Turn off power to the light pole at circuit breaker.

 

ASSEMBLY PROCESS

 

 

Unbox the QDXLE1 from the packaging.   

Determine the type of mount, Arm Mount, Slip Fitter, or Trunnion.   

 

 

The installation must only be performed by a licensed electrician.

 

To prevent death, injury or damage to property, this product must be installed in accordance to National 
Electrical Code (NFPA70) in the US or Canadian Electrical Code (CSA22.1) in Canada.

 

Disconnect power before installing the product or servicing it.

 

Wait until fixture has cooled down before installing or servicing the fixture. 

Water in the fixture voids warranty.

 

MIN. 90°C SUPPLY CONDUCTORS

 

Read and follow installation instructions. Improper installation will void warranty.

 

3

 

2

 

1

 

Summary of Contents for QDXLE

Page 1: ...on The installation must only be performed by a licensed electrician To prevent death injury or damage to property this product must be installed in accordance to National Electrical Code NFPA70 in the US or Canadian Electrical Code CSA22 1 in Canada Disconnect power before installing the product or servicing it Wait until fixture has cooled down before installing or servicing the fixture Water in...

Page 2: ... and Square Flat Pole DYF1 A Drill necessary holes into pole for fixture mounting B Remove pole cap and lower nut plate inside of pole until threaded holes align with proper mounting holes C Affix Arm Mount to pole using nut plate bolts lock washers and nuts D Remove side plate of Arm Mount E Fish power leads from pole into Arm Mount F Mount QDXLE1 onto Arm Mount G Make electrical connections with...

Page 3: ...WEST DR HOUSTON TX 77024 T 866 972 9191 F 713 972 9393 info usled com www usled com Slip Fitter Mount DYS1 A Fish power cable though slip fitter B Attach slip fitter to QDXLE C Make electrical connections in the pole D Insert the slip fitter over the pole E Tighten the screws on the slip fitter ...

Page 4: ... to mounting surface using appropriate hardware supplied by installer B Affix fixture to mount using fixture mounting screws lockwashers washers and nuts C Adjust fixture position angle by removing position locking screw loosening pivot screw rotating to designated position tighteningpivot screw and replacing locking screw FIG 4 D Run power to the Dorado back housing using a liquid tight conduit f...

Reviews: