6.2. CONTROLS AND DISPLAYS FOR CONFIGURATION
The con
fi
guration and the respective set values are displayed by means of:
LED (1)
for programming, as shown below:
LED reference
A
B
C
LED colour
Red or Green
Orange
Red or Green
Symbol on front
LED (4)
:
LED for displaying the set parameter value;
BUTTON (5)
:
button for changing and/or con
fi
rming the parameter
PROGRAM button (8)
:
button for starting the con
fi
guration.
See the “Structure” chapter for the location of these components on the door unit.
6.3. READING/CONFIGURATION SEQUENCE
Each parameter is associated with a colour of the LEDs (1) for programming and the set value is indicated
by the LED (4) as follows:
LED (4): OFF
LED (4): ON STEADY
LED (4): ON BLINKING
The steps for reading or con
fi
guring the device are shown below:
1. Press the PROGRAM button (8) brie
fl
y (less than 2s): the LEDs (1) will blink on the door unit [A: red, B:
orange, C: red] to indicate that the device is in programming mode.
2. Press the BUTTON (5) again brie
fl
y to select the parameter to be con
fi
gured which can be identi
fi
ed by
the LEDs associated with it according to the table shown in the following chapter.
3. Select the parameter and hold the BUTTON (5) pressed for longer (from 5 to 10 seconds) to set the
parameter as indicated visually by the LEDs (4).
4. Press the PROGRAM button (8) brie
fl
y or wait for the timeout after 10 minutes to end con
fi
guration
mode.
6.4. PARAMETER ASSOCIATED TO PROGRAMMING LED (1)
COLOUR
Parameter to be con
fi
gured
LED (1)
Parameter value
LED state (4)
Parameter 1: door unit type
LED
C
: Green
Main
LEDs off
Secondary
LEDs on steady
Parameter 2: door unit ID
LED
C
: Red
Address 0
LEDs off
Address 1
LEDs on steady
Parameter 3: door opener
LED
B
: Orange
Privacy
LEDs off
Free
LEDs on steady
Parameter 4: call button enabling LED
A
: Green
No button enabled
LEDs off
Only the calling button (7)
is enabled
LEDs on steady
Both buttons are enabled LEDs on blinking
Parameter 5:
(*)
call button
association with
switchboard call
LED
A
: Red
Not active
LEDs off
Arm
LEDs on steady
(*)
Function only possible if door unit is con