4
How to calibrate
1.
Before entering calibration mode, press [ON/OFF] to turn the power
on for 1 minute.
2.
Press [
COUNT/CAL
] Key for 3 seconds and release the
[
COUNT/CAL
], the display will show flash calibration weight.
3.
Place the calibration weight on platform, Wait for 5 seconds, the
display will show “…….” Then it will return to weight value. Now
calibration is complete.
4.
Press [
ON/OFF
] to turn the power off, press [
ON/OFF
] to turn the
power on again, place the full weight on the platform to make sure
whether weight is correct, if not, repeat step 2~4.
5.
Return the weighing mode
Press [
ON/OFF
] to turn the power off, Press [
ON/OFF
] again to
turn on the power and the scale/balance return to the weighing mode.
SPECIFICATIONS
Model number
Capacity
Division
US-TRADER-PRO 3Kg
3000g
0.1g
Platter
145 x 145 mm
Net/gross weight
920g / 1300g
Package
Standard carton : 23.5 x 14.5 x 29.5 (cm
3
)
6 Units in one Box : 50.5x 32.5x48.5(cm
3
)
Operating
Temperature
0-40C (32-104F)
Power source
6 x AA Size Batteries or AC/DC
Adapter 9V/100mA
•
Auto shut off (selectable)
FEATURES
•
Auto zero tracking
•
Low battery indication
•
1/2000&1/30000 division
available
•
Large container weighing
•
Auto calibration
•
Large LCD
•
Kg/g/lb/lb:oz/oz conversion
•
Auto Backlight (selectable)
Counting procedures
1.
Press [ON/OFF] to turn on the scale
, Wait for ‘0” to appear on the
display.
2.
Start the Count Procedure
If necessary press [
ZERO
] key to set the display to “0”.
3. Place a given number of samples of an item on the pan (the Sample Size
should be either 10, 20, 50 or 100 pieces). The weight of these samples will
show on the display. Press the [
PCS]
key to put the scale in PCS mode, the
display will show P=X X, press [
UNIT
] to select XX value (10 ,20, 50, 100),
4. Press the [
PCS
] key, the display will show PASS then “XX ‘, then the
scale will recall the sample size you selected and show the starting sample
size on the display (you can now remove the samples if you want to return
the scale to 0)
5. Press the [
UNIT
] key to return to the weighing mode
Counting Procedures
FUNCTION SETTINGS
1.
Enter function setting mode.
Press [
ON/OFF
] to turn the power off, Press [
COUNT/CAL
] first, then
press [
ON/OFF
], while keeping [
COUNT/CAL
] pressed, the display will
show
A_ON
or
A_OFF
.
2.
Selection of auto backlight mode.
When the balance enter function setting menu, Press [
UNIT
] key, the display
will show
L_ON
or
L_OFF
, press [
COUNT/CAL
], selection display L_ON,
this means auto backlight function active, press [
COUNT/CAL]
again, the
display will show
L_OFF
, this means auto backlight function inactive, i.e.
shut off backlight function.
3.
Selection of auto shut off mode.
When the balance enters function setting menu, Press [
UNIT
] key, the
display will show
A_ON
or
A_OFF
, press [
COUNT/CAL
], selection
display A_ON, this means auto shut off function active. Press
[
COUNT/CAL
] again, the display will show
A_OFF
, this means auto shut
off function inactive.
4.
Return to weighing mode.
Press [
ON/OFF
] to turn the power off, press [
ON/OFF
] again to turn on the
power and the scale return to the weighing mode.