbon block filters and then on to the membrane filters. Product water
(permeate) from the membrane filters is conveyed to the automatic shutoff valve (ASO).
Product water from the “Out” port on the ASO can then be attached to a tank or point of use.
Waste water (concentrate) from the membrane is conveyed to the flow restrictor. The water
leaving the flow restrictor is conveyed to an onsite drain.
Operating Parameters
Operating Parameters
Feed Water Requirements
**If any of the feed water parameters are not within the limits given, consult US Water Systems for assistance.
Operation Overview and Parameters
Feed Temperature
40 - 85°F
System Inlet Pressure
30 - 80 PSIG
Maximum Operating Pressure (@77°F)
100 PSIG (Nominal)
Maximum SDI Rating
< 3
Maximum Turbidity
1 NTU
Maximum Free Chlorine and/or Chloramines
0 PPM
pH (continuous)
3 - 11
Hardness
< 1 GPG
Iron
<0.3 ppm
Manganese
<0.05 ppm
Total Dissolved Solids (TDS)
<1000 ppm
NOTE: HIGHER TDS AND/OR LOWER TEMPERATURES WILL
REDUCE THE SYSTEM’S PRODUCTION. 2% OF THE SYSTEM
OUTPUT CAN BE LOST FOR EVERY DEGREE “F” BELOW 77.