urmet domus ELKRON IR600FC/RF Quick Manual Download Page 3

 

 

ENGLISH

 

IR600FC/RF 

INDOOR INFRARED DETECTOR WITH CAMERA 

 

1. Illuminator 
2. Blue LED/Function button 
3. IR sensor lens 
4. Camera lens  
5. Battery compartment lid 

6. Tamper switch  
7. Battery compartment 
8. Jumper JP3 PIR sensitivity 
9. Jumper JP2 
10.  Fastening screw 

LED 

The blue LED lights up in the following conditions:  
-  When the PIR Camera is in low battery condition, every time it transmits a detected movement, the Blue LED will flash for 2 

seconds. 

-  When the cover is opened and the tamper switch is violated, the Blue LED will flash for 2 seconds, to indicate it is transmitting 

“Tamper” signal. 

-  When the Tamper condition persists, every time it transmits a detected movement, the Blue LED will flash for 2 seconds. 
-  When PIR Camera enters Test Mode, the Blue LED will flash for 1 second. During Test mode, the Blue LED will also flash for 

2 seconds every time a movement is detected. 

-  When the PIR Camera is in 30 seconds warm up period, the Blue LED will slow flash. 
-  When the PIR Camera is transmitting captured images under fault conditions (low battery, tamper switch activated), the Blue 

LED will continuous flash. 

Using the function button: 

-  Press the button once to send a supervision signal. 
-  To reset the detector: hold the button pressed for 10 seconds. Release the button when the illuminator and the blue LED blink 

once. 

-  For the learning procedure of the detector on the control unit 

Jumper JP3 PIR sensitivity 

-  Jumper on: "High" sensitivity level. 
-  Jumper off: "Normal" sensitivity level (default setting). 

Jumper JP2  

-  Jumper On: after transmitting following a detected movement, the signals and the acquired images will be transmitted 

if any other movements are detected (default setting). 

-  Jumper Off: the detector has a “sleep time” (see below) of approximately 1 minute to save energy.  

SLEEP TIME 

 

time that elapses between the transmission of a movement and the next transmission

 

Test mode 

The  Test mode is used to control the detection coverage of the  device not the communication range with the control unit. To 
access Test mode: hold the function button pressed for five seconds. The blue LED will light up and stay on for approximately 30 
seconds after having released the button. Test mode, which lasts for 3 minutes, will start after this time. 

 

The detector will start initialisation during the first 30 seconds. The detector does not manage intrusions or movements 
during this time. 

 

Motion detection in front of the detector can be checked at the end of the initialisation period. The blue LED lights up for 
two seconds after detection. 

 

 

 

QUICK GUIDE 

DS80IR9E-002 

10 

Summary of Contents for ELKRON IR600FC/RF

Page 1: ...el rivelatore sull unit di controllo JUMPER JP3 SENSIBILIT DEL PIR Jumper On livello della sensibilit Alta Jumper Off livello della sensibilit Normale impostazione di default JUMPER JP2 Jumper On dopo...

Page 2: ...TECNICHE Banda radiofrequenza 868 600 868 700MHz Potenza radio massima trasmessa 9 69dBm DICHIARAZIONE DI CONFORMIT UE SEMPLIFICATA Il fabbricante URMET S p A dichiara che il tipo di apparecchiatura...

Page 3: ...signal To reset the detector hold the button pressed for 10 seconds Release the button when the illuminator and the blue LED blink once For the learning procedure of the detector on the control unit...

Page 4: ...oles on the corner bracket 2 Using the two holes as template drill the holes corresponding to the surface 3 Insert the anchor bolts if the device is fixed to plaster or bricks 4 Screw the bracket into...

Page 5: ...ispositif d clairage et la LED bleue clignotent une fois Pour l apprentissage du d tecteur sur l unit de contr le Cavalier JP3 sensibilit du PIR Cavalier On niveau de sensibilit lev Cavalier Off nivea...

Page 6: ...a base dans les chevilles 6 Repositionner le cache sur la base Montage angulaire 1 Percer les orifices en suivant les pr dispositions pr sentes sur l trier angulaire 2 Utiliser les deux orifices en gu...

Page 7: ...einem Steuerger t Jumper JP3 Empfindlichkeit des PIR Jumper On Empfindlichkeitsniveau Hoch Jumper Off Empfindlichkeitsniveau Normal Standardeinstellung Jumper JP2 Jumper On nach der bertragung im Ansc...

Page 8: ...z oder Ziegel die D bel einsetzen 5 Die Basis in den D beln verschrauben 6 Die Abdeckung wieder an der Basis anbringen Montage in einem Winkel 1 Die f r die Bohrungen vorgesehenen Bereiche auf der Win...

Reviews: