Page 1: ......
Page 2: ...OTAA 16 3 4 2 Basic ABP 19 3 4 3 Channel 21 3 5 Upgrade 22 4 Configuration via Ursalink Cloud 23 4 1 Account Setup 23 4 2 Add a Ursalink LoRaWAN Gateway 24 4 3 Add Devices to Ursalink Cloud 25 4 4 Check the Data of UC11 N1 28 4 5 Configure UC11 N1 via Ursalink Cloud 29 4 5 1 Basic Settings 29 4 5 2 Interface Settings 30 5 Configuration via TTN 32 5 1 Add UC11 N1 to The Things Network 32 5 1 1 Crea...
Page 3: ...trial automation building automation and smart agricultural applications to provide network capability in remote or factory floor environments It can also connect 4 20mA 0 10V analog devices the most commonly deployed devices in industrial environments This user guide is intended to provide detailed technical specifications and explanations to basic users as well as the technically minded groups I...
Page 4: ...pported in N1 DC Serial Port Ports 1 RS232 or RS485 Switchable Baud Rate bps 1200 2400 4800 9600 57600 115200 Protocol Transparent RS232 Modbus RTU RS485 Analog Input Ports 2 Analog input Resolution 12 bit Input Range 4 20mA or 0 10V Switchable Power Output Ports 2 3 3 V 2 5 9 12 V Switchable Configuration Interface Ports 1 USB Physical Characteristics Operating Temperature 20 C to 70 C Ingress Pr...
Page 5: ...wer Connector DC version M12 A Coded 4 pin Male 2 3 Terminal Description 2 4 Turn on off the Device Put a magnet close to the reed switch to turn on or turn off the device Buzzer rings for 2 seconds power on Buzzer rings for 6 seconds power off ...
Page 6: ...ox Serial Port Settings Item Description Default Serial Port Select the serial port for data transmission Null Login Password Enter the correct password to login 123456 Baud Rate Select from 9600 57600 115200 57600 Data Bit Select from 5 7 8 8 Parity Bit Select from Even Odd None None Stop Bit Select from 1 2 1 If the serial port parameter is correct it will display Serial port is connected ...
Page 7: ...7 3 2 Status Click Status to see the basic status information of this device 3 3 General 3 3 1 Basic ...
Page 8: ...e 30 86400 s 1200 Interface 1 Pin2 3V3 Output Enabled UC11 N1 will provide power to device connected to Interface 1 pin2 Voltage is 3 3V Disabled Interface 2 Pin2 3V3 Output Enabled UC11 N1 will provide power to device connected to Interface 2 pin2 Voltage is 3 3V Disabled Change Password Enable Change Toolbox login password Disabled 3 3 2 Serial RS485 Modbus Master On this page you can enable the...
Page 9: ...elect from 1200 2400 4800 9600 57600 and 115200 9600 Data Bits Select from 5 7 8 8 Stop Bits Select from 1 2 1 Parity Bits Select from Even Odd None None Data Polling Interval Set the interval for reading remote channels When the reading cycle ends the new reading cycle begins until this interval over If it is set to 0 the device will restart the new reading cycle after all channels have been read...
Page 10: ... UC11 N1 and Network Server Range 2 84 86 223 Null Channel Settings Item Description Default Channel ID Assign the channel for the slave device 8 channels selectable Null Name Set the name to identify the remote channel It cannot be blank Null Slave ID Set Modbus slave ID Null Address The starting address for reading Null Quantity Set read how many digits from starting address Null Type Read comma...
Page 11: ...m this slave device Null Fetch Click to read the data from this slave device Null RS232 Settings Item Description Default Enable Enable Disable serial interface Enable Interface Type Set the interface type Select from RS485 Modbus Master and RS232 RS485 Modbus Master Interface 1 Pin 1 5v 9v 12v Output Enable UC11 N1 will provide power to the device that connected to Interface Disabled ...
Page 12: ... set 100ms then before collecting data from end nodes UC11 N1 will provide power for end nodes for 100ms Range 1 5000 ms Note With this feature being enabled the power consumption will increase None Baud Rate Select from 1200 2400 4800 9600 57600 115200 9600 Data Bits Select from 5 7 8 8 Stop Bits Select from 1 2 1 Parity Bits Select from Even Odd None None ...
Page 13: ...Click to enable this interface Disable Interface Type Choose from Digital Input Digital Output Digital Input This GPIO will be used as Digital Input Then you will need to select the initial state of this digital input from Pull Up High Pull Down Low Digital Output This GPIO will be used as Digital Output Digital Input Status Show the current status of this interface Click Fetch to fetch the latest...
Page 14: ...ull Down Low Digital Output This GPIO will be used as Digital Output Counter This GPIO will be used as the pulse counter Digital Input2 Keep Last Value when Power Off Enable The device will store the last counter value in the register when the module is powered off Disable Counter Value It will continuously show the present counter value unless it stops Null Refresh Click to refresh the counter va...
Page 15: ...tings Item Description Default Interface 2 Pin 1 5 9 12V Output Enable UC11 N1 will provide power to device connected to Interface 1 pin1 Voltage is 5V 9V or 12V Disabled Power Output Time Before Collect If the time is set to 100ms then before collecting data from end nodes UC11 N1 will provider power for end nodes for 100ms Range 1 5000 ms 1 5000 ...
Page 16: ...Set the interval for reading analog input Range 5 3600 s 5 Interface Name Show the name of this interface Null Enable Click to enable this interface Disable Analog Input Signal Type Select from 4 20 mA 0 10 V 4 20 mA Status Show the current value of this interface Click Fetch to fetch the latest value of this analog input Null ...
Page 17: ... the device to send and receive RS232 data 86 Working Mode Show the working mode of the device UC11 N1 Null UC11 N1 DC Class A Class C Class A Class A operation is the lowest power end device system Class C Class C end device will use more power to operate than Class A but they offer the lowest latency for server to end device communication Class A Join Type Select from OTAA and ABP OTAA Over the ...
Page 18: ... regular report packet to the network server if the device does not receive ACK bit from the network server then the device will resend the packet Note If the device doesn t receive ACK for a long time the device will resend regular report confirmed packets 3 times at most Disabled Alarm Report Confirmed After sending the attribute package or alarm packet or battery packet to the network server if...
Page 19: ...rver receives request and consults the entity associated with the APPEUI to validate the request If permission is granted it responds with a join accept message 24E124C00 02A0001 Application Port The port used by the device to send and receive LoRaWAN data 85 RS232 Port The port used by the device to send and receive RS232 data 86 Working Mode Show the working mode of the device Class A ...
Page 20: ...device address The device address identifies the end device within the current network The last 8 digits number of SN Network Session Key Enter the network session key of the device The network session key specific for the end device It is used by the end device to calculate the MIC or part of the MIC message integrity code of all uplink data messages to ensure data integrity 5572404c6 96e6b4c6f 5...
Page 21: ...ice will resend alarm report packets or battery packets 3 times at most However the device will resend attribute package all the time Disabled 3 4 3 Channel On this page you can view all of the supported LoRa frequencies and setup the channel frequency used for receiving and sending data Note Make sure that you have configured the corresponding channel on the gateway E g If you have configured a 9...
Page 22: ...e file from the PC Step 4 Click Upgrade and the device will check if the firmware file is correct If it s correct the firmware will be imported to the device and the device will reboot after upgrading is completed Note Any operation on Ursalink ToolBox is not allowed during upgrading otherwise the upgrading will be interrupted or even the device will break down ...
Page 23: ...unt with Ursalink Cloud follow these steps 1 Go to https cloud ursalink com login html to register an Ursalink Cloud account 2 Log in to Ursalink Cloud after the email has been verified Note It is important that you have access to the verified email address before proceeding ...
Page 24: ...Gateway and click Add to add a LoRaWAN gateway Enter the correct SN of the gateway and click Add Gateway SN can be found either on the label on the bottom of the device or on the web GUI of gateway Note Gateway mode should be selected as Ursalink Cloud ...
Page 25: ...ce has been added successfully You will see the device in the list 4 3 Add Devices to Ursalink Cloud To add a UC11 N1 to Ursalink Cloud please follow these steps 1 Click to go to the configuration page of this gateway ...
Page 26: ...26 2 Click and then click Associated Devices 3 Click Add to add a UC11 N1 to this gateway 4 Enter the correct SN of the UC11 N1 and then click Add The device SN can be found on the bottom of the device ...
Page 27: ... add UC11 N1 directly to the main page please follow these steps 1 Click Add on the upper left corner 2 Enter the correct SN of UC11 N1 and select the correct gateway to which this UC11 N1 will be added Then click Add 3 Once the device has been added successfully You will see the device in the list ...
Page 28: ...28 4 4 Check the Data of UC11 N1 Click LoRaWAN Network Server Packets to view the data transmission You can see the basic status of the UC11 N1 on the Ursalink Cloud main page ...
Page 29: ...plication Key Enter the application key Whenever an end device joins a network via over the air activation the application key is used for derive the Application Session key 5572404c6 96e6b4c6f 526132303 13823 Description The description of the device Reporting Interval The interval of sending data to Ursalink Cloud 20min Device Offline Alarm The device will send an alert if disconnected Enabled L...
Page 30: ...how the name and the type of this interface GPIO x Digital Input x Custom Name Enter the custom name of this interface GPIO 1 Value Show the latest value of this interface Null Visualization Enable The interface s name and value will be shown on the home page Disable The interface s name and value will not be shown on the home page Disable Note Before checking AI data on Ursalink Cloud you need to...
Page 31: ...ame and value will be shown on the home page Disable The interface s name and value will not be shown on the home page Disable The following variables are pertinent to the scaling formula Ov scaled output value Iv analog input value Osh high limit of the scale for the scaled output value Osl low limit of the scale for the scaled output value Ish high limit of the scale for the analog input value I...
Page 32: ...plication and users are only able to access data from devices registered to their account Channel Settings Item Description Default Channel ID Assign the channel for the slave device 8 channels selectable Null Channel Name Set the name to identify the remote channel It cannot be blank Null Type Read command options are Coil Discrete Holding Register INT16 Input Register INT16 Holding Register INT3...
Page 33: ... application follow these steps 1 Click APPLICATIONS located on the Console page 2 Click add application 3 Fill in the information of Application Handler Registration is the same as previous in Gateway registration ...
Page 34: ...er Devices in the application overview page 2 Enter the Device ID This ID must be unique on the user s account We recommend using the convention dev for device followed by the device Dev EUI For instance if the device has a Dev EUI of 0025ca000000000f then the Device ID is dev 0025ca000000000f 3 Enter the Device EUI App EUI and App Key of UC11 N1 ...
Page 35: ...35 4 Click Register to complete registration 5 1 3 Configure UC11 N1 Connect UC11 N1 to PC and configure it via Toolbox ...
Page 36: ...36 5 2 Check Data Transmission on The Things Network 1 Click Gateways to check the Gateways status 2 Click Applications and select the Applications then go to Data you can find the data from UC11 N1 End ...