DS1067-063D
53
LBT20064
5.3
PREPARING THE 1067/024 - 1067/032A CONTROL PANEL
IMPORTANT!
During installation of the control panel, be very careful to not accidentally damage the mother
board.
5.3.1
Opening the cover
To open the 1067/024 or 1067/032A control panel cover use the Allen wrench provided for the purpose to unscrew the
two screws (Genia
®
Figure 15 - Opening the 1067/024 - 1067/032A control panel
5.3.2
Openings for cables
The figure below illustrates all the set-up for running the cables (power supply, bus, signalling detectors and devices,
potential telephone line) of the 1067/024 or 1067/032A control panel.
Figure 16 - Set-up for running cables
The set-up for running the cables are:
A
- for embedded corrugated tube;
B
- for rectangular wall duct;
C
- for rectangular wall duct or rigid tube;
D
- for corrugated tube dedicated to the 230 Vac power supply.
F
– points for anchoring cables with bands.
F
F
Summary of Contents for 1067/024
Page 118: ...DS1067 063D 118 LBT20064...
Page 119: ...DS1067 063D 119 LBT20064...