TROUBLESHOOTING GUIDE

TROUBLES

POSSIBLE SOLUTIONS 

•  Jack will not operate
•  Ram lowers under load

•  Make sure the release valve is closed.  Check release valve.

•  Jack will not operate
•  Ram lowers under load 
•  Handle moves when jack is 

under load

•  Valves may be blocked or may not be fully closed. To Flush Valves:  

1.  Lower the saddle and close the release valve. 
2.  Manually lift the saddle several inches.  
3.  Open the release valve and force the saddle down as quickly as possible.

•  Jack will not operate 
•  Ram will not lift all the way
•  Pump stroke feels spongy

•  Jack may be low on oil. Check and refill if needed.

•  Jack may require bleeding the air out of the system.

•  Oil leaks from oil plug

•  Unit may have too much hydraulic oil inside.  Check fluid level.

PART LIST

#

Description

Qty

#

Description

Qty

#

Description

Qty

1

Angle Steel Feet

2

12

Hook

2

23

Nylon Lock Nut M5

1

2

Main Frame

2

13

Wing Nut

2

24

Hex Bolt M8x20

9

3

Connecting Plate

4

14

Tension Spring

2

25

Nylon Lock Nut M8

9

4

Spreader

1

15

Hex Bolt M12x105

4

26

Hex Bolt M12x30

4

5

Handle Base

1

16

Press Plate

2

27

Nylon Lock Nut M12

4

6

Press Platform

2

17

Upper Crossbeam

1

28

Pressure Gauge

1

7

Support Rod

2

18

Bottle Jack

1

29

Copper Sheet B

1

8

Handle

1

19

Plastic Clip

1

30

Elbow

1

9

Stud

2

20

Hexagon Socket Head Cap Screw M8x20

2

31

Copper Sheet A

1

10

Nylon Lock Nut M16

8

21

Lock Washer Ø8

2

32

Connector

1

11

Jack Plate

1

22

Hex Bolt M5x16

1

Summary of Contents for 24703

Page 1: ...eguridad contenidas en este documento antes de operar esta herramienta WARNING Read understand and follow the safety rules in this document before operating this tool Prensa Hidr ulica Hydraulic Press...

Page 2: ......

Page 3: ...met licas pintadas INSTRUCCIONES DE SEGURIDAD ADVERTENCIAS Aseg rese de leer comprender y aplicar las instrucciones y advertencias de seguridad antes de operar la prensa Las advertencias precauciones...

Page 4: ...perno hexagonal M12x30 26 y una tuerca de bloqueo de nylon M12 27 Coloque la placa de conexi n 3 a la base principal 2 con un perno hexagonal M8x20 24 y una tuerca de seguridad de nylon M8 25 Una el...

Page 5: ...ije la placa del gato con el marco principal Nota la direcci n de la flecha en el gato hidr ulico est en el lado frontal Fije el gato de botella 18 a la placa del gato 11 usando un tornillo hexagonal...

Page 6: ...puede requerir una purga de aire en el Sistema Perdida de aceite a partir del tap n El gato puede tener un nivel de aceite superior al requerido cheque y nivele si es necesario Descripci n Cant Descr...

Page 7: ...ructions and warning before use The warnings cautions and instructions discussed in this manual cannot cover all conditions and situations that may occur It must be understood by the operator that com...

Page 8: ...d angle steel feet 1 to the main frame 2 using hex bolt M12x30 26 and nylon lock nut M12 27 Attach connecting plate 3 to the main frame 2 using hex bolt M8x20 24 and nylon lock nut M8 25 Attach the ot...

Page 9: ...ow on the jack plate is front side Attach the bottle jack 18 to the jack plate 11 using inner hex bolt M8x20 20 and lock washer 8 21 Note Attach the bottle jack must be handled with care so as not to...

Page 10: ...eeded Jack may require bleeding the air out of the system Oil leaks from oil plug Unit may have too much hydraulic oil inside Check fluid level PART LIST Description Qty Description Qty Description Qt...

Page 11: ......

Page 12: ...casos a Cuando la herramienta se haya utilizado en condiciones distintas a las normales b Cuando el producto hubiera sido alterado de su composici n original o reparado por personas no autorizadas po...

Reviews: