You can create the GPRS connection in the following two ways: 

 

1. 

Creating the connection manually. 

 

Double-click  the 

Network  and  Dial-UP Connection 

icon  on  the  control 

panel to enable the network and the dial-up connection manager. 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Click 

New Connection

connection. 

Summary of Contents for i3000

Page 1: ...1 User Manual for UROVO i3000...

Page 2: ...eserved Except the part permitted by the Copyright Law of the People s Republic of China no contents shall be duplicated reproduced modified or translated in whole or in part without written consent o...

Page 3: ...aultSettings 28 CalibratingtheScreen 29 CheckingtheRemainingElectricity 30 PrecautionsforUsingtheBattery 31 Content CONTENT 3 CHAPTER 1 PACKING CONFIRMATION 5 CheckingArticlesContainedinthePackage 5 C...

Page 4: ...9 WarrantyScope 50 WarrantyDeclaration 50 Contact 50 CHAPTER 4 ADVANCED SETTINGS 32 SettingthePowerButtonFunction 32 SettingtheGPRSNetwork 32 SettingtheWi FiNetwork 40 SettingtheOptionsforBarcodeScann...

Page 5: ...r 1 Packing Confirmation Checking Articles Contained in the Package Before using the product please check whether the package contains the following articles Power adapter Battery Connector adapter Da...

Page 6: ...n endure multiple drops to a smooth concrete floor from a height of 1 2 m and resist splashes and dusts in any direction The high capacity and long service life of the battery can fully meet the requi...

Page 7: ...lete feature set and development environment and obtains features of every customized device such as real time small memory usage multimedia and network connecting capability The OS supports multiple...

Page 8: ...oftware interface that can be used to develop application functions 9 The product is an industry level device that is drop proof dustproof and high low temperature resistant 10 High speed and high cap...

Page 9: ...engine type One dimension laser scanner Scanning speed 200 per second bidirectional Scanning distance 60 650 mm Scanning angle 54 5 degree Resolution 0 127 1 00 mm Readable barcodes UPC A UPC E UPC E...

Page 10: ...e CISCO CCX2 3 security standards and supports CISCO AP and security regulations Bluetooth standard configuration Bluetooth V2 1 EDR Wide area wireless network extension The i3000 product provides a G...

Page 11: ...n IP54 Dimensions Ergonomic design 189mm length x 68 mm width x 38 mm thickness Weight 280 g with batteries Working Environment Operating temperature 15 to 50 C Storage temperature 20 to 60 C Operatin...

Page 12: ...rtificate for radio transmission equipment issued by the Ministry of Industry and Information Technology The preceding parameters are for reference only Parameters of a specific model are subject to s...

Page 13: ...13 5 Charging Dock Interface 6 Widow for scanning barcodes 7 Camera 8 Loudspeaker...

Page 14: ...ower on off the device or switch the device into sleep or wake up mode 4 Headphone jack The headphone jack can be inserted with a 3 5 mm headphone 5 Touch screen The touch screen enables you to perfor...

Page 15: ...an input numbers or letters based on the current input mode 4 Function key You can use a key combination by pressing releasing it and then pressing another key 5 Keyboard backlight key You can press t...

Page 16: ...yboard 9 Enter key You can press the Enter key for confirmation or to switch to next line 10 Backspace key You can press to delete the previous character 11 Alphanumeric switching key You can press to...

Page 17: ...aster battery cover buckles are used to fix the battery cover 4 TF card slot A Micro SD TF memory card can be inserted in the TF card slot 5 SIM card slot An SIM card provided by carriers can be inser...

Page 18: ...arately The first charging must be more than 12 hours Powering On Off the Device The i3000 product is powered off when you obtain it for the first time After you press and hold down the power button t...

Page 19: ...yed Select Yes to power off the device During power off the power supply is cut off and data in the memory is lost You can press and hold down the power button again to power on the device Changing Da...

Page 20: ...ist to choose the required time zone Click Apply on the lower right corner of the dialog box to save the configuration Click the number indicating the year to enter a year directly or change the year...

Page 21: ...it in the displayed menu or click the up and down arrows to change the month Click the mapping number in the date area to change the date After the configuration is complete click OK on the upper righ...

Page 22: ...elect text or use the stylus to drag the scroll bar For many applications after you press and hold down an object for about two seconds by using the stylus a context menu is displayed Note You must us...

Page 23: ...us to click the keyboard icon on the taskbar The list of available soft keyboards is displayed on the screen You can choose the required soft keyboard from the list Click Keyboard to display the keybo...

Page 24: ...24 Use the stylus to click the soft keyboard to enter letters numbers or symbols Choose Hide Input Panel to hide the current soft keyboard...

Page 25: ...e upper case mode and lower case mode You can set the default input mode of the master keyboard by choosing Control Panel Keyboard Managing Device Functions Certain functions of the i3000 product are...

Page 26: ...ables disables the function automatically after next power on Scanning Barcodes You can use the ModuleMgr or ScannerSetting program to start the scanner and then press the orange barcode scanning key...

Page 27: ...nnect the device to a PC by using a data line if Microsoft ActiveSync 4 5 Window 2000 XP 2003 or Windows Mobile Device Center 6 1 windows Vista 2008 7 is installed on the PC You can download Microsoft...

Page 28: ...le and release it immediately 2 Cold boot If you restart the device in cold boot mode the power is cut off forcedly Ongoing items are terminated and the device restarts Data in the memory is deleted E...

Page 29: ...eriod the clicking point of the stylus may shift and you must re calibrate the screen Click the stylus icon in the control panel to display the Stylus Properties dialog box Click the Calibrate tab in...

Page 30: ...s point you can press the Enter key to save the calibration Checking the Remaining Electricity You can click the power icon on the control panel to display the Power Properties dialog box When the ele...

Page 31: ...e battery charge and discharge times and charge the battery only when the system displays the electricity insufficiency warning 2 Prevent over discharge in daily use and charge the battery immediately...

Page 32: ...unction is provided when you press and hold down the power button Setting the GPRS Network Enable You can shortly press the power button during power on to switch the device to sleep mode Disable No f...

Page 33: ...ection in the following two ways 1 Creating the connection manually Double click the Network and Dial UP Connection icon on the control panel to enable the network and the dial up connection manager C...

Page 34: ...34 Enter the connection name such as GPRS Select Dial up connection and click Next Choose COM2 or COM3 and then click Configure...

Page 35: ...per second to 115200 On the Call Options tab page enter the following command to initialize the modem CGDCONT 1 IP cmnet Cmnet specifies the point to connect to the GPRS network of China Mobile Click...

Page 36: ...the Phone Number area enter the dial up number such as 99 1 You must query the mobile carrier to obtain this number Click Finish Double click the created GPRS connection to display the Dial Up Connec...

Page 37: ...37 Click Dialing Properties to set the dialing location Click Create to enter the new location name such as GPRS...

Page 38: ...38 Click Edit to change the dialing mode Change the texts in the three text boxes to G and then click OK to save the settings and exit...

Page 39: ...y To simplify the setting of GPRS connection the device provides the GPRSSetting tool to set the connection quickly Choose My Device Windows and click the GPRSsetting icon to enable the GPRSsetting to...

Page 40: ...nction manager ModuleMgr You can query the network administrator for the wireless network information such as SSID encryption type authentication mode and cipher key Click the network icon on the task...

Page 41: ...h the broadcast function is enabled Double click the SSID to be connected If the broadcast function is not enabled for the AP to be connected double click the Add New Network icon When you add an avai...

Page 42: ...ect to another device or PC The encryption type varies with the authentication mode Select the correct authentication mode first Click Advanced to display the interface for advanced settings If a stat...

Page 43: ...con is displayed only when the Wi Fi function is enabled Use the stylus to click and hold down the icon and choose Properties in the displayed context menu Enter the IP address subnet mask and default...

Page 44: ...ptions to display the interface for advanced setting To enhance the decoding speed the decoding function is disabled for certain types of barcodes by default You can enable the decoding function manua...

Page 45: ...y using programs not supporting barcode scanning including the Wordpad and remote desktop programs On the Output tab page you can select the displayed options to send messages after bar code scanning...

Page 46: ...us before delivering the device in order to obtain service information delivery instructions and maintenance costs maintenance irrelevant to the warranty Service If you require diagnostic services or...

Page 47: ...lude data line connector adapter stylus battery power adapter and handheld elastic strap Based on normal operating conditions if you find any quality defect within seven days from the purchase date yo...

Page 48: ...warranty applies to mandatory specifications of related national laws Warranty Declaration The Company provides this unique warranty statement for the product without other written or oral warranty st...

Reviews: