8

DS1375-023

3  CONNECTION INSTRUCTIONS

•  Connect the CAT5/CAT5E wire to one of the RJ45 connectors with Urmet logo.

•  Insert the wire in the guide respecting the colour coding shown (Standard T568B).

8

1

Wire

No.

Wire colour

1

White-Orange

2

Orange

3

White-Green

4

Blue

Wire

No.

Wire colour

5

White-Blue

6

Green

7

White-Brown

8

Brown

•  Cut the wires which protrude from the guide by approximately 5mm, insert the guide in the plug and 

crimp the plug with a specific tool.

Plug

8

1

~ 5 mm

8

1

 

• 

 Make sure that the grey sheath remains inside the plug.

  This type of connection DOES NOT ensure double insulation.

  Wires with cross-section area of 0.5 mm

2

 or larger must comply with IEC 60332-1-2; wires with 

cross section area smaller than 0.5 mm

2

 must comply with IEC 60332-2-2.

  Refer  to  the  instructions  contained  in  the  iPerTAlk  installation  and  configuration  manual  for 

maximum distances and configuration operations.

4  TECHNICAL SPECIFICATIONS 

Power voltage and consumption on terminals V+ e V-

Power voltage: ...............................................................................................................................

44 – 57 V

Consumption video call @48V:

 .............................................................................................................

160 mA

Consumption stand-by @48V:

 .............................................................................................................

100 mA

Working temperature range: ..................................................................................................

-10 °C ÷ +50 °C

Relay contact range C, NC, NO:

Maximum switching voltage:  ....................................................................................................................

30 V

Maximum switching current:  ...................................................................................................................

3,5 A

Maximum switching load: .............................................................................................................

40 VA 25 W

Garage gate relay contact range (SE2):

Maximum switching voltage:  ....................................................................................................................

30 V

Maximum switching current:  ...............................................................................................................

200 mA

Max. distance from hall button: 

 .............................................

25 m with cable cross-section area 0.5 mm

2

Max. distance from open door sensor:  .................................

50 m with cable cross-section area 1.5 mm

2

Max. distance from supplementary power supply:  .............

100 m with cable cross-section area 1.5 mm

2

Max. distance from capacitance lock:  ................................

100 m with cable cross-section area 1.5 mm

2

Summary of Contents for elekta 1375/823

Page 1: ...DS 1375 023 LBT 20764 Mod 1375 MODULO DI CHIAMATA ELEKTA ELEKTA CALL MODULE Sch Ref 1375 823...

Page 2: ...prossimit a infrarossi per il rilevamento dell utente Telecamera CCD a colori con obiettivo grandangolare Tastiera alfanumerica a 18 tasti di cui 3 multifunzione Estetica in vetro nero 2 INSTALLAZION...

Page 3: ...ontatto normalmente chiuso del rel serratura SE Morsetti elettroserratura a scarica SE PA Morsetti pulsante androne per pilotaggio e serratura rel SP Morsetti Sensore porta aperta SE2 Morsetti contatt...

Page 4: ...se di sezione inferiore a 0 5 mm Per le massime distanze e per le operazioni di configurazione si raccomanda di seguire le regole prescritte nel libretto di installazione e configurazione di iPerTAlk...

Page 5: ...ulizia periodica mediante prodotti adatti alle superfici metalliche Evitare l utilizzo di prodotti chimici aggressivi es solventi ammoniaca soda etc 7 LEGENDA SIMBOLI Simbolo Spiegazione Tensione di a...

Page 6: ...or and POE power Set up by means of 2 terminals for local power supply 125 kHz integrated transponder key reader future implementation Infrared proximity sensor for user detection CCD colour camera wi...

Page 7: ...lock relay contact NC Normally closed lock relay contact SE Discharge lock terminals SE PA Hall button terminals for operating lock relay SP Open door sensor terminals SE2 Garage gate contact termina...

Page 8: ...m2 must comply with IEC 60332 2 2 Refer to the instructions contained in the iPerTAlk installation and configuration manual for maximum distances and configuration operations 4 TECHNICAL SPECIFICATION...

Page 9: ...push button panel looking good in time Do not use aggressive chemical products e g solvents ammonia soda etc 7 KEY TO SYMBOLS Symbol Description Direct input voltage See the installation manual of the...

Page 10: ...avvio successivo dell apparecchiatura dismessa al riciclaggio al trattamento e allo smaltimento ambientalmente compatibile contribuisce ad evitare possibili effetti negativi sull ambiente e sulla sal...

Page 11: ...11 DS1375 023...

Page 12: ...T 20764 Area tecnica servizio clienti 39 011 23 39 810 http www urmet com e mail info urmet com MADE IN ITALY URMET S p A 10154 TORINO ITALY VIA BOLOGNA 188 C Telef 39 011 24 00 000 RIC AUT Fax 39 011...

Reviews: